29
MODEL: eXperience 620
F3
AC250V 2.5A
REPLACING THE FUSES
TO REMOVE:
1. Remove the front covers (see page 8).
2. Remove the printed circuit board "A". Remove the four setscrews and remove the cover from the
printed circuit board "A".
3. Remove the fuse (pry up the fuse with a screwdriver).
NOTE:
1. Replace the printed circuit board "A" if you notice any browning, discoloration, or other
abnormalities.
2. Only install fuses with the correct rating.
If the fuse is loose, bend the fuse clips inward to secure the fuse.
FUSE NO.
F2, F3
F1
MANUFACTURE
WALTER
ELECTRONIC
WALTER
ELECTRONIC
DESCRIPTION
TSD-2.5A-250V
5.2 x 20 mm 2.5A PART # 000144605
TSC-3.15A-250V
5.2 x 20 mm 3.15A PART # 000182904
F1
AC250V 3.15A
F2
AC250V 2.5A
Printed circuit board "A"
Setscrews (4)
Printed circuit
board "A" cover
Fuse holder
Fuse