37
Mechanical adjustment
Automatic presser foot lifter initializing position
To adjust:
1. Remove the top cover.
2. Turn the power switch ON while pressing the Start/
Stop button and the Reverse stitch button. The LCD
shows the Factory Setting Mode.
Press "Foot Sensor" key.
3. Turn the gear A (indicated with black arrow) with your
hand to raise the presser foot.
4. Place a 13 mm thick spacer between the presser foot
and the needle plate. Lower the presser foot on the
spacer firmly by turning the gear A.
5. Be sure that the both Sensors 1 and Sensor 2 show “H”.
Press “Start” key on the touch panel.
* In case either Sensor 1 or Sensor 2 is not “H”, turn
the adjusting screw (indicated with white arrow)
clockwise until the both Sensor 1 and Sensor 2
show “H”.
6. Turn the adjusting screw counterclockwise until a beep
sound and the "OK" message is shown.
A