35
Mechanical adjustment
Presser foot lifter stopper position (1)
The distance between the presser foot spring release base and the presser foot lifter should be in the range of 39.4
mm to 39.8 mm when the presser foot is raised with the presser foot lifter.
Preparation:
1. Turn the power switch ON. Press the presser foot lifter
button to lower the presser foot. Turn the power switch
OFF.
2. Raise the presser foot with the presser foot lifter.
3. Remove the top cover (see page 2).
39.4 to 39.8 mm
Presser foot lifter stopper
Presser foot spring
release base
Setscrew B
Setscrew F
Setscrew A
Carrying handle
supporter (front)
Setscrew D
LED cover
(unit)
4. Disconnect the connector from the face cover.
Loosen the setscrew A.
Remove the setscrews B and C.
Remove the carryin handle supporter (front).
Needle bar
supporter spring
5. Remove the setscrew D and the LED cover (unit).
Remove the needle bar supporter spring.
Loosen the setscrew E.
Remove the setscrews F and G.
Remove the front bracket (unit).
Front bracket (unit)
Setscrew C
Connector
Setscrew G
Setscrew E
View from
the front side