9.5.3
Power Supply for the Power Rating 200 V
For Power Rating 200 V, two DC power sources are required, a main power 12 to 195V DC power
source isolated from the Mains, and a control power supply 12 to 95V (isolated from the Mains) for
the logic. The following figure describes the connection of main power and control.
Figure 8: Power Supply Connection Diagram for Power Rating 200V
Note: