Gold Bell Installation Guide
MAN-G-BELIG (Ver. 1.200)
|Connector J2 |
www.elmomc.com
26
Table of Contents
9.5.2
Control Supply
The Control supply is required for the 200V power rating, and can be added for the 100V power
rating.
Note:
The source of the Control Supply must be from the Mains.
Pin
Function
Pin Positions
VL+
Control Supply Input
PR
Control Supply Return
Connector Type: 2 mm pitch 0.51 mm sq
Table 5: Control Supply Pins
Connect the VL+ and PR terminal to the
Control
Connector.
To connect your integration board to the control supply:
1.
The source of the control supply must be isolated from the Mains.
2.
For safety reasons, connect the return (common) of the control supply source to the closest
earth connection near the control supply source
3.
Connect the cable shield to the closest earth connection near the control supply source
4.
Before applying power, first verify the polarity of the connection.