27
www.gd-elmorietschle.com
© Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH
|
Malfunctions: Causes and elimination
Fault
Cause
Troubleshooting
Important
Machine gets too hot
Ambient or intake temperature
is too high
Ensure it is being used prop-
erly
Cooling air supply is ob-
structed
Check environmental condi-
tions
Clean ventilation slots
The lubricating oil is too vis-
cous
The oil viscosity must comply
with ISO VG 32 or 46 as per
DIN ISO 3448
The oil separator element is
dirty.
Change the oil separator ele-
ment
The back pressure is too high
when the exhaust air is being
discharged.
Check the hose or the pipe
Exhaust air contains
visible oil mist
The oil separator element is
not inserted correctly or the O
ring is missing
Check that it is correctly
seated
Unsuitable oil is being used
Use suitable types
The oil separator element is
dirty.
Change the oil separator ele-
ment
Ambient or intake temperature
is too high
Ensure it is being used prop-
erly
Cooling air supply is ob-
structed
Check environmental condi-
tions
Clean ventilation slots
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Tel. 071 918 60 60, Mail: [email protected]