M

AINTENANCE

   

 

There  is  no  regular  maintenance  required  of  the  PSU  other  than  periodic  testing  and  replacement  of  the 
standby batteries.  

Reference should be made to the battery manufacturer’s documentation to determine 

typical/expected battery life with a view to periodic replacement of the battery.   

If the output of the PSU fails the cause of the failure should be investigated e.g. short circuit load.  The fault 
should  be  rectified  before  restoring  power  to  the  PSU.    The  fuses  may  need  to  be  replaced.    Ensure  the 
correct fuse rating and type is used. 

 

 

 

Model Specification Table 

G2401NU 

G2402NU 

G2403NU 

G2405NU 

Output Current 

1A 

2A 

3A 

5A 

Battery Charge Current 

0.5A 

0.5A 

0.5A 

0.5A 

Mains LED (Green) 

 

 

 

 

Fault LED (Yellow) 

 

 

 

 

Max Mains Input Current (at 90Vac) 

1.0A 

1.3A 

1.4A 

2.0A 

F1 - Mains Input Fuse (20mm HRC) 

T2.0A 

T2.0A 

T3.15A 

T3.15A 

F2 - Output Fuse (20mm) 

F1.0A 

F2.0A 

F3.15A 

F5.0A 

F3 - Battery Fuse (20mm) 

630mA 

630mA 

630mA 

630mA 

Содержание G240xNU

Страница 1: ...mode design ensures low operating costs while generating less heat The modular construction simplifies maintenance Universal mains input voltage 90 264vac Additional 0 5A to charge 2 x 12V standby bat...

Страница 2: ...cuit removed under mains power only Local Indicators MAINS LED Green Mains present FAULT LED Yellow Fault present Output or battery fuse fail requires load battery to be connected loss of mains output...

Страница 3: ...ly mounted within a robust enclosure having suitable means to prevent unintentional access to the module Suitable notices must be affixed to the outside of the enclosure to warn of high voltages prese...

Страница 4: ...recommended total battery lead length 500mm 11 Apply mains power Check Green Mains LED is on 12 Check there is no fault indication on Yellow LED 13 Disconnect mains power Check that the batteries con...

Страница 5: ...5 Technical Support 44 0 23 9269 6638 option 3 PAK200566_01B 2016 ELMDENE INTERNATIONAL LTD 128 98 42 4 60 51 84 152 106 12 4 19 13 G2402NU 157 128 7 5 128 42 4 19 60 56 5 4 135 143 12 G2403NU G2405NU...

Страница 6: ...tput of the PSU fails the cause of the failure should be investigated e g short circuit load The fault should be rectified before restoring power to the PSU The fuses may need to be replaced Ensure th...

Страница 7: ...7 Technical Support 44 0 23 9269 6638 option 3 PAK200566_01B 2016 ELMDENE INTERNATIONAL LTD This page has been left blank intentionally...

Страница 8: ...Before disposal of the product the standby battery must be removed and disposed separately via an appropriate approved battery disposal route in accordance with all national and local regulations Pack...

Отзывы: