background image

Page 1

98982C  (Rev. K - 06/16)

VRC8WS, VRC8WSJO, VRCTL8WS, VRCTLR8WS Factory Prep 

EZH2O  Bottle Filling Station and Cooler

INSTALLATION, CARE & USE MANUAL

IMPORTANT

THIS IS AN INDOOR/OUTDOOR APPLICATION.  

ALL SERVICE TO BE PERFORMED BY AN

AUTHORIZED SERVICE PERSON.

Model VRC8WS

Model VRCTL8WS

Model VRCTLR8WS

Buy at

| 855-558-9600 | BottleFillingStations.com

VRCDWS*A, *2A   VRC8WS*1A, *2A, *3A   VRCTLDDWSC*A, *2A   VRCTLRDDWSC*A, *2A VRCTL8WSC*1A, *2A, *3A   VRCTLR8WSC*1A, *2A, *3A

Содержание VRC8WS

Страница 1: ...LATION CARE USE MANUAL IMPORTANT THIS IS AN INDOOR OUTDOOR APPLICATION ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON Model VRC8WS Model VRCTL8WS Model VRCTLR8WS Buy at 855 558 9600 Bottl...

Страница 2: ...COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A METALLI...

Страница 3: ...4 X 1 2 6mm X 13mm OBROUND HOLE 5 PL HANGER BRACKET 7 178mm 7 178mm 16 5 16 414mm 1 1 4 32mm 1 1 4 32mm Single Rough In Fig 1 VRC8WS REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDREN S ADA COOLER LEGEN...

Страница 4: ...mm 7 178mm 1 1 4 32mm 1 1 4 32mm 16 5 16 414mm O 5 16 8mm HOLES 3 PL 5 3 4 146mm 5 3 4 146mm 1 3 8 35mm 1 3 8 35mm 18 1 2 470mm 3 1 2 89mm 4 1 2 114mm 6 1 4 159mm Two Level Rough In Fig 2 VRCTL8WS RED...

Страница 5: ...5mm 5 3 4 146mm 5 3 4 146mm 1 3 8 35mm 1 3 8 35mm 18 1 16 459mm 7 178mm 7 178mm 16 5 16 414mm 1 1 4 32mm 1 1 4 32mm VRCTLR8WS REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDREN S ADA COOLER LEGEND A RECO...

Страница 6: ...s and water inlet Connect black reset button wires from non refrigerated unit to the black wires on the refrigerated unit see step 4 6a For Reversed Two Level Model Installations Secure refrigerated u...

Страница 7: ...Water Cooler The water line and Remote Reset Button Wires will still be connected from the Water Cooler to the Bottle Filler 3 For Two Level Model Installations Loosen but DO NOT remove the Pinned To...

Страница 8: ...back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON REFRIG RST BCNT Res...

Страница 9: ...om below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter...

Страница 10: ...ts Kit Electrical Package 220V Kit Solenoid Valve Replacement 220V Kit Drain Pad Kit Button Assembly Kit Top Cover Replacement Kit Gasket VR BF Tower Basin Kit Reset Switch Kit Micro Switch PART NO EL...