Page 9

98982C  (Rev. K - 06/16)

VERIFY CONTROL BOARD  SOFTWARE

1) To verify the software program of the control board the unit will

need to be shut down and restarted. The chiller (if present) does

not need to be shut down and restarted.

2) The units lower panel must be open to access the power cord and

    wall outlet.

3) Shut down the unit by unplugging the power cord from the wall

outlet.

4)  Restart the unit by plugging the power cord back into the wall

outlet.

5) Upon start up, the bottle count display will show the software

designation of BF11.

6) Reference the BF9 or BF11 instructions for setting the control board

.

ACCESSING THE PROGRAMMING BUTTON

1)   To access the program button remove the top cover of the bottle-

    fille . Remove the two (2) screws holding top cover to bottle-

    filler with a 5/32” allen wrench.  Remove top cove . Do not discard

    mounting screws, they will be needed to reinstall the top cove

 

after 

    programming operations are completed. The programming button 

    is located at the top right side of the unit on the control board.

RESET THE FILTER MONITOR

1) Instructions apply to filtered units onl .

2) Depress the program button for approximately 2 seconds until

the display changes then release. The display will change and

scroll through two messages:

  “RST FLTR” – Reset Filter Monitor

“SETTINGS” – System Settings Sub Menu

If the program button is not pushed again the display will scroll

through the two messages above for three cycles and then default

back to bottle count and be back in run mode.

3) When the display changes to “RST FLTR”, depress the button

again. The display will change to show “FLTR =”. Depress the

button again and the display will show “FLTR =0”

4) The Green LED should be illuminated indicating that the visual

filter monitor has been reset

 SETTING RANGE OF THE IR SENSOR

1) Depress the program button for approximately 2 seconds until

the display changes then release. The display will change and

scroll through two messages:

  “RST FLTR” – Reset Filter Status LED

“SETTINGS” – System Settings Sub Menu

If the program button is not pushed again the display will scroll

through the two messages above for three cycles and then default

back to bottle count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button

again. The display will change to show

“RNG SET” -  Range set for IR sensor.

“UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

“FLT SIZE” - Select filter capacit

“RST BCNT” - Reset bottle count

3)  When display shows “RNG SET” push program button once the

display will show current value (can be 1 – 10) e.g. “RNG = 3”.

4) Once display shows current value push the program button to

scroll through value of 1 – 10. Select the desired range setting,

"1" being closest to sensor and "10" being farthest away.

5) Once range is selected allow approximately 4 seconds to pass and

then the display will go back to bottle counter and be in run mode.

6)  Test bottle filler by placing bottle  r hand in front of sensor to

make sure water is dispensed.

SETTING UNIT TYPE

1) Depress the program button for approximately 2 seconds until the

display changes then release. The display will change and scroll

through two messages:

 “RST FLTR” – Reset Filter Status LED

“SETTINGS” – System Settings Sub Menu

If the program button is not pushed again the display will scroll

through the two messages above for three cycles and then default

back to bottle count and be back in run mode.

Continued from below:

2)  When the display changes to “SETTINGS”, depress the button again.

The display will change to show

“RNG SET” -  Range set for IR sensor.

       “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       “FLT SIZE” - Select filter capacit

       “RST BCNT” - Reset bottle count

3)  When display shows “UNIT TYPE” push program button once the

display will show current value.  Can be REFRIG or NON-RFRG

4) Push button once to change value. Once value is    selected the display

will show the new value.  (Can be REFRIG or NON-RFRG)

 “REFRIG“ - stands for refrigerated product. In this setting the flow rat  is

estimated at 1.0 gallon per minute.

 “NON-RFRG“ - stands for nonrefrigerated product. In this setting the

flow rate is estimated at 1.5 gallons per minute.  Both “REFRIG“ an

“NON-RFRG“ simulate   1 bottle equal to 20 oz.

5)  Allow approximately 4 seconds to pass and the display will return to

bottle counter and be in run mode.

 RESETTING BOTTLE COUNT

1) Depress the program button for approximately 2 seconds until the

display changes then release. The display will change and scroll

through two messages:

 “RST FLTR” – Reset Filter Status LED

 “SETTINGS” – System Settings Sub Menu

If the program button is not pushed again the display will scroll through

the two messages above for three cycles and then default back to bottle

count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button again.

The display will change to show:

“RNG SET”-  Range set for IR sensor.

“UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

 “FLT SIZE” - Select filter capacit

“RST BCNT” - Reset bottle count

If the button is not pushed again the display will scroll through the four

messages above for three cycles and return to run mode.

3)  When display shows “RST BCNT” push program button once the

display will show current value, e.g. “0033183”.

4) Once display shows current value push the program button once more

to reset back to 0. The display will show BTLCT = 0 for approximately 2

seconds and then return to run mode showing 00000000 bottles.

NOTE: Once the bottle count is reset to zero there is no way to

return to the previous bottle count.

5)  Testing the bottle counter:

REFRIG units: Place bottle or hand in front of sensor for approximately

9 seconds to see bottle counter count 00000001,

(This is based on filling a 20 oz. bottle)

NON-RFRG units: Place bottle or hand in front of sensor for

approximately 6 seconds to see bottle counter count 00000001,

(This is based on filling a 20 oz bottle)

 SETTING FILTER CAPACITY

1) Depress the program button for approximately 2 seconds until the

display changes then release. The display will change and scroll through

two messages:

 “RST FLTR” – Reset Filter Status LED

 “SETTINGS” – System Settings Sub Menu

If the program button is not pushed again the display will scroll through

the two messages above for three cycles and then default back to bottle

count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button again.

The display will change to show:

“RNG SET“-  Range set for IR sensor.

“UNIT TYP“ - Type of unit (REFRIG or NON-RFRG)

 “FLT SIZE” - Select filter capacit

“RST BCNT“ - Reset bottle count

If the button is not pushed again the display will scroll through the four

messages above for three cycles and return to run mode.

3)  When display shows “FLT SIZE” push program button once. The display

will show current value. Can be 3000GAL or 6000GAL.

4) Push program button again to display the desired “FLT SIZE”.

5) Allow approximately 4 seconds to pass and the display will return to

bottle counter and be in run mode.

BF11 - BF12 PROGRAM

SETTING THE CONTROL BOARD

Buy at

| 855-558-9600 | BottleFillingStations.com

Содержание VRC8WS

Страница 1: ...LATION CARE USE MANUAL IMPORTANT THIS IS AN INDOOR OUTDOOR APPLICATION ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON Model VRC8WS Model VRCTL8WS Model VRCTLR8WS Buy at 855 558 9600 Bottl...

Страница 2: ...COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A METALLI...

Страница 3: ...4 X 1 2 6mm X 13mm OBROUND HOLE 5 PL HANGER BRACKET 7 178mm 7 178mm 16 5 16 414mm 1 1 4 32mm 1 1 4 32mm Single Rough In Fig 1 VRC8WS REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDREN S ADA COOLER LEGEN...

Страница 4: ...mm 7 178mm 1 1 4 32mm 1 1 4 32mm 16 5 16 414mm O 5 16 8mm HOLES 3 PL 5 3 4 146mm 5 3 4 146mm 1 3 8 35mm 1 3 8 35mm 18 1 2 470mm 3 1 2 89mm 4 1 2 114mm 6 1 4 159mm Two Level Rough In Fig 2 VRCTL8WS RED...

Страница 5: ...5mm 5 3 4 146mm 5 3 4 146mm 1 3 8 35mm 1 3 8 35mm 18 1 16 459mm 7 178mm 7 178mm 16 5 16 414mm 1 1 4 32mm 1 1 4 32mm VRCTLR8WS REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDREN S ADA COOLER LEGEND A RECO...

Страница 6: ...s and water inlet Connect black reset button wires from non refrigerated unit to the black wires on the refrigerated unit see step 4 6a For Reversed Two Level Model Installations Secure refrigerated u...

Страница 7: ...Water Cooler The water line and Remote Reset Button Wires will still be connected from the Water Cooler to the Bottle Filler 3 For Two Level Model Installations Loosen but DO NOT remove the Pinned To...

Страница 8: ...back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON REFRIG RST BCNT Res...

Страница 9: ...om below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter...

Страница 10: ...ts Kit Electrical Package 220V Kit Solenoid Valve Replacement 220V Kit Drain Pad Kit Button Assembly Kit Top Cover Replacement Kit Gasket VR BF Tower Basin Kit Reset Switch Kit Micro Switch PART NO EL...

Отзывы: