98982C  (Rev. K - 06/16)

VERIFY CONTROL BOARD  SOFTWARE

1) To verify the software program of the control board the

unit will need to be shut down and restarted. The chiller

(if present) does not need to be shut down and restarted.

2) The units lower panel must be open to access the power

cord and wall outlet.

3) Shut down the unit by unplugging the power cord from the

wall outlet.

4)  Restart the unit by plugging the power cord back into the

wall outlet.

5) Upon start up the bottle count display will show the

software designation of BF9 or BF11.

6) Reference the BF9 or BF11 instructions for setting the

control board

.

ACCESSING THE PROGRAMMING BUTTON

1)   To access the program button remove the bottom cover of

the water cooler. The Reset Button is located on the left

side of the cooler, mounted on the side panel support.

Replace the bottom cover after programming operations

are completed.  NOTE: There is a Reset Button located

under the top cover on the left hand side of the Bottle fille

also.

RESET THE  FILTER  MONITOR

1) Instructions apply to filtered units onl .

2) Depress the program button for approximately 2 seconds

    until the display changes then release. The display will

    change and scroll through two messages:

       “RST FLTR” – Reset Filter Monitor

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display

    will scroll through the two messages above for

    three cycles and then default back to bottle count and

     be back in run mode.

3) When the display changes to “RST FLTR”, depress

the button again. The display will change to show

 “FLT =”. Depress the button again and the display

will show “FLTR =0”

4) The Green LED should be illuminated indicating that

the visual filter monitor has been reset

SETTING UNIT TYPE

1) Depress the program button for approximately 2 seconds

until the display changes then release. The display will

 change and scroll through two messages:

 “RST FLTR” – Reset Filter Status LED

“SETTINGS” – System Settings Sub Menu

If the program button is not pushed again the display

 will scroll through the two messages above for

three cycles and then default back to bottle count

  and be back in run mode.

2)  When the display changes to “SETTINGS”, depress

the button again. The display will change to show

 “RNG SET“-  Range set for IR sensor.

       “UNIT TYP“ - Type of unit (REFRIG or NON-REFRIG)

      “RST BCNT“ - Reset bottle count

3)  When display shows “UNIT TYP” push program

 button once the display will show current value

       Can be REFRIG or NON-REFRIG

4) Push button once to change value. Once value is

   selected the display will show the new value.

 (Can be REFRIG or NON-REFRIG)

 “REFRIG“ - stands for refrigerated product. In this

setting the flow rate is estimated at 1.0 gallon per minute

 “NON-REFRIG“ - stands for non-refrigerated product.

In this setting the  flow rate is estimate

  at 1.5 gallons per minute.

Both “REFRIG“ and “NON-REFRIG“ simulate

  1 bottle equal to 20 oz.

5)  Allow approximately 4 seconds to pass and the display

 will return to bottle counter and be in run mode.

 RESETTING BOTTLE COUNT

1) Depress the program button for approximately 2 seconds

until the display changes then release. The display will

 change and scroll through two messages:

 “RST FLTR” – Reset Filter Status LED

 “SETTINGS” – System Settings Sub Menu

If the program button is not pushed again the display

 will scroll through the two messages above for

three cycles and then default back to bottle count

 and be back in run mode.

2) When the display changes to “SETTINGS”, depress

the button again. The display will change to show

 “RNG SET“-  Range set for IR sensor.

 “UNIT TYP“ - Type of unit (REFRIG or NON-REFRIG)

 “RST BCNT“ - Reset bottle count

If the button is not pushed again the display will scroll

through the three messages above for three cycles and

 return to run mode.

3)  When display shows “RST BCNT” push program button

 once the display will show current value e.g. “00033183”.

4) Once display shows current value push the program

button once more to reset back to 0. The display will

show BTLCT = 0 for approximately 2 seconds and

then return to run mode showing 00000000 bottles.

5)  To test bottle counter:

REFRIG units: Push and hold Bottle Filler Button for

9.4 seconds to see bottle counter count 00000001,

 (This is based on filling a 20 oz. bottle)

NON-REFRIG units: Push and hold Bottle Filler Button for

6.25 seconds to see bottle counter count 00000001,

(This is based on filling a 20 oz. bottle)

BF9 PROGRAM

SETTING THE CONTROL BOARD

Buy at

| 855-558-9600 | BottleFillingStations.com

Содержание VRC8WS

Страница 1: ...LATION CARE USE MANUAL IMPORTANT THIS IS AN INDOOR OUTDOOR APPLICATION ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON Model VRC8WS Model VRCTL8WS Model VRCTLR8WS Buy at 855 558 9600 Bottl...

Страница 2: ...COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A METALLI...

Страница 3: ...4 X 1 2 6mm X 13mm OBROUND HOLE 5 PL HANGER BRACKET 7 178mm 7 178mm 16 5 16 414mm 1 1 4 32mm 1 1 4 32mm Single Rough In Fig 1 VRC8WS REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDREN S ADA COOLER LEGEN...

Страница 4: ...mm 7 178mm 1 1 4 32mm 1 1 4 32mm 16 5 16 414mm O 5 16 8mm HOLES 3 PL 5 3 4 146mm 5 3 4 146mm 1 3 8 35mm 1 3 8 35mm 18 1 2 470mm 3 1 2 89mm 4 1 2 114mm 6 1 4 159mm Two Level Rough In Fig 2 VRCTL8WS RED...

Страница 5: ...5mm 5 3 4 146mm 5 3 4 146mm 1 3 8 35mm 1 3 8 35mm 18 1 16 459mm 7 178mm 7 178mm 16 5 16 414mm 1 1 4 32mm 1 1 4 32mm VRCTLR8WS REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDREN S ADA COOLER LEGEND A RECO...

Страница 6: ...s and water inlet Connect black reset button wires from non refrigerated unit to the black wires on the refrigerated unit see step 4 6a For Reversed Two Level Model Installations Secure refrigerated u...

Страница 7: ...Water Cooler The water line and Remote Reset Button Wires will still be connected from the Water Cooler to the Bottle Filler 3 For Two Level Model Installations Loosen but DO NOT remove the Pinned To...

Страница 8: ...back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON REFRIG RST BCNT Res...

Страница 9: ...om below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter...

Страница 10: ...ts Kit Electrical Package 220V Kit Solenoid Valve Replacement 220V Kit Drain Pad Kit Button Assembly Kit Top Cover Replacement Kit Gasket VR BF Tower Basin Kit Reset Switch Kit Micro Switch PART NO EL...

Отзывы: