LJNED10_2AQ
PAGE 5
1000002311 (Rev. D - 05/16)
1. Familiarize
yourself with the mounting frame which should already be in place in the wall. If not, refer to the mounting frame installation
instructions on page 2 before proceeding.
2. Determine
location of rough plumbing. At this point, you should decide which style trap you plan to use. For easier installation, we
recommend the use of a swivel trap.
3. Install
the basin (See Figure 10). Hold the basin flush against the wall, positioning the top edge just above the upper edge of the wall
frame. Then slide the basin down slowly until it engages the hanger bracket. Be sure the basin is firmly engaged before releasing it.
4. Finish
securing the basin in place. Align the brackets (item 15) at the bottom of the basin with the bracket on the frame. Fasten the
brackets together using screws and speed nuts (provided, items 8, 28).
5. Install
tailpiece assembly. Slide the slip nut and gasket from the trap onto the tailpiece. Insert the tailpiece assembly into the trap and
align its other end with the drain hole in the basin. Place rubber gasket between the tailpiece assembly and the basin, then screw in the
drain plug from above. Tighten the drain plug. Tighten slip nut and swivel joint. Snap the strainer plate into the drain plug.
6. Install
a service stop (not provided) on the supply water inlet line. Turn on supply water and flush thoroughly.
7. Install
remote chiller. Verify that filter has been installed inside chiller. Slide chiller onto shelf and center it within the shelf guides.
NOTE:
Building construction must allow for adequate air flow on both sides, top, and back of chiller. See chiller instructions for additional
information.
8. Make
connection between chiller inlet and building supply line (3/8” O.D. copper tube).
DO NOT SOLDER TUBES
INSERTED INTO THE UNIONS AS DAMAGE TO THE O-RINGS MAY RESULT.
(See Figure ).
9. Make
connections between remote chiller and fountain. Outlet port is marked on the chiller (3/8” O.D. copper tube).
Install a 3/8” x 1/4” x 1/4” T-joint (provided, item 3) on the marked chiller outlet port. Insert 1/4” Poly in the T-joint and run
line to regulator.
10.
Insert 1/4” elbow stem (item 31) into other end of T-joint (item 3). Insert 1/4” elbow stem (item 31) into cup filler (see
figure 13. Run 1/4” poly tubing (provided, 30”) between the two elbow stems. Turn on water supply, check for leaks, and
purge air from lines.
DO NOT SOLDER TUBES INSERTED INTO THE UNIONS AS DAMAGE TO THE O-RINGS MAY
RESULT.
(See Figure 11).
11. These
products are designed to operate on 20-105 PSIG (0.14-0.72 MPa) supply line pressure. If inlet pressure is
above 105 PSIG (0.72 MPa), a pressure regulator must be installed in the supply line. Any damage caused by reason of
connecting these products to supply line pressures lower than 20 PSIG (0.14 MPa) or higher than 105 PSIG (0.72 MPa)
is not covered by warranty.
12. Make
electrical connections to the chiller. See chiller instructions.
13. Check
stream height from bubbler. Stream height is factory set at 35 PSI. If supply pressure varies greatly from
this, remove items 14 & 16 and adjust screw on regulator (item 27) (See Figure 16). Clockwise adjustment will raise
stream height and counter-clockwise adjustment will lower stream height. For best adjustment, stream should hit basin
approximately 6-1/2” from bubbler.
14. Install
pushbutton to grill. See Figure 16. Hold grill and engage angle on top edge of grill with lower edge of basin. Swing
bottom of grill into place against the wall and secure grill with mounting screws (provided).
FOUNTAIN INSTALLATION INSTRUCTIONS
BASIN INSTALLATION
FIG. 10