background image

EZOTL8WS*1A   LZOTL8WS*1A

Page 12

1000005927 (Rev. C - 08/21)

7/16” BOLT  HOLES FOR  

FASTENING UNIT TO WALL

UNIT CENTER LINE

TOP COVER

MOUNTING 

SCREWS

Fig. 8

Fig. 9

31

Bottle Filler Installation Instructions

1)  

Remove two (2) mounting screws

 with 5/32” Allen wrench holding top cover to Bottle Filler (See Fig. 9). Remove top cover. Note do not discard mounting screws, they will be   

needed to reinstall top cover. 

2)  

Remove wall mounting plate

 from Bottle Filler. Place wall plate against wall on top of basin. Center the wall plate side to side with the basin. Mark the six (6) mounting holes 

with a pencil (See Fig. 2, 3, 4 or 5). 

3)  

Remove wall mounting plate

 from wall. 

NOTE

: Mounting plate 

MUST

 be supported securely. Add fixture support carrier if wall will not provide adequate support. 

4)  

Install wall mounting plate 

to wall using six (6) 7/16” obround mounting holes (mounting bolts not included) (See Fig. 8). Use appropriate fasteners for your wall type. 

5)  

Lay Bottle Filler on water cooler basin

 and cut insulation from tube even with bottom of gasket, remove this insulation from the 3/8” tube, but do not discard. 

Feed the power cord and waterline through the hole on top of water cooler. 

NOTE:

 To prevent scratching the basin place a towel or soft cloth over the entire basin when 

 

working above it. 

6)  

Install gasket 

on bottom of bottle filler tower with gasket support bracket & (2) screws (See Fig 11). 

7)  

Feed power cord

 & 3/8” water line through hole in tower/basin gasket (See Fig 10).

8)  

With the power cord,

 wire(s), and waterline through hole on top of water cooler place Bottle Filler on the three (3) angled tabs protruding from the wall mounting plate installed 

on wall. Make sure round boss in gasket fits in hole of basin. 

9)  

Once Bottle Filler is installed

 on wall plate tabs, make sure the water line, wire(s) and power cord are installed properly. Inspect for leaks and fix all leaks before 

 

continuing. Push the top of Bottle Filler toward wall and line up top cover two (2) holes. 

10) 

Reinstall Top Cover 

on Bottle Filler (See Fig. 9) with two mounting screws from step 1 above. Caution, do not over tighten screws. 

11) 

Install remaining tube insulation

 to the water line from bottle filler, connect Bottle Filler waterline inside of the water cooler by connecting the 3/8” water line to the tee. 

12) 

Install filter cartridge, 

remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter clockwise.

13) 

Turn water supply on 

and inspect for leaks. Fix all leaks before continuing. 

14) 

Once unit has been inspected 

for leaks and any leaks found corrected, plug Bottle Filler and unit into wall for correct electrical cord routing 

 

and connections (See Fig 28), be sure to reinstall fuse to the circuit or switch the circuit breaker back to the “ON” position. 

15) 

Once power is applied to Bottle Filler,

 the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter. 

16) 

Verify proper dispensing 

by placing cup, hand, or any opaque object in front of sensor area and verify water dispenses. 

NOTE:

 The first initial dispenses might have air in 

line 

      which may cause a sputter. This will be eliminated once all air is purged from the line. 

17) 

Once unit tests out,

 install Lower Panel back on water cooler(s). Unit is now ready for use.

Fig. 11

Fig. 10

BRACKET & SCREWS

Содержание Flexi-Guard EZOO Series

Страница 1: ...hange may be required See desired rough in to help determine if the basin change is necessary Refrigerated unit must be installed on right hand side INSTALLATION USE MANUAL Manual de instalación y uso Manuel d installation et utilisation EZOO LZOO Stations de remplissage et refroidisseurs de bouteilles de la série polyvalente commandés par capteur EZOO LZOO Estaciones y enfriadores de botellas ver...

Страница 2: ...nstale una unión entre la válvula de la fuente y el enfriador NO DEBE SOLDAR LOS TUBOS INTRODUCIDOS AL FILTRO YA QUE PU EDEN RESULTAR EN DAÑOS A LOS AROS TÓRICOS Nota No se suministra el filtro en unidades con un filtro de agua Simplemente hay que introducir una línea de agua de 3 8 al accesorio en el cabezal del filtro hasta que llegue a un tope positivo aprox 3 4 Nota Si necesario podrá obtener ...

Страница 3: ...te la lista de piezas para el número de pieza cor recta para el regulador 17 AGUA SALE CONTINUAMENTE DEL BURBU JEADOR BOQUILLA Cuando esto ocurre al final del ciclo del compresor dé una cuarta de vuelta hacia la izquierda al control de enfriamiento hacia una tem peratura más alta También para enfriadores con barras de empuje consulte PROCEDIMIENTO DE AJUSTE del Manual del Enfriador Mecanismo de la...

Страница 4: ...ella Sur la photo est une unité seulement sans remplissage de la bouteille Uses HFC 134A refrigerant Usa refrigerante HFC 134A Utilise du fluide frigorigéne HFC 134A Note Danger Electric shock hazard Disconnect power before servicing unit Nota peligro Peligro de descarga eléctrica Desconecte antes de reparar la unidad Remarque Danger Risque d électrocution Débrancher avant de réparer l appareil 33...

Страница 5: ... 1 1 2 O D DRAIN STUB 2 IN OUT FROM WALL UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA DE 1 1 2 DE DIÁMETRO El TALONARIO 2 FUERA DE PARED EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D E 1 1 2 DE SORTIE D EAU STUB 2 HORS DU MUR C 1 1 2 TRAP NOT FURNISHED PURGADOR DE 1 1 2 NO PROPORCIONADO SIPHON 1 1 2 NON FOURNI NOTE IT IS HIGHLY RECOMMENDED THAT THE CIRCUIT BE DEDICATED AND THE LOAD PROTECTI...

Страница 6: ...N OUT FROM WALL UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA DE 1 1 2 DE DIÁMETRO El TALONARIO 2 FUERA DE PARED EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D E 1 1 2 DE SORTIE D EAU STUB 2 HORS DU MUR C 1 1 2 TRAP NOT FURNISHED PURGADOR DE 1 1 2 NO PROPORCIONADO SIPHON 1 1 2 NON FOURNI NOTE IT IS HIGHLY RECOMMENDED THAT THE CIRCUIT BE DEDICATED AND THE LOAD PROTECTION BE SIZED FOR 20 AMPS L...

Страница 7: ... 2 O D DRAIN STUB 2 IN OUT FROM WALL UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA DE 1 1 2 DE DIÁMETRO El TALONARIO 2 FUERA DE PARED EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D E 1 1 2 DE SORTIE D EAU STUB 2 HORS DU MUR C 1 1 2 TRAP NOT FURNISHED PURGADOR DE 1 1 2 NO PROPORCIONADO SIPHON 1 1 2 NON FOURNI NOTE IT IS HIGHLY RECOMMENDED THAT THE CIRCUIT BE DEDICATED AND THE LOAD PROTECTION B...

Страница 8: ...LL UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA DE 1 1 2 DE DIÁMETRO El TALONARIO 2 FUERA DE PARED EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D E 1 1 2 DE SORTIE D EAU STUB 2 HORS DU MUR C 1 1 2 TRAP NOT FURNISHED PURGADOR DE 1 1 2 NO PROPORCIONADO SIPHON 1 1 2 NON FOURNI NOTE IT IS HIGHLY RECOMMENDED THAT THE CIRCUIT BE DEDICATED AND THE LOAD PROTECTION BE SIZED FOR 20 AMPS LEGEND LEYENDA...

Страница 9: ... INSTALLATION OF COOLER 3 Hang the cooler on the hanger bracket Be certain the hanger bracket is engaged properly in the slots on the cooler back as shown in Figures 2 3 4 or 5 4 Remove the four 4 screws holding the lower front panel at the bottom of cooler Remove the front panel by pulling straight down and set aside 5 Connect water inlet line See Note 4 of General Instructions 6 Install trap Rem...

Страница 10: ...nect the power supply The underside of the bubbler can be reached through the access panel on the underside of the upper shroud Remove the access panel by remov ing the retaining screw To remove the bubbler loosen locknut from the underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick Connect Fittings section in the General Instructions After servi...

Страница 11: ...w trim piece to wrapper with 2 screws provided 3 Re install wrapper with 4 screws 4 Dispose of unused cover plate Right Hand Wrapper Low Side 1 Remove existing wrapper by removing the 4 screws from bottom 2 Clip cover plate sliding until plate sits flush with the wall 3 Re install wrapper with 4 screws 4 Dispose of unused trim piece Left Hand Wrapper High Side 1 Remove existing wrapper by removing...

Страница 12: ... on the three 3 angled tabs protruding from the wall mounting plate installed on wall Make sure round boss in gasket fits in hole of basin 9 Once Bottle Filler is installed on wall plate tabs make sure the water line wire s and power cord are installed properly Inspect for leaks and fix all leaks before continuing Push the top of Bottle Filler toward wall and line up top cover two 2 holes 10 Reins...

Страница 13: ...pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count 3 W...

Страница 14: ... power cord Disconnect the water line at the solenoid valve Reference Fig 25 Pg 19 for the operation of the quick connect fittings Using a T20 6 point star bit loosen the shroud screws Both sides both coolers ONLY move the filler panel and j clip to the refrigerated right side if right side will be mounted high Refrigerated Cooler side Carefully lift and tip the shroud basin assembly off of the co...

Страница 15: ...des both coolers being careful not to overtighten SEE PAGES 16 17 FOR PLUMBING DIAGRAMS Precautions need to be taken when replacing the Basin shroud assembly 1 Make sure all wires are inside frames so as not to become pinched 2 Water line coming from bottle fillter drain must be pulled down as not to interfere with the fan operation The fan blade needs to spin freely INSTALL WRAPPERS TRIM STRIPS P...

Страница 16: ...EZOTL8WS 1A LZOTL8WS 1A Page 16 1000005927 Rev C 08 21 PLUMBING DIAGRAMS VERSATILE BI LEVEL Bottle Filler Drain Bottle Filler Drain Bottle Filler Drain Bottle Filler Drain Fig 20 ...

Страница 17: ...nit L H Non Refrig unit Bubbler Evaporator 3 8 Water Inlet Tee 3 8 Water Line from Bottle Filling Unit Filter Assembly 1 4 Union Solenoid Valve Solenoid Valve PLUMBING DIAGRAMS FOR EZ BI LEVEL COOLERS R H Refrig unit L H Non Refrig unit Evaporator 3 8 Water Inlet 3 8 Water Line from Bottle Filling Unit regulator Bubbler regulator Bubbler Bubbler Tee Solenoid Valve Solenoid Valve regulator regulato...

Страница 18: ...ado REMARQUE Lors de L installation du barboteur de remplacement ou du socle serez la vis afin de maintenir les elemants en place Ne Pas Serrer Trop Fortement Basin Estanque Bassin 12 Fig 22 Fig 23 Fig 24 115V Non Refrigerated Wiring Diagram Diagrama de cableado no refrigerados de 115 voltios schéma de câblage non réfrigéré de 115 volts 115V Refrigerated Wiring Diagram Diagrama de cableado refrige...

Страница 19: ...tg Bkt John Guest Ftgs Screws 1 2 51300C 0000000895 Ensamblado del Filtro 3000 Galón Conjunto del Filtro y Soporte Incluye Filtro Soporte John Guest Guarniciones Tornillos de Montaje de Cabeza DESCRIPTION PART NO Ens filtre 3000 Gallon Assemblêe Filtre et Support Inclut Filtre Montage Support John Guest Vis à Têtê DESCRIPTION FILTER PARTS LIST LISTA DE PIEZAS DEL FILTRO LISTE DES PIÈCES DU FILTRE ...

Страница 20: ...TL8WS 1A Page 20 1000005927 Rev C 08 21 Standard Rough In Primary Outlet Location Standard Rough In Alternate Outlet Location Reverse Rough In Primary Outlet Location Reverse Rough In Alternate Outlet Location Fig 28 ...

Страница 21: ...24 25 26 27 28 29 30 31 32 33 34 NS NS NS NS Soporte Colgante Estanque Acero Inoxidable Estanque Acero Inoxidable BF Compresor Paquete de Servicio 115V Tubo Poli Corte a la longitud Cubierta Superior Secador Kit Reemplazo de Drenaje EZTL8 Soporte Tubo Guarnición de Tubo Abrazadera Kit Reemplazo de Drenaje EZTLD Soporte Tubo Guarnición de Tubo Abrazadera En Line Strainer Kit Montaje del Regulador V...