Elkay ezH2O LBWD06BKK Скачать руководство пользователя страница 5

(630) 574-8484 

Elkay Manufacturing Company 

Installation Manual (1000005232 Rev. D - 08/21) 

 

In-Wall Filtered Water Dispenser

2. Safety

 

 

THINK

SAFETY!

Think Safety

Before performing any work, read and 

understand the safety instructions in 

this manual. 

2.1  General

The Elkay Manufacturing Company (Elkay) cannot 

anticipate every possible circumstance that might involve 

a potential hazard during the installation or maintenance 

of this product. The warnings and instructions in this 

Installation Manual are, therefore, not all-inclusive. If a 

tool, installation procedure, or work method that is not 

specifically recommended by Elkay is used, you must be 

satisfied that it is safe for yourself and others. You should 

also make sure that the product will not be damaged by 

the methods you choose.  

Most work-related accidents are caused by failure to 

observe basic safety rules or precautions.  An accident 

can often be avoided by recognizing potentially 

hazardous situations before an accident occurs. As you 

install and maintain this product, you must be alert to 

potential hazards. You should also have the necessary 

training, skills, and tools to perform any installation or 

maintenance procedure.

2.2  Safety Alert Symbol

This is the safety alert symbol. It is used to 

alert you to potential personal injury hazards. 

Obey all safety messages that follow this 

symbol to avoid possible injury or death.

This manual contains WARNINGS, CAUTIONS, 

NOTICES, SAFETY INSTRUCTIONS, and NOTES which 

must be followed to prevent the possibility of improper 

service, damage to the equipment, personal injury, or 

death. The following keywords call the reader’s attention 

to potential hazards.

Hazards are identified by the “Safety Alert Symbol” 

and followed by a signal word such as “WARNING” or 

“CAUTION”.

2.3  Personal Safety

DANGER

•  Please read these instructions completely 

before starting the installation or performing any 

service. Failure to follow the instructions and 

safety precautions in this manual can result in 

serious injury or death.

•  After installation, keep these instructions in a 

safe location for future reference.

•  Electric supply must be identical in voltage, 

cycle, and phase to that specified on nameplate.

•  Electrical supply must have Ground Fault Circuit 

Interrupter (GFCI) protection.

•  A means for disconnecting electrical supply to 

the unit must be incorporated in the fixed wiring 

in accordance with wiring rules. This is to allow 

electrical disconnection of the unit from electrical 

supply after installation.

WARNING

These warnings indicate a potentially hazardous 

situation which, if not avoided, could result in serious 

injury or death. Follow all instructions related to the 

installation and/or maintenance of this product (unit).

For use with clean, clear potable drinking water only. 

Do not use with water that is microbiologically unsafe 

or of unknown quality without adequate disinfection 

before the system.

Installation and connection to water and electrical 

mains must be in compliance with local and national 

laws.

All Installation and Service work must be performed 

by an authorized service personnel.

Personal Protection

   

Be sure to use all personal protective 

equipment, such as sturdy safety glasses, 

work shoes, hearing protection, and cut resistant 

gloves, whenever necessary, to ensure your own 

safety.  

To avoid eye injury, always wear protective 

glasses with side shields when using 

power tools. Also, make sure no one else 

can be injured by flying particles when using 

power tools. 

Always wear ear protection, such as 

earmuffs or earplugs, when using power 

tools.

 Wear protective cut resistant gloves 

during installation to protect against 

sharp edges from sheet metal 

components.

Power Tool Hazard

   

To prevent personal injury or possible death, 

always follow the electrical safety 

recommendations of the power tool’s manufacturer. 

Содержание ezH2O LBWD06BKK

Страница 1: ...anufacturing Company Installation Manual 1000005232 Rev D 08 21 In Wall Filtered Water Dispenser Installation Manual ezH2O Liv Residential Built in Filtered Refrigerated Water Dispenser with Remote Chiller LBWD06BKK LBWD06WHK ...

Страница 2: ...Elkay Manufacturing Company 2 630 574 8484 In Wall Filtered Water Dispenser Installation Manual 1000005232 Rev D 08 21 ...

Страница 3: ...lectrical codes WARNING Carefully read understand and follow all the instructions in this manual before using the product Improper installation use or maintenance of this product could cause a dangerous situation resulting in personal injury or even death Do not operate power tools unless you read and understand the instructions and warnings in this and all other applicable manuals Proper use of t...

Страница 4: ...ce complies with part 15 of the FCC Rules Operation is subject to the following two 2 conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not approved by the manufacturer could void the user s authority to operate the equipment This device complies with...

Страница 5: ...ese instructions completely before starting the installation or performing any service Failure to follow the instructions and safety precautions in this manual can result in serious injury or death After installation keep these instructions in a safe location for future reference Electric supply must be identical in voltage cycle and phase to that specified on nameplate Electrical supply must have...

Страница 6: ... power has been disconnected Contact with live electricity can cause serious bodily injury and in some cases death CAUTION These cautions indicate a potentially hazardous situation which if not avoided may result in minor or moderate injury Follow all instructions related to installation and or maintenance of this product This appliance can be used by children aged from 8 years and above and perso...

Страница 7: ... drives Fasteners for wall type NOTICE The installation of this product requires electrical and plumbing connections that use specific skills and knowledge If you are unsure or not qualified to make these connections consult a qualified plumber electrician or installer for this installation Professional installation is recommended 1 This water dispenser is designed for indoor use only and should n...

Страница 8: ...o the household water source and waste drain 3 32 Allen Wrench Remove the front covers 1 4 Socket Wrench To release fix grounding screw 4 2 Parts Required not Included Description Qty 8 Flathead Screws 1 1 4 long 8 Electrical 12 2 with ground electrical wire depending on local building codes the installation could require rigid conduit armored cable or plastic sheath NM B cable Electrical wire nut...

Страница 9: ...ithin the wall under the water dispenser all the plumbing joints must be glued The glue must be appropriate for the PVC pipe utilized If the p trap uses threaded components they must be easily accessible Note Item 2 According to most electrical codes the electrical box cannot be sealed inside a wall cavity with no access If the electrical connection is placed under the unit a user supplied removab...

Страница 10: ...ectrical wiring through a wiring clamp into the gang box NOTICE Do not use a cord with a three prong plug to power this unit b Tighten the wiring clamp to prevent the wire from being pulled out of the gang box c Connect black wire to supplied voltage line black wire and the white wire to neutral d Use installer provided wire nuts to insulate the connections e If required by code a green grounding ...

Страница 11: ...nsulated water line to either a remote chiller if used or the 1 4 water line on the bottle filler Use a union connection fitting to connect the water line to the bottle filler The type of 1 4 tubing copper or plastic should meet all local regulations and building codes This line should be insulated to prevent condensation NOTICE Do not disconnect the 1 4 tubing from the water valve at the top of t...

Страница 12: ...is after the chiller the unit will dispense ambient water for 1 2 cycles before receiving chilled water Water Filter Water Chiller Water Dispenser Note The remote chiller can take from 24 to 48 hours to provide completely chilled water Water lines must be insulated to prevent condensation 4 9 Connecting Catch Basin Drain optional Installing the drain is highly recommended to prevent basin overflow...

Страница 13: ...o make connections 6 Attach one end of the 3 4 flexible drain hose to the 3 4 barbed drain adapter connection using the supplied hose clamp The supplied flexible drain is 13 long If a longer drain hose is required it must be installer supplied 7 Place the drain basin back into the water dispenser and reinstall the two screws 8 Attach the other end to the p trap drain adapter using a hose clamp The...

Страница 14: ...s of water has been dispensed to prevent overflow and potential flooding so multiple activations will be required to get the required one gallon of water flow through the unit 6 If there are no leaks and the unit is functioning correctly install the water dispenser s glass front cover using the flathead screws and a 3 32 hex wrench 7 Upon initial startup the PLASTIC BOTTLES SAVED indicator panel s...

Страница 15: ...812 1000005394 1000005395 Fitting Hose to Trap KIT Solenoid LED Bezel KIT Harness Wire 18 NFC Remote Filter Connection Alcove KIT Alcove KIT Drain Basin Switch Rocker LIV Box Conduit Lens KIT IR Connector Elbow 1 4 O D X 90 3 000 Gal Filter KIT Filter Head and Bracket Assembly KIT Replacement Glass Black KIT Replacement Glass White KIT Bottle Filler Drain KIT Control Board KIT NFC Reader NS NOT SH...

Страница 16: ...Elkay Manufacturing Company 16 630 574 8484 In Wall Filtered Water Dispenser Installation Manual 1000005232 Rev D 08 21 ALCOVE LEDs Electrical Diagram Filter Head Assembly Fig 5 Fig 4 3 2 11 14 ...

Страница 17: ...d Water pressure must be between 40 and 105 psi Filter is plugged Replace filter Solenoid water valve not opening fully Replace solenoid water valve No water flow No electrical power Restore power to the unit Water shut off valve s closed Open all shut off valves one is located inside the filter box if installed and another may be at the water source Bottle sensor is not operating properly Sensor ...