background image

(630) 574-8484 

11 

Elkay Manufacturing Company 

Installation Manual (1000005232 Rev. D - 08/21) 

 

In-Wall Filtered Water Dispenser

2. 

Securely mount the filter head vertically in the desired 

remote location within 15ft of water dispenser and 

chiller. 

One recommendation is to install the filter head 

by screwing it into a stud on the back side of a wall. 

a.  Remove the short 3/8" copper inlet water tube.

b.  Remove the NFC card.

c.  Remove the four screws that hold the bracket to 

the filter head. 

A

B

c

d.  Screw the bracket to a wall stud, then reassemble 

the filter head, NFC card, and inlet water tube.

Note:

 If desired, you can install the filter into the filter 

head now.

3.  Connect a 3/8" water supply line, copper or plastic, to 

the quarter-turn shutoff valve at the remote location.

4.  Connect a 1/4" supplier installed insulated copper or 

plastic, to the outlet connector of the filter.

5.  Connect the 1/4" insulated water line to either a 

remote chiller (if used) or the 1/4" water line on 

the bottle filler. Use a union connection fitting to 

connect the water line to the bottle filler. The type of 

1/4" tubing, copper or plastic, should meet all local 

regulations and building codes. This line should be 

insulated to prevent condensation.

NOTICE

Do not disconnect the 1/4" 

tubing from the water valve at 

the top of the water dispenser. This connection has 

been factory tested to be leak-free and could result in 

water leaking into the unit if this connection is 

changed.

6. 

Mark the current date on the water filter label.

7. 

Place the filter into filter head with the label facing 

outward. 

8. 

Firmly press the filter into the filter head and turn it 

clockwise. 

Note: 

When a filter requires replacement, a red indicator 

light illuminates on the bottle filler. If the new filter 

is installed and red indicator light is still ON the 

filter has been installed incorrectly. The filter can 

only be installed in one direction (label facing 

outward). If the red indicator light is ON, the filter is 

installed backwards.

Содержание ezH2O LBWD06BKK

Страница 1: ...anufacturing Company Installation Manual 1000005232 Rev D 08 21 In Wall Filtered Water Dispenser Installation Manual ezH2O Liv Residential Built in Filtered Refrigerated Water Dispenser with Remote Chiller LBWD06BKK LBWD06WHK ...

Страница 2: ...Elkay Manufacturing Company 2 630 574 8484 In Wall Filtered Water Dispenser Installation Manual 1000005232 Rev D 08 21 ...

Страница 3: ...lectrical codes WARNING Carefully read understand and follow all the instructions in this manual before using the product Improper installation use or maintenance of this product could cause a dangerous situation resulting in personal injury or even death Do not operate power tools unless you read and understand the instructions and warnings in this and all other applicable manuals Proper use of t...

Страница 4: ...ce complies with part 15 of the FCC Rules Operation is subject to the following two 2 conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not approved by the manufacturer could void the user s authority to operate the equipment This device complies with...

Страница 5: ...ese instructions completely before starting the installation or performing any service Failure to follow the instructions and safety precautions in this manual can result in serious injury or death After installation keep these instructions in a safe location for future reference Electric supply must be identical in voltage cycle and phase to that specified on nameplate Electrical supply must have...

Страница 6: ... power has been disconnected Contact with live electricity can cause serious bodily injury and in some cases death CAUTION These cautions indicate a potentially hazardous situation which if not avoided may result in minor or moderate injury Follow all instructions related to installation and or maintenance of this product This appliance can be used by children aged from 8 years and above and perso...

Страница 7: ... drives Fasteners for wall type NOTICE The installation of this product requires electrical and plumbing connections that use specific skills and knowledge If you are unsure or not qualified to make these connections consult a qualified plumber electrician or installer for this installation Professional installation is recommended 1 This water dispenser is designed for indoor use only and should n...

Страница 8: ...o the household water source and waste drain 3 32 Allen Wrench Remove the front covers 1 4 Socket Wrench To release fix grounding screw 4 2 Parts Required not Included Description Qty 8 Flathead Screws 1 1 4 long 8 Electrical 12 2 with ground electrical wire depending on local building codes the installation could require rigid conduit armored cable or plastic sheath NM B cable Electrical wire nut...

Страница 9: ...ithin the wall under the water dispenser all the plumbing joints must be glued The glue must be appropriate for the PVC pipe utilized If the p trap uses threaded components they must be easily accessible Note Item 2 According to most electrical codes the electrical box cannot be sealed inside a wall cavity with no access If the electrical connection is placed under the unit a user supplied removab...

Страница 10: ...ectrical wiring through a wiring clamp into the gang box NOTICE Do not use a cord with a three prong plug to power this unit b Tighten the wiring clamp to prevent the wire from being pulled out of the gang box c Connect black wire to supplied voltage line black wire and the white wire to neutral d Use installer provided wire nuts to insulate the connections e If required by code a green grounding ...

Страница 11: ...nsulated water line to either a remote chiller if used or the 1 4 water line on the bottle filler Use a union connection fitting to connect the water line to the bottle filler The type of 1 4 tubing copper or plastic should meet all local regulations and building codes This line should be insulated to prevent condensation NOTICE Do not disconnect the 1 4 tubing from the water valve at the top of t...

Страница 12: ...is after the chiller the unit will dispense ambient water for 1 2 cycles before receiving chilled water Water Filter Water Chiller Water Dispenser Note The remote chiller can take from 24 to 48 hours to provide completely chilled water Water lines must be insulated to prevent condensation 4 9 Connecting Catch Basin Drain optional Installing the drain is highly recommended to prevent basin overflow...

Страница 13: ...o make connections 6 Attach one end of the 3 4 flexible drain hose to the 3 4 barbed drain adapter connection using the supplied hose clamp The supplied flexible drain is 13 long If a longer drain hose is required it must be installer supplied 7 Place the drain basin back into the water dispenser and reinstall the two screws 8 Attach the other end to the p trap drain adapter using a hose clamp The...

Страница 14: ...s of water has been dispensed to prevent overflow and potential flooding so multiple activations will be required to get the required one gallon of water flow through the unit 6 If there are no leaks and the unit is functioning correctly install the water dispenser s glass front cover using the flathead screws and a 3 32 hex wrench 7 Upon initial startup the PLASTIC BOTTLES SAVED indicator panel s...

Страница 15: ...812 1000005394 1000005395 Fitting Hose to Trap KIT Solenoid LED Bezel KIT Harness Wire 18 NFC Remote Filter Connection Alcove KIT Alcove KIT Drain Basin Switch Rocker LIV Box Conduit Lens KIT IR Connector Elbow 1 4 O D X 90 3 000 Gal Filter KIT Filter Head and Bracket Assembly KIT Replacement Glass Black KIT Replacement Glass White KIT Bottle Filler Drain KIT Control Board KIT NFC Reader NS NOT SH...

Страница 16: ...Elkay Manufacturing Company 16 630 574 8484 In Wall Filtered Water Dispenser Installation Manual 1000005232 Rev D 08 21 ALCOVE LEDs Electrical Diagram Filter Head Assembly Fig 5 Fig 4 3 2 11 14 ...

Страница 17: ...d Water pressure must be between 40 and 105 psi Filter is plugged Replace filter Solenoid water valve not opening fully Replace solenoid water valve No water flow No electrical power Restore power to the unit Water shut off valve s closed Open all shut off valves one is located inside the filter box if installed and another may be at the water source Bottle sensor is not operating properly Sensor ...

Страница 18: ...Elkay Manufacturing Company 18 630 574 8484 In Wall Filtered Water Dispenser Installation Manual 1000005232 Rev D 08 21 Notes ...

Страница 19: ... 630 574 8484 19 Elkay Manufacturing Company Installation Manual 1000005232 Rev D 08 21 In Wall Filtered Water Dispenser ...

Отзывы: