Elkay Manufacturing Company
10
(630) 574-8484
In-Wall Filtered Water Dispenser
Installation Manual (1000005232 Rev. D - 08/21)
3. Using a bubble level, straighten the water dispenser
and attach it to the wall studs using four #8 flathead
screws.
4. Locate the electrical gang box, at the lower right-hand
corner of the water dispenser, and remove the cover.
CAUTION
Follow all safety
practices and industry
regulations and standards when connecting any
electrical device. A minimum 15 AMP GFCI Circuit
Breaker is required for safe installation.
5. Connect a 115V, 60Hz power supply to the water
dispenser. Route the wiring through the wall into the
bottom of the electrical gang box.
a. Route the appropriate electrical wiring through a
wiring clamp into the gang box.
NOTICE
Do not use a cord with a
three-prong plug to power
this unit.
b. Tighten the wiring clamp to prevent the wire from
being pulled out of the gang box.
c. Connect black wire to supplied voltage line (black)
wire and the white wire to neutral.
d. Use installer provided wire nuts to insulate the
connections.
e. If required by code a green grounding screw can
be used to connect a grounding wire inside the
gang box.
f. Reinstall the gang box cover.
4.7 Installing the Remote Filter
The filter is installed remotely, up to 15 feet away from
the water dispenser and in conjunction with a remote
chiller. For chiller installation, please first review section
4.8 to ensure proper preparation is taken.
Note:
The filter should be installed before the remote
chiller for proper water filtration and chilling.
1.
Remove the filter head from the filter box.