Elkay ezH2O LBWD06BKK Скачать руководство пользователя страница 14

Elkay Manufacturing Company 

14 

(630) 574-8484 

In-Wall Filtered Water Dispenser 

 

Installation Manual (1000005232 Rev. D - 08/21)

5. Startup

1.  Open the shutoff valve(s) for the water supply. Check 

for any water leaks.

2.  Place the ON/OFF switch in the upper left-hand corner 

of the water dispenser opening in the OFF position. 

Turn the power to the unit ON (typically a circuit 

breaker).

3.  Remove the scratch-resistant protective layer that is 

covering the glass face, and the back wall of the water 

dispenser.

Note:

 Not removing the back wall covering layer will 

activate the IR sensor when the unit is turned ON.

4.  Move the power switch to the ON position and make 

sure the LED lights are lit.

5.  Place a container under the water dispenser spout 

to activate the fill sensor and dispense at least one 

gallon of water to bleed off any trapped air from the 

supply lines and filter as well as flush any fine carbon 

particles from the filter.

Note: 

The water dispenser is set to automatically shut 

off after 16 ounces or 12 seconds of water has been 

dispensed to prevent overflow and potential flooding so 

multiple activations will be required to get the required 

one gallon of water flow through the unit.

6.  If there are no leaks and the unit is functioning 

correctly, install the water dispenser's glass front cover 

using the flathead screws and a 3/32" hex wrench.

7.  Upon initial startup, the PLASTIC BOTTLES SAVED 

indicator panel should show several bottles have been 

saved due to the water used to initially start up the 

unit.

8.  The left-most FILTER LIFE indicator light should also 

be lit. This light shows the filter is functioning correctly 

and has used less than 65 percent of its capacity.  

 

When the middle blue light illuminates, the filter has 

reached 66 percent of its life and will need to be 

changed soon. When this indicator light comes on, a 

replacement filter should be ordered.

9.  The right-most light will illuminate in red and indicates 

that the filter should be changed.

FILTER LIFE

PLASTIC BOTTLES SAVED

10. Once the installation is complete, the water has been 

turned on, and any trapped air has been bled from 

the system re-check for any water leaks.

11. 

Enjoy fresh filtered water with your new Elkay 

 

ezH2O Liv Water Dispenser.

Содержание ezH2O LBWD06BKK

Страница 1: ...anufacturing Company Installation Manual 1000005232 Rev D 08 21 In Wall Filtered Water Dispenser Installation Manual ezH2O Liv Residential Built in Filtered Refrigerated Water Dispenser with Remote Chiller LBWD06BKK LBWD06WHK ...

Страница 2: ...Elkay Manufacturing Company 2 630 574 8484 In Wall Filtered Water Dispenser Installation Manual 1000005232 Rev D 08 21 ...

Страница 3: ...lectrical codes WARNING Carefully read understand and follow all the instructions in this manual before using the product Improper installation use or maintenance of this product could cause a dangerous situation resulting in personal injury or even death Do not operate power tools unless you read and understand the instructions and warnings in this and all other applicable manuals Proper use of t...

Страница 4: ...ce complies with part 15 of the FCC Rules Operation is subject to the following two 2 conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not approved by the manufacturer could void the user s authority to operate the equipment This device complies with...

Страница 5: ...ese instructions completely before starting the installation or performing any service Failure to follow the instructions and safety precautions in this manual can result in serious injury or death After installation keep these instructions in a safe location for future reference Electric supply must be identical in voltage cycle and phase to that specified on nameplate Electrical supply must have...

Страница 6: ... power has been disconnected Contact with live electricity can cause serious bodily injury and in some cases death CAUTION These cautions indicate a potentially hazardous situation which if not avoided may result in minor or moderate injury Follow all instructions related to installation and or maintenance of this product This appliance can be used by children aged from 8 years and above and perso...

Страница 7: ... drives Fasteners for wall type NOTICE The installation of this product requires electrical and plumbing connections that use specific skills and knowledge If you are unsure or not qualified to make these connections consult a qualified plumber electrician or installer for this installation Professional installation is recommended 1 This water dispenser is designed for indoor use only and should n...

Страница 8: ...o the household water source and waste drain 3 32 Allen Wrench Remove the front covers 1 4 Socket Wrench To release fix grounding screw 4 2 Parts Required not Included Description Qty 8 Flathead Screws 1 1 4 long 8 Electrical 12 2 with ground electrical wire depending on local building codes the installation could require rigid conduit armored cable or plastic sheath NM B cable Electrical wire nut...

Страница 9: ...ithin the wall under the water dispenser all the plumbing joints must be glued The glue must be appropriate for the PVC pipe utilized If the p trap uses threaded components they must be easily accessible Note Item 2 According to most electrical codes the electrical box cannot be sealed inside a wall cavity with no access If the electrical connection is placed under the unit a user supplied removab...

Страница 10: ...ectrical wiring through a wiring clamp into the gang box NOTICE Do not use a cord with a three prong plug to power this unit b Tighten the wiring clamp to prevent the wire from being pulled out of the gang box c Connect black wire to supplied voltage line black wire and the white wire to neutral d Use installer provided wire nuts to insulate the connections e If required by code a green grounding ...

Страница 11: ...nsulated water line to either a remote chiller if used or the 1 4 water line on the bottle filler Use a union connection fitting to connect the water line to the bottle filler The type of 1 4 tubing copper or plastic should meet all local regulations and building codes This line should be insulated to prevent condensation NOTICE Do not disconnect the 1 4 tubing from the water valve at the top of t...

Страница 12: ...is after the chiller the unit will dispense ambient water for 1 2 cycles before receiving chilled water Water Filter Water Chiller Water Dispenser Note The remote chiller can take from 24 to 48 hours to provide completely chilled water Water lines must be insulated to prevent condensation 4 9 Connecting Catch Basin Drain optional Installing the drain is highly recommended to prevent basin overflow...

Страница 13: ...o make connections 6 Attach one end of the 3 4 flexible drain hose to the 3 4 barbed drain adapter connection using the supplied hose clamp The supplied flexible drain is 13 long If a longer drain hose is required it must be installer supplied 7 Place the drain basin back into the water dispenser and reinstall the two screws 8 Attach the other end to the p trap drain adapter using a hose clamp The...

Страница 14: ...s of water has been dispensed to prevent overflow and potential flooding so multiple activations will be required to get the required one gallon of water flow through the unit 6 If there are no leaks and the unit is functioning correctly install the water dispenser s glass front cover using the flathead screws and a 3 32 hex wrench 7 Upon initial startup the PLASTIC BOTTLES SAVED indicator panel s...

Страница 15: ...812 1000005394 1000005395 Fitting Hose to Trap KIT Solenoid LED Bezel KIT Harness Wire 18 NFC Remote Filter Connection Alcove KIT Alcove KIT Drain Basin Switch Rocker LIV Box Conduit Lens KIT IR Connector Elbow 1 4 O D X 90 3 000 Gal Filter KIT Filter Head and Bracket Assembly KIT Replacement Glass Black KIT Replacement Glass White KIT Bottle Filler Drain KIT Control Board KIT NFC Reader NS NOT SH...

Страница 16: ...Elkay Manufacturing Company 16 630 574 8484 In Wall Filtered Water Dispenser Installation Manual 1000005232 Rev D 08 21 ALCOVE LEDs Electrical Diagram Filter Head Assembly Fig 5 Fig 4 3 2 11 14 ...

Страница 17: ...d Water pressure must be between 40 and 105 psi Filter is plugged Replace filter Solenoid water valve not opening fully Replace solenoid water valve No water flow No electrical power Restore power to the unit Water shut off valve s closed Open all shut off valves one is located inside the filter box if installed and another may be at the water source Bottle sensor is not operating properly Sensor ...

Страница 18: ...Elkay Manufacturing Company 18 630 574 8484 In Wall Filtered Water Dispenser Installation Manual 1000005232 Rev D 08 21 Notes ...

Страница 19: ... 630 574 8484 19 Elkay Manufacturing Company Installation Manual 1000005232 Rev D 08 21 In Wall Filtered Water Dispenser ...

Отзывы: