INSTALLATION INSTRUCTIONS

ALCOVE

DRAIN TRAY

TOP COVER

FRONT VIEW

REAR VIEW

BACK PANEL

OUTER 

WRAPPER

Pre-Installation (reference Rough-In, Fig. 1 and Fig. 3)

1.

  Ensure Wall is structurally sound

 to bear the loads imparted by the EMASM Bottle Filler

     (On-Wall Bottle Filler). If necessary, install a Wall Support Carrier (not supplied). 
2.  

Ensure Water Supply Line and Drain Line are sized

 and located as specified the Rough-in diagram. 

3.

  Attach Service Stop Valve (not supplied) to Water Supply line

 orienting the 3/8"O.D. female compression

  outlet horizontally to the left. Purge water line and test for leakage. Correct any leakage. 
4.  

Ensure package contains the following components: 

Wall Mounting (reference Rough-In, Fig. 1 and Fig. 3)

1.  

Remove Top Cover from Bottle Filler

 by removing two (2) screws from top of unit. Use a 5/32" hex wrench (not

  supplied).   
2. 

 Remove Bottom Cover from Bottle Filler 

by removing two (2) screws from bottom of unit. Use a 5/32" hex

  wrench (not supplied).   
3.  

With the Top and Bottom Covers removed,

 the Back panel is now free to be removed from Bottle Filler.

4. 

 Fasten Back Panel to structurally secure wall 

through five 7/16" obround holes with fasteners appropriate for 

  wall type. Locate Back Panel as specified in Rough-In. If necessary, attach to Wall Support Carrier (not supplied).

5.  

Ensure Back Panel is not obstructed

 by the roughed-in Water and Drain Lines. If Back Panel is prevented from

  seating properly, reposition Water and/or Drain Lines slightly until the Bottom Cover fits easily.

6. 

 Before hanging the On-Wall Bottle Filler,

 ensure the Insulated Waterline is routed inside of the Wrapper If 

  outside the Wrapper, reposition to inside or else the unit cannot be installed properly.
7. 

 Hang the Bottle Filler onto the Back Panel,

 aligning two tabs into the top of the Back Panel.

8.  

Secure Bottle Filler to Back Panel 

by replacing Top Cover on top of unit and fastening with two (2) supplied

 screws.

9.  

Replace the Bottom Cover

 on bottom of the unit and fasten in place with two (2) supplied screws.

EMASM UNIT SHOWN

INSULATED 

WATERLINE

BOTTOM COVER

DISPENSING 

NOZZLE

TOP SCREWS

BOTTOM SCREWS

INSTALLER TO SUPPLY: 

SHUT OFF VALVE

Содержание EMASM

Страница 1: ...nly Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before the system 2 These products are designed to operate on 20 to 105 PSI supply line pressure If inlet pressure is above 105 PSI a pressure regulator must be installed in supply line Any damage caused by reason of connecting this product to supply line pressure lower than 20 PSI or hig...

Страница 2: ...EFORE PULLING IT OUT HELPS TO RELEASE TUBE OPERATION OF QUICK CONNECT FITTINGS SIMPLY PUSH IN TUBE TO ATTACH TUBE IS SECURED IN POSITION PUSH IN COLLET TO RELEASE TUBE PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE A B C FIG 1 ROUGH IN EMASM ADA STAND ALONE MOUNTING LEGEND A RECOMMENDED WATER SUPPLY LOCATION 1 2 IPS MAXIMUM PIPE SIZE SERVICE STOP VALVE NOT FURNISHED B RECOMMENDED WAST...

Страница 3: ...6 152mm MINIMUM CLEARANCE FINISHED FLOOR DRAIN TRAP CUSTOMER SUPPLIED ROUGH IN EMASM ADA ABOVE COOLER MOUNTING FIG 3 LEGEND A RECOMMENDED WATER SUPPLY LOCATION 1 2 IPS MAXIMUM PIPE SIZE SERVICE STOP VALVE NOT FURNISHED B RECOMMENDED WASTE LOCATION WASTE SHOWN IN WALL BUT MAY BE BEHIND WALL OUTLET 1 1 4 O D TRAP NOT FURNISHED C 7 16 X 3 4 OBROUND MOUNTING HOLES FOR FASTENING BACKPLATE TO WALL IMPOR...

Страница 4: ...h not supplied 3 With the Top and Bottom Covers removed the Back panel is now free to be removed from Bottle Filler 4 Fasten Back Panel to structurally secure wall through five 7 16 obround holes with fasteners appropriate for wall type Locate Back Panel as specified in Rough In If necessary attach to Wall Support Carrier not supplied 5 Ensure Back Panel is not obstructed by the roughed in Water a...

Страница 5: ... to unit 2 Connect the 3 8 O D Copper tube from the in line strainer to the 3 8 to the Service Stop Valve 3 Connect the 1 1 4 O D Drain Tray Outlet to the in wall Drain Line using a Slip Joint Drain Union or compression clamp not supplied Tighten all connections water tight 4 Turn water supply on inspect for leaks and correct any leaks before continuing Connect Plumbing Lines PRINTED IN U S A FOR ...

Отзывы: