0000001496 (Rev. F - 08/17)
EMASM*A
Page 2
FINISHED FLOOR
6 1/4"
159mm
4"
102mm
ADA DEPTH
27"
686mm
ADA HEIGHT
38 1/2"
977mm
42 1/8"
1069mm
‰
OF BUTTON
46 1/2"
1182mm
48"
1219mm
ADA HEIGHT
64 3/8"
1635mm
FINISHED FLOOR
7"
178mm
7"
178mm
‰
22"
559mm
40 1/2"
1029mm
45 5/8"
1159mm
44"
1118mm
6"
152mm
MINIMUM
CLEARANCE
3/8"
9.5mm
WATER
INLET
"A"
3"
76mm
1-1/4"
31.7mm
DRAIN
"B"
FILTER USED ONLY
IN LMASMB UNITS
7/16" X 3/4"
11mm X 19mm
OBROUND
MOUNTING
HOLE (6)
"C"
O
3/8"
8mm
(6)
MOUNTING BOLT
DRAIN TRAP
CUSTOMER
SUPPLIED
B
C
A
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A
B
C
FIG. 1
ROUGH-IN
EMASM
ADA STAND-ALONE MOUNTING
LEGEND:
A = RECOMMENDED WATER SUPPLY LOCATION ; 1/2" IPS MAXIMUM PIPE SIZE. SERVICE STOP VALVE NOT FURNISHED.
B = RECOMMENDED WASTE LOCATION. WASTE SHOWN IN WALL BUT MAY BE BEHIND WALL.
OUTLET 1-1/4” O.D. (TRAP NOT FURNISHED)
C =7/16" X 3/4" OBROUND MOUNTING HOLES FOR FASTENING BACKPLATE TO WALL.
FIG. 2
IMPORTANT!
INSTALLATION NOTES:
• Ensure wall is structurally sound to bear the loads imparted by the Surface Mount Bottle Filler.
• Ambient air temperature limits: 10°C - 38°C (50°F - 100.4°F). Climate Class SN-ST.
• Not suitable for installation in areas where water jets could be used.