0000001496 (Rev. F - 08/17)

Page 3

EMASM*A

40 1/2"

1029mm

45 5/8"

1159mm

44"

1118mm

3"

76mm

48"

1219mm

ADA HEIGHT

42 1/8"

1069mm

 OF BUTTON

46 1/2"

1182mm

6 1/4"

159mm

38 1/2"

977mm

64 3/8"

1634mm

7"

178mm

7"

178mm

22"

559mm

     3/8"

 9.5mm

 WATER

INLET

"A"

1-1/4" 

31.7mm

DRAIN

"B"

17 7/8"

454mm

25 7/8"

658mm

7/16" X 3/4"

11mm X 19mm

OBROUND

MOUNTING

HOLE (6)

"C"

ADA HEIGHT

WATER COOLER

4"

102mm

ADA DEPTH

27"

686mm

ADA

HEIGHT

FINISHED FLOOR

FILTER USED ONLY

 IN LMASMB UNITS

O

3/8"

8mm

(6)

MOUNTING

BOLT

6"

152mm

MINIMUM

CLEARANCE

FINISHED FLOOR

DRAIN TRAP

CUSTOMER

SUPPLIED

ROUGH-IN

EMASM

ADA ABOVE COOLER MOUNTING 

FIG. 3

LEGEND:

  A = RECOMMENDED WATER SUPPLY LOCATION ; 1/2" IPS MAXIMUM PIPE SIZE.  SERVICE STOP  VALVE NOT FURNISHED.

  B = RECOMMENDED WASTE LOCATION. WASTE SHOWN IN WALL BUT MAY BE BEHIND WALL. 

 

OUTLET 1-1/4” O.D. (TRAP NOT FURNISHED)

  C =7/16" X 3/4" OBROUND MOUNTING HOLES FOR FASTENING BACKPLATE TO WALL.

IMPORTANT!
INSTALLATION NOTES:
•  Ensure wall is structurally sound to bear the loads imparted by the Surface Mount Bottle Filler.
•  Ambient air temperature limits: 10°C - 38°C (50°F - 100.4°F). Climate Class SN-ST.
•  Not suitable for installation in areas where water jets could be used.

Содержание EMASM

Страница 1: ...nly Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before the system 2 These products are designed to operate on 20 to 105 PSI supply line pressure If inlet pressure is above 105 PSI a pressure regulator must be installed in supply line Any damage caused by reason of connecting this product to supply line pressure lower than 20 PSI or hig...

Страница 2: ...EFORE PULLING IT OUT HELPS TO RELEASE TUBE OPERATION OF QUICK CONNECT FITTINGS SIMPLY PUSH IN TUBE TO ATTACH TUBE IS SECURED IN POSITION PUSH IN COLLET TO RELEASE TUBE PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE A B C FIG 1 ROUGH IN EMASM ADA STAND ALONE MOUNTING LEGEND A RECOMMENDED WATER SUPPLY LOCATION 1 2 IPS MAXIMUM PIPE SIZE SERVICE STOP VALVE NOT FURNISHED B RECOMMENDED WAST...

Страница 3: ...6 152mm MINIMUM CLEARANCE FINISHED FLOOR DRAIN TRAP CUSTOMER SUPPLIED ROUGH IN EMASM ADA ABOVE COOLER MOUNTING FIG 3 LEGEND A RECOMMENDED WATER SUPPLY LOCATION 1 2 IPS MAXIMUM PIPE SIZE SERVICE STOP VALVE NOT FURNISHED B RECOMMENDED WASTE LOCATION WASTE SHOWN IN WALL BUT MAY BE BEHIND WALL OUTLET 1 1 4 O D TRAP NOT FURNISHED C 7 16 X 3 4 OBROUND MOUNTING HOLES FOR FASTENING BACKPLATE TO WALL IMPOR...

Страница 4: ...h not supplied 3 With the Top and Bottom Covers removed the Back panel is now free to be removed from Bottle Filler 4 Fasten Back Panel to structurally secure wall through five 7 16 obround holes with fasteners appropriate for wall type Locate Back Panel as specified in Rough In If necessary attach to Wall Support Carrier not supplied 5 Ensure Back Panel is not obstructed by the roughed in Water a...

Страница 5: ... to unit 2 Connect the 3 8 O D Copper tube from the in line strainer to the 3 8 to the Service Stop Valve 3 Connect the 1 1 4 O D Drain Tray Outlet to the in wall Drain Line using a Slip Joint Drain Union or compression clamp not supplied Tighten all connections water tight 4 Turn water supply on inspect for leaks and correct any leaks before continuing Connect Plumbing Lines PRINTED IN U S A FOR ...

Отзывы: