Controller MO 36
28
phot-cell outside LSI
transmitter 2-6
receiver 1
transmitter 1
receiver 1
24V 0V
1k0
24V 0V
1k0
photo-cell inside LSA
receiver 2-6
24V 0V
1k0
24V 0V
1k0
transmitter 2-6
receiver 1
24V 0V
24V 0V
24V 0V
24V 0V
transmitter 2-6
AMPE
L
BTG
LERN
BT
10.2.1 Photoelectric
barrier connection
Drawing 21
REMARK!
In case the inputs LSA, LSI, or BS are not required, they have to be linked to a jumper.
REMARK!
The direct current supply 24Vdc and 12Vdc can be used for a total of max. 300mA.
The controller provides two inputs for photoelectric barriers for optical protection.
Connect the photoelectric barriers for outside of the gate to the LSA, and for inside of the gate to LSI.
The green LEDs
LSI
and
LSA
show the
status of the photoelectric barriers. When a photoelectric
barrier is interrupted, the corresponding LED lights.