Electrical installation
26
9.4
Programming the gate opener
WARNING!
During the next steps the gate will be moved electrically!
During the programming the safety devices can react differently from normal operation.
Make sure that the range of movement is free of obstacles.
a. Press the button LERN on the controller for approx. 2 seconds. The display shows
p1
.
b. Press the button LERN again. The display now shows
1f
.
c. Chose between gates with one wing (
1f
) or gates with two wings (
2f
) using BT. Confirm
the choice using button LERN. The display shows
ha.
d. During the following step the controller learns the running distance of the gate wings. Press
the button LERN. The controller moves the gate wings into direction OPEN until it reaches the
end stop and then back into direction CLOSED until it reaches the end stop (display shows
p2
).
REMARK!
The gate is now in position CLOSED. If this is not the case then the leads 4 and 5 of the
motor cable of the corresponding gate opener/s have to be interchanged at the terminals.
Then press button
BTG
(display shows
p1
), press button
LERN
3 times (display shows
1f
or
2f
,
ha
and
au
), repeat point d.
e. Push button BT repeatedly until
pp
is displayed. Then confirm using button LERN.