© 14.11.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 21 TERRA 180/182 - 250/252 – 320/322
5. Installation example
Drawing 15
6. Electrical installation
For swing gate openers with radio remote control the controller MO36 should be installed
as close as possible to the gate. The control box should be mounted with the entrance for
wiring at the bottom.
The lead from controller to motor should have at least the cross section stated below. A
smaller gauge will have adverse effect on the motor performance.
Cross section:
5 x 1.5 mm²
up to max.
20 m
Cross
section:
5 x 2.5 mm²
up to max.
40 m
Power supply:
230Vac, 50Hz, single phase
Connection:
By fixed wiring and main switch (on site) or flexible wiring with cable
stress relief device according to European standards.
For the connection motor – controller please use a suitable cable (underground
cable), possibly with a mechanical protection (conduit). The motor cable (enclosed in
shipment) is only suited for the shortest way to the connection box, possibly with a
mechanical protection. To avoid mistakes please use marked (colour) or numbered
leads within the 5-leads cable.