8.1.1. Sequence P1: Learning of the running distance 

 

When sequence P1 has been activated, it has to be selected first between gates with one 
(1F) or with two (2F) wings using button BT. Then confirm the selection with button LERN. 

 

Display 

Effect / Function 

1F 

To operate gates with one wing 

2F 

To operate gates with two wings 

Table 10 

 
Then 

HA 

is displayed. The gate wings now can be operated by dead man’s motion using 

buttons BT or BTG to adjust the internal mechanical end stoppers (when using openers 
like TERRA or ZENIT). BT is used for the main wing and BTG for the pedestrian wing. The 
first direction is always OPEN. 
 

Attention! During learning the safety devices may act different from the 

regular operation. Please ensure that no people are in the danger area during 
learning.

 

 
After adjusting the end stoppers, push the button LERN to continue: The controller tests 
the safety contact strips and the photo-cells. It learns the type of the safety contact strips  
(8.2 k

) and the number of connected photo-cells. Only when this photo-cell testing was 

successful, additional photo-cell tests can be carried out during future operation. 
 

Gates with one wing:  

During learning of the running distance the wing opens first and then closes. 
 

Gates with two wings: 

During learning of the running distance the pedestrian wing opens, the main wing opens, 

the main wing closes and pedestrian wing closes.  
 
In both cases the wings move until they hit the stoppers at the closed position. During the 
learning of the running distance the pressure relief of the electromechanical bolt is not in 
function. The electromechanical bolt is being activated during each wing movement.  
After the learning of the running distance, returning to the main sequence follows 
automatically. 
 

 Remark: 

After adjustment of the end stoppers, the wings should not be in either 

end position but at least 50cm before. The first movement is into direction open. 

Содержание TERRA 180

Страница 1: ...Installation and operating instructions Swing Gate Opener TERRA 180 182 TERRA 250 252 TERRA 320 322...

Страница 2: ...tion plan of the controller MO36 ________________________________________________________22 8 Programming MO36 _________________________________________________________________________25 8 1 Learning...

Страница 3: ...s intended During installation initial operation phase maintenance and testing of the controller the individually relevant regulations for safety and accident prevention have to be obeyed These are th...

Страница 4: ...d manner the user must ascertain that no danger for himself or others will result from this use He should also ascertain that the planned use will have no detrimental effect on the appliance itself Th...

Страница 5: ...on OPEN not required required for wings from2 500mm Power supply 230V 50Hz 230V 50Hz 230V 50Hz Operating voltage 24 V 24 V 24 V Duty cycle 50 50 50 Blocking when open closed Yes Yes Yes Soft Start and...

Страница 6: ...g next to the gate either with set 1 or set 2 please use the measurements in the respective installation manual Drawing 1 Drawing 2 Please make sure that the gate wings can be moved easily and that th...

Страница 7: ...5 removing of the adjustment clip Warning Please do not leave the emergency release key in the key lock Please do not remove the protective foil and the protective tape before installation has been c...

Страница 8: ...plate 3 Support profile 4 Mounting plate 5 Gate support 6 Welding profile 7 Emergency release lever 8 Adjustment clip 4 1 Tools needed The following tools are needed on site for the installation 1 Tor...

Страница 9: ...oncrete at least half way up the sides of the housing Note Do not remove the protective foil and the protective tape which covers the gap between the cover plate and the underfloor housing They protec...

Страница 10: ...below the gate support see drawing 6 Insert the key and turn it 90 anti clockwise Pull the emergency release lever downwards The gate opener is now released and the gate can be moved freely ATTENTION...

Страница 11: ...20 33 4 2 5 Installation at the gate Use the included welding profile There are 4 tapholes at one end of the welding profile The pivot point of the gate is located between these tapholes Pivot point D...

Страница 12: ...inge Place the gate with the gate support onto the gearbox shaft which protrudes from the underfloor opener Push the lever up and lock the emergency release with the key see drawing 7 Drawing 9 Move t...

Страница 13: ...opens first Max permitted force setting The original setting is force level 30 Change the force settings only when the original settings are not sufficient during learning The max permitted force set...

Страница 14: ...ton LERN on the controller for approx 2 seconds The display shows P1 h Press the button LERN again The display now shows 1F i Now select the number of gate wings Confirm the displayed 1F for one wing...

Страница 15: ...nto direction CLOSED until the end stop display P2 The gate is now in position CLOSED Should the gate now be in position OPEN the wires 4 and 5 of the motor connection cable at the 5 pin connection ha...

Страница 16: ...number of gate wings Push button BT until it displays 2F Confirm the displayed 2F for two wings with the button LERN j The display shows HA manual operation k Now you can move each gate wing separate...

Страница 17: ...o direction CLOSED until the end stop display P2 The gate is now in position CLOSED Should the gate now be in position OPEN the wires 4 and 5 of the motor connection cable at the 5 pin connection have...

Страница 18: ...ks see 4 8f Adjustment clip Gear shaft Pinion Drawing 11 For perfect operation of the gate system it is now necessary to activate the pressure relief for the electromagnetic bolt a Press the button LE...

Страница 19: ...ace the cover plate onto the underfloor housing ATTENTION Tighten the screws only 1 turn unto the point when the thread barely holds the screws Do not fasten the screws completely yet Piece by piece i...

Страница 20: ...5 pin connection FAHR or GEH f Insert the adjustment clip from above into the gate opener The level part of the adjustment clip points away from the gear shaft g Make sure the marks on the pinions and...

Страница 21: ...will have adverse effect on the motor performance Cross section 5 x 1 5 mm up to max 20 m Cross section 5 x 2 5 mm up to max 40 m Power supply 230Vac 50Hz single phase Connection By fixed wiring and...

Страница 22: ...60W timer module ASU2 radio remote control receiver LERN magnetic lock 24Vdc max 1A pedestrian wing with 24Vdc motor with pulser N PE L1 LSI LSA SLA SLZ BT BTG BA BZ __ BS __ VP LSI LSA 8 2kO 8 2kO S...

Страница 23: ...ulser for pedestrian wing IMPf pulser See motor Pulser for main wing SU Plug socket Connection for timer module ASU2 Funk Plug socket for receiver EKX1OF or receiver with decoder Integrated receiver f...

Страница 24: ...or for one winged gates SCHLOSS 3 pin Connection for electromagnetic bolt or magnetic lock with 24Vdc max 1A WARN 2 pin Potential free contact for warning light 230Vac max 60W MULTI 2 pin Potential fr...

Страница 25: ...tton LERN Sequence Function P1 Selection one wing two wings Adjusting of end stops Learning of safety contact profiles and photo cells connected Learning of running distance P2 Adjusting of force and...

Страница 26: ...push the button LERN to continue The controller tests the safety contact strips and the photo cells It learns the type of the safety contact strips 8 2 k and the number of connected photo cells Only...

Страница 27: ...for minimum speed up to 08 for maximum speed With button LERN the values may be increased with the button BTG they can be decreased Return to the learning sequence using button LERN Attention The max...

Страница 28: ...without erasing the code Radio remote control signal Receiving of a learned radio remote control signal is displayed through lighting of the right display dot 8 1 6 Sequence P6 Automatic closure for c...

Страница 29: ...ctivated Stay open time 23 seconds 23 Automatic closure is activated Stay open time 123 seconds 2 3 Automatic closure is activated Stay open time 223 seconds Table 16 Return to learning sequence using...

Страница 30: ...g button LERN The warning light is only active when a gate wing is moving and during warning prior to opening and closing Display Warning time before opening Warning time before closing 00 No warning...

Страница 31: ...esting Prior to every gate movement a photocell test may be performed The test consists of two phases During the first phase the supply of the transmitters is switched off The controller expects withi...

Страница 32: ...ing distance P1 After this please check every single photocell for proper function Remark When a faulty photo cell is detected during photo cell testing or when an obstacle is present within the photo...

Страница 33: ...A photo cell outside blocks the automatic closure function Only the signal from LSI photo cell inside removes the blocking and starts the stay open time When a vehicle passes through the gate from the...

Страница 34: ...itional safety devices like photo cells and safety contact profiles are installed at the gate When sequence PD is activated by button LERN the present selection is displayed With the button BT the val...

Страница 35: ...The controller has two integrated detectors with testing function according to EN954 1 category 2 for safety contact profiles with 8 2kOhm resistor for gate OPEN and CLOSE The status of the safety co...

Страница 36: ...n OPEN command to the controller The gate cannot be closed as long as the timer is activated After the open time has elapsed the timer sends a CLOSE command to the controller Note When the timer sends...

Страница 37: ...failed E4 Testing safety contact profile SLZ failed E5 Running distance exceeded gate was stopped Check end stoppers and re learn the running distance E6 The power supply limit for the external equip...

Страница 38: ...s should be used in such a way that the gate can be seen during movement 13 Technical data MO36 13 1 Selection range of Parameter and Original settings Constant not changeable values Parameter Origina...

Отзывы: