![Elka EST 4004K Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/elka/est-4004k/est-4004k_installation-and-operating-instructions-manual_2391222008.webp)
© 27.04.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 8
EST 4004K
BTG
Button for pedestrian opening (n.o.).
The LED BTG lights when BTG or remote button is
pressed
.
If the gate is not in the pedestrian position, BTG will move it there. If the pedestrian
opening is being used without automatic closure, then BTG works with serial switching
OPEN-STOP-CLOSE-STOP.
If automatic closure is on and the gate is at the pedestrian position, the BTG restarts the time
to stay open.
24 Vdc
Power supply for periphery equipment.
12 Vdc
Power supply for photo-cells and other external equipment.
Maximum total for both outputs
300 mA
LS-TST
Power supply for transmitter. The controller switches the 24 Vdc on terminal LS-TST off.
7.2.
Operating mode
Motor power (Changes only take effect if the running time is then learned again!)
DIP A1 OFF
100% power.
DIP A2 OFF
DIP A1 OFF
80% power.
DIP A2 ON
DIP A1 ON
70% power.
DIP A2 OFF
DIP A1 ON
60% power.
DIP A2 ON
Photo-cell (Photo-cell connected to BS is stop.)
DIP A3 OFF
The opening or closing gate stops when the photo-cell is interrupted and opens when the
DIP A4 OFF
photo-cell is free.
DIP A3 OFF
The closing gate stops and opens immediately when the photo-cell is interrupted.
DIP A4 ON
The opening gate is not effected.
DIP A3 ON
The closing gate stops when the photo-cell is interrupted and carries on closing when the
DIP A4 OFF
photo-cell is free. The opening gate is not effected.