Example C) Combination of examples A and B

 

 

A garage door opener with MO 55 and a swing gate opener with either MO 32 or MO 33.

 

 

1.)  Set the code of the transmitter and receiver for the swing gate opener as described above. Switches 1 
 

to 7 have the same settings in both transmitter and receiver. The switches 8 and 9 set at 0.

 

 

The swing gate opener now receives signals from the first button of the transmitter. 

 

2.) You can now allocate the second button to the garage door opener by going through the procedure  
 

described in the installation instructions for the garage door opener in the paragraph ‘Learning  

 personal 

code’.

 

 
 

11. General Notes to Safety

 

 

These operating instructions must be available on site at all times. It should be read thoroughly by all 
persons who use, or service the appliances. Improper usage or servicing or ignoring the operating 
instructions can be a source of danger for persons, or result in material damage. If the meaning of any part 
of these instructions isn’t clear, then please contact ELKA Torantriebe GmbH & Co. Betriebs KG before you 
use the appliance. 
This applies to all setup procedures, fault finding, disposal of material, care and servicing of the appliance. 
The accident prevention regulations and applicable technical regulations (e.g. safety or electrical) and 
environment protection regulations of the country in which the appliance is used also apply. 
All repairs on the appliances must be carried out by qualified persons. ELKA Torantriebe GmbH & Co. 
Betriebs KG accepts no liability for damage which is caused by using the appliance for purposes other than 
those for which it is built. 
ELKA Torantriebe GmbH & Co. Betriebs KG cannot recognise every possible source of danger in advance. If 
the appliance is used other than in the recommended manner, the user must ascertain that no danger for 
himself or others will result from this use. He should also ascertain that the planned use will have no 
detrimental effect on the appliance itself. The appliance should only be used when all safety equipment is 
available and in working order. All faults which could be a source of danger to the user or to third persons 
must be eliminated immediately. All Warning and Safety notices on the appliances must be kept readable. 
All electrical periphery equipment which is connected to the appliance must have a CE Mark, which ensures 
that it conforms to the relevant EEC regulations. Neither mechanical nor electrical alterations to the 
appliance, without explicit agreement of the manufacturer, are allowed. All alterations or extensions to the 
appliance must be carried out with parts which ELKA Torantriebe GmbH & Co. Betriebs KG have defined as 
suitable for such alterations, and be carried out by qualified personnel.  
Any contravention of these conditions revokes the manufacturer’s guarantee and also the CE Mark and the 
user is alone responsible for the consequences. 
Our service department is available to answer all queries about these conditions and, of course, about our 
appliances. 
 
 
 
 
 
 

We reserve the right to make technical improvements without prior notice. 

The operation of the system within CEN countries must also be conformant with the European safety-
relevant directives and standards. 

Содержание EST 4004K

Страница 1: ...ST 4004K Contents Page 1 Usage 2 2 Technical data 2 3 Measurements 2 4 Installation 3 4 1 Emergency release 4 5 Electrical connections 4 6 Connection example 5 7 MO 44 2 Controller 6 7 1 Connections 7...

Страница 2: ...ply 400 Vac 50 Hz Power consumption 2 2 kW Control box MO44 2 Electronic brake no The MO 44 2 control box has among others the following characteristics Safety Four separate reactions to the photo cel...

Страница 3: ...on parallel to the gate at a distance of 60 mm Mark the middle of each hole on the foundation e Fix the opener either with plugs and screws M20 or with heavy duty tie bolts e Decide at what height the...

Страница 4: ...ose the gate and push the holding plate with magnet along the rack until the LED SEZ turns off Fix the holder at this point on the rack so that the magnet passes the housing at a distance of about 10...

Страница 5: ...27 04 2005 ELKA Torantriebe GmbH u Co Betriebs KG Page 5 EST 4004K 6 Connection example...

Страница 6: ...27 04 2005 ELKA Torantriebe GmbH u Co Betriebs KG Page 6 EST 4004K 2T1 1L1 1L1 2T1 14NO 6T3 4T2 A2 13NO 5L3 3L2 K2 A1 6T3 4T2 14NO A2 5L3 3L2 K1 13NO A1 loop BA1 STOP START 7 MO 44 2 Controller...

Страница 7: ...itted to terminal EXT AUF The LED BA lights if BA1 or the corresponding remote button is pressed A permanent open signal is possible BA2 Button to open the gate n o the signal is valid only for this c...

Страница 8: ...tputs 300 mA LS TST Power supply for transmitter The controller switches the 24 Vdc on terminal LS TST off 7 2 Operating mode Motor power Changes only take effect if the running time is then learned a...

Страница 9: ...when the gate is open The gate reopens if BT is pressed during closing Warning prior to opening DIP B1 OFF No warning DIP B1 ON The warning light is switched on 4 seconds before the gate opens Warnin...

Страница 10: ...e relay connections of the receivers have to be connected in series Parallel to the relay connections a resistor of 1kOhm 5 each has to be connected The photo cell test consists of two parts The trans...

Страница 11: ...N until the LED DIAG lights approx 3 seconds Press LERN twice The gate closes from any position opens completely and closes again The time required and the power selected DIP A1 and DIP A2 are then sa...

Страница 12: ...The LED DIAG stays on as long as a signal is received Release the button The code is stored and the controller is ready for use 8 Timer card optional The 7 day timer can switch between day and night...

Страница 13: ...DIAG 11 flashes The controller has detected a fault in the redundant detection of BS stop contact The controller is faulty DIAG 12 flashes The controller detects that the TRIAC or one of motor relays...

Страница 14: ...e GmbH Co Betriebs KG accepts no liability for damage which is caused by using the appliance for purposes other than those for which it is built ELKA Torantriebe GmbH Co Betriebs KG cannot recognise e...