![Elka EST 4004K Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/elka/est-4004k/est-4004k_installation-and-operating-instructions-manual_2391222012.webp)
© 27.04.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 12
EST 4004K
Learning the remote control code for BT
Press LERN until the LED DIAG lights (approx. 3 seconds).
Press BT once. The LED DIAG flashes quickly. Press the appropriate button of your transmitter.
The LED DIAG stays on as long as a signal is received. Release the button. The code is stored and the
controller is ready for use.
Learning the remote control code for BTG
Press LERN until the LED DIAG lights (approx. 3 seconds).
Press BTG once. The LED DIAG flashes quickly. Press the appropriate button of your transmitter.
The LED DIAG stays on as long as a signal is received. Release the button. The code is stored and the
controller is ready for use.
Learning the remote control code for BA1
Press LERN until the LED DIAG lights (approx. 3 seconds).
Press LERN once. The LED DIAG flashes quickly. Press the appropriate button of your transmitter.
The LED DIAG stays on as long as a signal is received. Release the button. The code is stored and the
controller is ready for use.
8. Timer card (optional)
The 7-day-timer can switch between day and night operating.
Day:
A continuous signal to open is given in order to hold the sliding gate open. All Signals from BA1 are
sent to EXT-AUF for a further control box.
Night:
All signals from BA1 operate the sliding gate and are sent to EXT-AUF for a further control box.
Holidays:
The switch NB (night operation) can override the timer. If NB is closed, night operation is active
independent of the status of the timer. The timer has control when NB is open.
Forcing day operation at night:
A continuous signal to BA2 opens the sliding gate and keeps it open
independent of the timer status.
Times NB
Gate
status
Off
Doesn’t matter Does not affect the gate
Switches on
Off
The gate opens
On
Off
The gate is held open
Switches off
Off
The gate closes
On
Switches on
The gate closes, night operation is forced
On
Switches off
The gate opens, day operation is continued
Doesn’t matter On
Does not affect the gate