background image

M1XSLZW   Instruction  Manual

Page 16

Below are Elk-RP Rule examples being used to control Lights, Thermostats, and Locks.  

STEP 7 - Rule Examples and Advanced M1XSLZW Options

Rule 1 - Activates Save Energy 
Task* when Armed Away.

Rule 2 - Task* "Save Energy" 

turns off lights and sets back 

HVAC (Thermostat) to save $$.

Rule 3 - Activates Welcome 
Home Task* when Disarmed.

Rule 4 - Task* "Welcome Home" 
turns on some lights and sets 
HVAC to 69 & 72 deg. 

Rule 5 - Task* "At Home" adjusts 

lights in Groups.

Rule 6 - Locks door #1 as soon 

as exit delay expires following 
System Arming.

Rule 7 - Locks door #1 just 

as soon as Front Door closes 
following System Arming.  The 
door will get locked no matter 

whether Rule 6 or 7 fires first.

Rule 8 - Turns on Foyer Lights 
when entry delay begins AND it 
is dark outside.

Rule 9 - Turns on Hallway light-

ing Group when hallway motion 

is detected.

Rule 10 - Automatically turns 

some lights Off at 11:00PM.

Rule 11 - Turns Out15 ON 

when  text string  <LOCK1^M 

is received.  Another rule is 

needed to turn Out15 OFF when 

<ULOCK1^M is received.

* Tasks are like macros and can 
be handy for optimizing or saving 
rule space.  The same task can 
be activated by any of several 
rules and conditions.

Содержание ELK-M1XSLZW

Страница 1: ...3 is known as a Z Wave Secondary Controller It is required as a permanent member of the Z Wave network to maintain contact with all Z Wave devices and communicate via RS232 to the M1XSLZW The M1XSLZW...

Страница 2: ...viton web site links http www leviton com OA_HTML ibeCCtpSctDspRte jsp section 25545 minisite 10024 http communities leviton com docs DOC 2389 http communities leviton com community knowledgebaseforum...

Страница 3: ...The Dimmers will not react to a button press if not associated NOTE Not all Z Wave devices support full association Update Controller Updating transfers existing Node ID information associations rout...

Страница 4: ...61 62 63 64 Name or Description of Device This page is provided for listing all the Z Wave Devices their names and device types Device Type Z Wave Node ID 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79...

Страница 5: ...24hours Next turn on the M1 Master Power Switch which will then supply power to the M1XSLZW 7 Enroll the M1XSLZW to the M1 Control REQUIRED This is done either via a Keypad or ElkRP Software From a Ke...

Страница 6: ...a new Rule E G Turn OFF several Z Wave Lights when the System is Armed Away 3 13 Click WHENEVER Security Alarms Is Armed Armed Away A pop up box appears to pick the Area partition Use the drop down t...

Страница 7: ...A16 17 B1 18 B2 19 B3 20 B4 21 B5 22 B6 23 B7 24 B8 25 B9 26 B10 Z Wave Node ID 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 ELK Lighting Device 27 B11 28 B12 29 B13...

Страница 8: ...k mark in the Show box IF the Group will need to be displayed on touchscreens or keypads 4 10 Voice Description is optional Up to 6 words may be used to provide a spoken description for each Group Con...

Страница 9: ...ify they are set as follows UART Settings 9600 Baud rate 8 Data bits No Parity 1 Stop bit No Flow Control Properties ASCII Setup Send line ends with line feeds Yes and Echo type characters locally Yes...

Страница 10: ...ustomer wants the Thermostats to appear in a desired order then it will be necessary to perform the Z Wave Inclusion in exactly that desired order That s because the order of mapping in M1 is based so...

Страница 11: ...elow 5 12 To set the Cooling setpoint click THEN Thermostat 5 13 Select the same Thermostats E G Main Hallway Tstat 1 as before 5 14 Click Set cooling desired temperature to 5 15 In the value box scro...

Страница 12: ...a THEN Send Text to Port X command in an ElkRP Rule The Text will be your command and the Port X will be the Data Bus Address of the M1XSLZW Mapping of the locks is done by the M1XSLZW on power up usi...

Страница 13: ...result each lock command will require a dedicated rule In addition no other THEN commands should exist in a rule that is being used for Locks Z Wave Locks use a special encrypted Security Class for c...

Страница 14: ...nts of low battery alert through the use of automation rules and special text strings This new capability was added in M1XSLZW firmware version 81 0 4 1 Select ElkRP Automation Texts and add the follo...

Страница 15: ...ity or operation of electronic locks It is the sole responsibility of the Installing Company or Individual to use best judgment when remotely controlling or automating door locks CONFIRMING LOCK STATU...

Страница 16: ...or 1 as soon as exit delay expires following System Arming Rule 7 Locks door 1 just as soon as Front Door closes following System Arming The door will get locked no matter whether Rule 6 or 7 fires fi...

Страница 17: ...text TPOLL M DO NOT use the polling if not absolutely necessary as it does create excessive traffic XPOLL M Text string XPOLL M informs the M1XSLZW to stop the timed polling of Thermostats if enabled...

Страница 18: ...M1XSLZW Instruction Manual Page 18 PO Box 100 3266 US Hwy 70 West Hildebran NC 28637 828 397 4200 828 397 4415 Fax http www elkproducts com...

Отзывы: