background image

L638  2/20/2018  

Printed in USA

Specifications are Subject to Change without notice.

NOTICE: Drawings, illustrations, diagrams, part numbers, etc. are 

provided as reference only and are based on equipment available at 

the time the information was created.  All information contained in this 

document are subject to change without notice. 

The extent of integration between Elk Products and Partner Mfgs varies, 

and there may be situations or limitations beyond Elk's control that make 

certain desirable features unavailable or unusable.  Partner products 

and/or protocols, including Elk's may not contain the capabilities or 

data definitions to permit additional integration beyond what is currently 

available.  Partners may also, at their option, add, modify, or discontinue 

features or support without notification.  

For reasons stated herein, Elk Products makes no warranty that it will 

be able to integrate all available features or operations, nor does it make 

any express or implied warranties of fitness for a particular purpose or of 

merchantability.  Refer to Elk's Limited Warranty. 

APPLICATION & OVERVIEW:

The 

M1XSLZW 

is a specialized Elk-M1 serial expander for 

connecting M1 Controls to Z-Wave enabled devices through a 
Leviton VRC0P-1LW (vizia rf+3) Z-Wave Serial Interface.  
Z-Wave is a wireless, low power, "mesh" network technology 
widely used for automating devices such as: Lights, Thermostats, 
Electronic Locks, etc.  Z-Wave empowers devices to be remotely 

controlled from across the room or across the world with benefits 

such as energy savings, convenience, and comfort.

The VRC0P-1LW (vizia rf+3)  is known as a Z-Wave Secondary 
Controller.  It is required as a permanent member of the Z-Wave 
network to maintain contact with all Z-Wave devices and 
communicate via RS232 to the M1XSLZW.  The M1XSLZW 
translates the protocol into the M1 control and allows commands 
to be sent and received on the Z-Wave network.

Functionally the M1XSLZW is a serial expander (RS485 to 
RS232) and shares the same TYPE 5 databus ID as M1XSP serial 
expanders.  A maximum of seven (7) TYPE 5 serial expanders 
may be connected to an M1.    

A key benefit of combining the M1XSLZW and VRCOP-1LW  

(vizia rf+3) is the  ability to interface with new generation Z-Wave 
devices such as the electronic deadbolts and locksets from 
Kwikset, Yale, and Schlage.  Locks require a special Security 
Encrypted (SE) protocol and a process called "Beaming".  Both 
the M1XSLZW and the VRC0P-1LW (vizia rf+3) support these 
new requirements. 

In general, any Z-Wave device that is compatible with the Levitons 
VRC0P-1LW (vizia rf+3) should also be compatible with the M1.  
However some devices may have limited functionality due to 

design or feature differences.     

SPECIFICATIONS:

 Activity/Status LED (Orange)

 Auto-Reset Hardware Watchdog Circuit

 Addressable (1-7) TYPE 5 Databus ID

 Operating Voltage: 12 Volts D.C.

 Current Draw: 31mA

 Housing: 

4.25" x 6.375" x 2.125"

 Circuit Board: 2.75" x 3.95"

 Connection to VRC0P-1LW: DB9M 9 Pin Port

 Connection to M1: Elevator Screw Terminals (4)

ELK-M1XSLZW

M1 to Leviton Z-Wave Interface

INSTRUCTIONS

NOTE: The Leviton VRC0P-1LW (vizia rf+3), also known as 

a VRC0P+3 is not included with the M1XSLZW.  It must be 
purchased separately from a Leviton stocking Distributor.  
When ordering Specify Leviton Part Number: VRC0P-1LW

 

2013 Elk Products Inc.  All rights reserved.

 

Leviton and are registered trademarks of 
Leviton Manufacturing Co. Inc. 

Содержание ELK-M1XSLZW

Страница 1: ...3 is known as a Z Wave Secondary Controller It is required as a permanent member of the Z Wave network to maintain contact with all Z Wave devices and communicate via RS232 to the M1XSLZW The M1XSLZW...

Страница 2: ...viton web site links http www leviton com OA_HTML ibeCCtpSctDspRte jsp section 25545 minisite 10024 http communities leviton com docs DOC 2389 http communities leviton com community knowledgebaseforum...

Страница 3: ...The Dimmers will not react to a button press if not associated NOTE Not all Z Wave devices support full association Update Controller Updating transfers existing Node ID information associations rout...

Страница 4: ...61 62 63 64 Name or Description of Device This page is provided for listing all the Z Wave Devices their names and device types Device Type Z Wave Node ID 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79...

Страница 5: ...24hours Next turn on the M1 Master Power Switch which will then supply power to the M1XSLZW 7 Enroll the M1XSLZW to the M1 Control REQUIRED This is done either via a Keypad or ElkRP Software From a Ke...

Страница 6: ...a new Rule E G Turn OFF several Z Wave Lights when the System is Armed Away 3 13 Click WHENEVER Security Alarms Is Armed Armed Away A pop up box appears to pick the Area partition Use the drop down t...

Страница 7: ...A16 17 B1 18 B2 19 B3 20 B4 21 B5 22 B6 23 B7 24 B8 25 B9 26 B10 Z Wave Node ID 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 ELK Lighting Device 27 B11 28 B12 29 B13...

Страница 8: ...k mark in the Show box IF the Group will need to be displayed on touchscreens or keypads 4 10 Voice Description is optional Up to 6 words may be used to provide a spoken description for each Group Con...

Страница 9: ...ify they are set as follows UART Settings 9600 Baud rate 8 Data bits No Parity 1 Stop bit No Flow Control Properties ASCII Setup Send line ends with line feeds Yes and Echo type characters locally Yes...

Страница 10: ...ustomer wants the Thermostats to appear in a desired order then it will be necessary to perform the Z Wave Inclusion in exactly that desired order That s because the order of mapping in M1 is based so...

Страница 11: ...elow 5 12 To set the Cooling setpoint click THEN Thermostat 5 13 Select the same Thermostats E G Main Hallway Tstat 1 as before 5 14 Click Set cooling desired temperature to 5 15 In the value box scro...

Страница 12: ...a THEN Send Text to Port X command in an ElkRP Rule The Text will be your command and the Port X will be the Data Bus Address of the M1XSLZW Mapping of the locks is done by the M1XSLZW on power up usi...

Страница 13: ...result each lock command will require a dedicated rule In addition no other THEN commands should exist in a rule that is being used for Locks Z Wave Locks use a special encrypted Security Class for c...

Страница 14: ...nts of low battery alert through the use of automation rules and special text strings This new capability was added in M1XSLZW firmware version 81 0 4 1 Select ElkRP Automation Texts and add the follo...

Страница 15: ...ity or operation of electronic locks It is the sole responsibility of the Installing Company or Individual to use best judgment when remotely controlling or automating door locks CONFIRMING LOCK STATU...

Страница 16: ...or 1 as soon as exit delay expires following System Arming Rule 7 Locks door 1 just as soon as Front Door closes following System Arming The door will get locked no matter whether Rule 6 or 7 fires fi...

Страница 17: ...text TPOLL M DO NOT use the polling if not absolutely necessary as it does create excessive traffic XPOLL M Text string XPOLL M informs the M1XSLZW to stop the timed polling of Thermostats if enabled...

Страница 18: ...M1XSLZW Instruction Manual Page 18 PO Box 100 3266 US Hwy 70 West Hildebran NC 28637 828 397 4200 828 397 4415 Fax http www elkproducts com...

Отзывы: