Elk Products ELK-M1XSP Скачать руководство пользователя страница 15

M1XSP  Installation Manual

Page 15

UPB

Switch 1
Switch 2
Switch 3
Switch 4
Switch 5
Switch 6
Switch 7
Switch 8
Switch 9

Switch 10
Switch 11
Switch 12
Switch 13
Switch 14
Switch 15
Switch 16
Switch 17
Switch 18
Switch 19
Switch 20
Switch 21
Switch 22
Switch 23
Switch 24
Switch 25
Switch 26
Switch 27
Switch 28
Switch 29
Switch 30
Switch 31
Switch 32
Switch 33
Switch 34
Switch 35
Switch 36
Switch 37
Switch 38
Switch 39
Switch 40
Switch 41
Switch 42
Switch 43
Switch 44
Switch 45
Switch 46
Switch 47
Switch 48
Switch 49
Switch 50
Switch 51
Switch 52
Switch 53
Switch 54
Switch 55
Switch 56
Switch 57
Switch 58
Switch 59
Switch 60
Switch 61
Switch 62
Switch 63
Switch 64

ELK

Light

Device #

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64

PLC

(X-10)

Ref.

A01
A02
A03
A04
A05
A06
A07
A08
A09
A10
A11
A12
A13
A14
A15
A16
B01
B02
B03
B04
B05
B06
B07
B08
B09
B10
B11
B12
B13
B14
B15
B16
C01
C02
C03
C04
C05
C06
C07
C08
C09
C10
C11
C12
C13
C14
C15
C16
D01
D02
D03
D04
D05
D06
D07
D08
D09
D10
D11
D12
D13
D14
D15
D16

UPB

Switch 65
Switch 66
Switch 67
Switch 68
Switch 69
Switch 70
Switch 71
Switch 72
Switch 73
Switch 74
Switch 75
Switch 76
Switch 77
Switch 78
Switch 79
Switch 80
Switch 81
Switch 82
Switch 83
Switch 84
Switch 85
Switch 86
Switch 87
Switch 88
Switch 89
Switch 90
Switch 91
Switch 92
Switch 93
Switch 94
Switch 95
Switch 96
Switch 97
Switch 98
Switch 99

Switch 100
Switch 101
Switch 102
Switch 103
Switch 104
Switch 105
Switch 106
Switch 107
Switch 108
Switch 109
Switch 110
Switch 111
Switch 112
Switch 113
Switch 114
Switch 115
Switch 116
Switch 117
Switch 118
Switch 119

Load 120
Load 121
Load 122
Load 123
Load 124
Load 125
Load 126
Load 127
Load 128

ELK

Light

Device #

65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99

100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128

PLC

(X-10)

Ref.

E01
E02
E03
E04
E05
E06
E07
E08
E09
E10
E11
E12
E13
E14
E15
E16
F01
F02
F03
F04
F05
F06
F07
F08
F09
F10
F11
F12
F13
F14
F15
F16

G01
G02
G03
G04
G05
G06
G07
G08
G09
G10
G11
G12
G13
G14
G15
G16
H01
H02
H03
H04
H05
H06
H07
H08
H09
H10
H11
H12
H13
H14
H15
H16

ELK

Light

Device #

129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192

PLC

(X-10)

Ref.

I01
I02
I03
I04
I05
I06
I07
I08
I09
I10
I11
I12
I13
I14
I15
I16

J01
J02
J03
J04
J05
J06
J07
J08
J09
J10
J11
J12
J13
J14
J15
J16

K01
K02
K03
K04
K05
K06
K07
K08
K09
K10
K11
K12
K13
K14
K15
K16

L01
L02
L03
L04
L05
L06
L07
L08
L09
L10
L11
L12
L13
L14
L15
L16

ELK

Light

Device #

193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256

UPB

Switch 129
Switch 130
Switch 131
Switch 132
Switch 133
Switch 134
Switch 135
Switch 136
Switch 137
Switch 138
Switch 139
Switch 140
Switch 141
Switch 142
Switch 143
Switch 144
Switch 145
Switch 146
Switch 147
Switch 148
Switch 149
Switch 150
Switch 151
Switch 152
Switch 153
Switch 154
Switch 155
Switch 156
Switch 157
Switch 158
Switch 159
Switch 160
Switch 161
Switch 162
Switch 163
Switch 164
Switch 165
Switch 166
Switch 167
Switch 168
Switch 169
Switch 170
Switch 171
Switch 172
Switch 173
Switch 174
Switch 175
Switch 176
Switch 177
Switch 178
Switch 179
Switch 180
Switch 181
Switch 182
Switch 183
Switch 184
Switch 185
Switch 186
Switch 187
Switch 188
Switch 189
Switch 190
Switch 191
Switch 192

UPB

Link (Scene) 01
Link (Scene) 02
Link (Scene) 03

 Link (Scene) 04

Link (Scene) 05
Link (Scene) 06
Link (Scene) 07
Link (Scene) 08
Link (Scene) 09
Link (Scene) 10
Link (Scene) 11
Link (Scene) 12
Link (Scene) 13
Link (Scene) 14
Link (Scene) 15
Link (Scene) 16
Link (Scene) 17
Link (Scene) 18
Link (Scene) 19
Link (Scene) 20
Link (Scene) 21
Link (Scene) 22
Link (Scene) 23
Link (Scene) 24
Link (Scene) 25
Link (Scene) 26
Link (Scene) 27
Link (Scene) 28
Link (Scene) 29
Link (Scene) 30
Link (Scene) 31
Link (Scene) 32
Link (Scene) 33
Link (Scene) 34
Link (Scene) 35
Link (Scene) 36
Link (Scene) 37
Link (Scene) 38
Link (Scene) 39
Link (Scene) 40
Link (Scene) 41
Link (Scene) 42
Link (Scene) 43
Link (Scene) 44
Link (Scene) 45
Link (Scene) 46
Link (Scene) 47
Link (Scene) 48
Link (Scene) 49
Link (Scene) 50
Link (Scene) 51
Link (Scene) 52
Link (Scene) 53
Link (Scene) 54
Link (Scene) 55
Link (Scene) 56
Link (Scene) 57
Link (Scene) 58
Link (Scene) 59
Link (Scene) 60
Link (Scene) 61
Link (Scene) 62
Link (Scene) 63

** Link (Scene) 64 Alarm Flash

PLC

(X-10)

Ref.

M01
M02
M03
M04
M05
M06
M07
M08
M09
M10
M11
M12
M13
M14
M15
M16

N01
N02
N03
N04
N05
N06
N07
N08
N09
N10
N11
N12
N13
N14
N15
N16
O01
O02
O03
O04
O05
O06
O07
O08
O09
O10
O11
O12
O13
O14
O15

016

P01
P02
P03
P04
P05
P06
P07
P08
P09
P10
P11
P12
P13
P14
P15
P16

The PLC column is for reference only.

M1 Lighting Devices Mapped to UPB

** Link (Scene) 64: When this link is activated from the M1, the M1 will automatically send a special "flash" command.  All devices

are programmed to respond to Link 64 will immediately begin flashing until the link is de-activated (turned off) from the M1.

UPB - (continued)

Содержание ELK-M1XSP

Страница 1: ...the capabilities or data definitions to permit additional integration beyond what is currently available In addition Partner Mfgs may at their option add modify or discontinued features or support wit...

Страница 2: ...ettings via DIP Switches Jumper Options and LED Diagnostic indicator On Board EOL Bus Termination Jumper Flash Memory for Firmware Updating SPECIFICATIONS Maximum of Expandable Ports Units 7 with M1G...

Страница 3: ...HAI Thermostats numbered 1 thru 4 Data bus address 2 for HAI Thermostats numbered 5 to 8 Data bus address 3 for HAI Thermostats numbered 9 to 12 Data bus address 4 for HAI Thermostats numbered 13 to 1...

Страница 4: ...AI OnQ ALC UPB Centralite EDT Dynalite LutronRA W800RF32 etc 10 x x Field Installable Firmware Uplink AnyNet and AES Intellinet Radio 20 x x Field Installable Firmware Vizia RZCOP ZWave interface Down...

Страница 5: ...Aprilaire baud rate is preset internally 4 Plug the Aprilaire supplied 6 ft RJ to DB9 Cable between the 8811 Protocol Adapter and the ELK M1XSP DO NOT USE THE ELK WO37A CABLE 5 Power up the Aprilaire...

Страница 6: ...unit The White Yellow wire is optional It may be used to supply 12VDC from the M1XSP to the Thermostat in lieu of the HVAC power Consult the RCS manual for details Plug the other end of the ELK WO37A...

Страница 7: ...preset internally 4 Using a 3 conductor cable and the diagram below connect the GND D and D wires from the RS 485 terminals on the RCS Thermostat Control unit to the RS 485 terminals on the M1XSP The...

Страница 8: ...OmniStat 2 series the M1XSP must be firmware updated to version 70 0 2 or the latest 70 x x version 4 Set the M1XSP MODE jumpers to S5 1 S6 0 S7 1 S8 0 If the M1XSP has jumper S4 set it to 1 5 Set th...

Страница 9: ...Data Bus Terminals VKP A B Neg ADDRESS Only Addresses 1 2 3 or 4 can be used with HAI Stats Address 1 shown Switch 1 on MODE For HAI set to 1010 1 0 Address 1 2 4 8 ELK M1XSP Interface 1 0 1 2 3 4 RS...

Страница 10: ...assigned to Carrier System 2 Zone 2 Elk Thermostat 3 is assigned to Carrier System 1 Zone 3 Elk Thermostat 11 is assigned to Carrier System 2 Zone 3 Elk Thermostat 4 is assigned to Carrier System 1 Z...

Страница 11: ...T FORGET TO ENROLL THE M1XSP INTO THE M1 9 Program and test at least one light device using the ELK RP Software and the following steps 9a Click on the Automation icon then on the Lighting icon 9b Cli...

Страница 12: ...only support ALC 4 button scene switches wired and connected on ALC branch 1 Setting up the M1XSP and the M1 to communicate with OnQ ALC 1 Install the ELK M1XSP per the instructions on page 3 Be sure...

Страница 13: ...4 F15 F16 G01 G02 G03 G04 G05 G06 G07 G08 G09 G10 G11 G12 G13 G14 G15 G16 H01 H02 H03 H04 H05 H06 H07 H08 H09 H10 H11 H12 H13 H14 H15 H16 ELK Light Device 129 130 131 132 133 134 135 136 137 138 139 1...

Страница 14: ...individual addresses program M1 Lighting devices 1 192 as Format Serial Expander Type Dimmer or On Off Switch if the device isn t dimmable For UPB link addresses program M1 Lighting devices 193 256 a...

Страница 15: ...1 192 PLC X 10 Ref I01 I02 I03 I04 I05 I06 I07 I08 I09 I10 I11 I12 I13 I14 I15 I16 J01 J02 J03 J04 J05 J06 J07 J08 J09 J10 J11 J12 J13 J14 J15 J16 K01 K02 K03 K04 K05 K06 K07 K08 K09 K10 K11 K12 K13 K...

Страница 16: ...pander Type On Off Switch Load Status and or Limitations with Elegance and LiteJet The wallplate button press feature with LiteJet Elegance is not directly usable with M1 However by assigning a button...

Страница 17: ...172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 PLC X 10 Ref I01 I02 I03 I04 I05 I06 I07 I08 I09 I10 I11 I12 I13 I14 I15 I16 J01 J02 J03 J04 J05 J06 J07 J08 J09 J10...

Страница 18: ...nd 17 All On All Off respectively Program the name for light device 16 as All On Off Set the Format to Serial Expander and Type to On Off Switch Activating M1 lighting 16 On it will send Phantom 16 Ac...

Страница 19: ...2 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 PLC X 10 Ref I01 I02 I03 I04 I05 I06 I07 I08 I09 I10 I11 I12 I13 I14 I15 I16 J...

Страница 20: ...nked learned into the M1XSP starting at the first M1 Lighting device 001 A1 Using just the M1XSP there is no way to have devices start at a specific location INSTEON devices cannot be removed or re ar...

Страница 21: ...e Right arrow key to access Menu 1 View Control Automation Fncts Press 2 followed by the right arrow key for the Lighting sub menu Advance to M1 Light 256 INSTEON LinkMode by entering 2 5 6 2 Turn ON...

Страница 22: ...s an option to eliminate Groups and free up addresses 193 M1 to 254 P14 See note N2 below N1 With the M1XSP Jumper S5 0 factory setting the M1XSP supports a total of 192 individual INSTEON or X 10 Lig...

Страница 23: ...H14 H15 H16 ELK Light Device 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 17...

Страница 24: ...s c RS 232 Setup this may show up as HAI SETUP in some older remotes For helpful information about the ViziaRF configuration use the following link to the Leviton web site http www leviton com OA_HTML...

Страница 25: ...be set as Backup B Optional Program a name to describe the location that this telephone number is reporting to C Do not program any numbers into the NUMBER TO DIAL location D Program the reporting for...

Страница 26: ...ignals onto the AC powerline if equipped with a PSC05 PLC interface Please note that M1 rules can only be activated by ON or OFF commands from these devices There is no rule activation support for DIM...

Страница 27: ...the AES Radio to be positioned far from the control 6 Construct a Serial Connection Cable from the M1XSP to the AES Radio Unit using the diagram below This cable requires a DB9F 9 Pin Female connecto...

Страница 28: ...ING ELKRP SOFTWARE MAKE SURE TO SEND ALL OF THIS PROGRAMMING TO THE CONTROL 10 Test Test Test It is very important to test each of the reported events SUPERVISION The M1XSP is enrolled with M1 Control...

Страница 29: ...esignated A and A1 Do the same for the data B White wire At the control splice the A1 and B1 wires to the A and B wires going to the next device Terminate the last wired device and the control JP3 ONL...

Страница 30: ...keys to exit Installer Programming 1234567890123456789012345 1234567890123456789012345 1234567890123456789012345 1234567890123456789012345 1234567890123456789012345 1234567890123456789012345 12345678...

Страница 31: ...M1XSP InstallationManual Page 31 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 32: ...engage a 120 Ohm resistor for terminating the M1 RS 485 Data Bus See M1 Data bus wiring instructions before use JP2 Used to engage a 120 Ohm resistor for terminating the Outbound External RS 485 Data...

Отзывы: