Elk Products ELK-M1XSP Скачать руководство пользователя страница 1

ELK-M1XSP

Lighting Interface, Thermostat Interface,

and Serial Port Expander

INSTALLATION

MANUAL

M1XSP  Rev. G  5/2/2011

Printed in USA

PO Box 100

3266 US Hwy 70 West

Hildebran, NC  28637

828-397-4200   828-397-4415 Fax

http://www.elkproducts.com

IMPORTANT NOTICE: Every effort has been made to assure the accuracy of the information contained in this docu-
ment as of the date printed.

The extent of integration between Elk Products and other Partner Mfgs varies from product to product.  Some integra-
tion is more powerful or feature rich than others.  In some cases there are variables or limitations not within Elk's
control which may render certain desirable features unavailable or unusable.  Certain  Partner Mfgs products and/or
protocols, including Elk's may not contain the capabilities or data definitions to permit additional integration beyond
what is currently available.  In addition, Partner Mfgs may, at their option, add, modify, or discontinued features or
support with little or no notification.

Drawings, illustrations, diagrams, part numbers, etc. contained and shown in this document are provided as refer-
ence only.  All information is based on equipment available from or provided by the Partner Mfg. at the time the
information was created.  A Partner Mfg may in fact offer similar or alternative equipment in their line that Elk has not
evaluated, and therefore Elk cannot guarantee operational compatibility.

For reasons stated herein, Elk Products makes no warranty that it will be able to integrate all available features or
operations, nor does it make any express or implied warranties of fitness for a particular purpose or of merchantability.
Refer to Elk's Limited Warranty.

Specifications are Subject to Change without notice.

Содержание ELK-M1XSP

Страница 1: ...the capabilities or data definitions to permit additional integration beyond what is currently available In addition Partner Mfgs may at their option add modify or discontinued features or support wit...

Страница 2: ...ettings via DIP Switches Jumper Options and LED Diagnostic indicator On Board EOL Bus Termination Jumper Flash Memory for Firmware Updating SPECIFICATIONS Maximum of Expandable Ports Units 7 with M1G...

Страница 3: ...HAI Thermostats numbered 1 thru 4 Data bus address 2 for HAI Thermostats numbered 5 to 8 Data bus address 3 for HAI Thermostats numbered 9 to 12 Data bus address 4 for HAI Thermostats numbered 13 to 1...

Страница 4: ...AI OnQ ALC UPB Centralite EDT Dynalite LutronRA W800RF32 etc 10 x x Field Installable Firmware Uplink AnyNet and AES Intellinet Radio 20 x x Field Installable Firmware Vizia RZCOP ZWave interface Down...

Страница 5: ...Aprilaire baud rate is preset internally 4 Plug the Aprilaire supplied 6 ft RJ to DB9 Cable between the 8811 Protocol Adapter and the ELK M1XSP DO NOT USE THE ELK WO37A CABLE 5 Power up the Aprilaire...

Страница 6: ...unit The White Yellow wire is optional It may be used to supply 12VDC from the M1XSP to the Thermostat in lieu of the HVAC power Consult the RCS manual for details Plug the other end of the ELK WO37A...

Страница 7: ...preset internally 4 Using a 3 conductor cable and the diagram below connect the GND D and D wires from the RS 485 terminals on the RCS Thermostat Control unit to the RS 485 terminals on the M1XSP The...

Страница 8: ...OmniStat 2 series the M1XSP must be firmware updated to version 70 0 2 or the latest 70 x x version 4 Set the M1XSP MODE jumpers to S5 1 S6 0 S7 1 S8 0 If the M1XSP has jumper S4 set it to 1 5 Set th...

Страница 9: ...Data Bus Terminals VKP A B Neg ADDRESS Only Addresses 1 2 3 or 4 can be used with HAI Stats Address 1 shown Switch 1 on MODE For HAI set to 1010 1 0 Address 1 2 4 8 ELK M1XSP Interface 1 0 1 2 3 4 RS...

Страница 10: ...assigned to Carrier System 2 Zone 2 Elk Thermostat 3 is assigned to Carrier System 1 Zone 3 Elk Thermostat 11 is assigned to Carrier System 2 Zone 3 Elk Thermostat 4 is assigned to Carrier System 1 Z...

Страница 11: ...T FORGET TO ENROLL THE M1XSP INTO THE M1 9 Program and test at least one light device using the ELK RP Software and the following steps 9a Click on the Automation icon then on the Lighting icon 9b Cli...

Страница 12: ...only support ALC 4 button scene switches wired and connected on ALC branch 1 Setting up the M1XSP and the M1 to communicate with OnQ ALC 1 Install the ELK M1XSP per the instructions on page 3 Be sure...

Страница 13: ...4 F15 F16 G01 G02 G03 G04 G05 G06 G07 G08 G09 G10 G11 G12 G13 G14 G15 G16 H01 H02 H03 H04 H05 H06 H07 H08 H09 H10 H11 H12 H13 H14 H15 H16 ELK Light Device 129 130 131 132 133 134 135 136 137 138 139 1...

Страница 14: ...individual addresses program M1 Lighting devices 1 192 as Format Serial Expander Type Dimmer or On Off Switch if the device isn t dimmable For UPB link addresses program M1 Lighting devices 193 256 a...

Страница 15: ...1 192 PLC X 10 Ref I01 I02 I03 I04 I05 I06 I07 I08 I09 I10 I11 I12 I13 I14 I15 I16 J01 J02 J03 J04 J05 J06 J07 J08 J09 J10 J11 J12 J13 J14 J15 J16 K01 K02 K03 K04 K05 K06 K07 K08 K09 K10 K11 K12 K13 K...

Страница 16: ...pander Type On Off Switch Load Status and or Limitations with Elegance and LiteJet The wallplate button press feature with LiteJet Elegance is not directly usable with M1 However by assigning a button...

Страница 17: ...172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 PLC X 10 Ref I01 I02 I03 I04 I05 I06 I07 I08 I09 I10 I11 I12 I13 I14 I15 I16 J01 J02 J03 J04 J05 J06 J07 J08 J09 J10...

Страница 18: ...nd 17 All On All Off respectively Program the name for light device 16 as All On Off Set the Format to Serial Expander and Type to On Off Switch Activating M1 lighting 16 On it will send Phantom 16 Ac...

Страница 19: ...2 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 PLC X 10 Ref I01 I02 I03 I04 I05 I06 I07 I08 I09 I10 I11 I12 I13 I14 I15 I16 J...

Страница 20: ...nked learned into the M1XSP starting at the first M1 Lighting device 001 A1 Using just the M1XSP there is no way to have devices start at a specific location INSTEON devices cannot be removed or re ar...

Страница 21: ...e Right arrow key to access Menu 1 View Control Automation Fncts Press 2 followed by the right arrow key for the Lighting sub menu Advance to M1 Light 256 INSTEON LinkMode by entering 2 5 6 2 Turn ON...

Страница 22: ...s an option to eliminate Groups and free up addresses 193 M1 to 254 P14 See note N2 below N1 With the M1XSP Jumper S5 0 factory setting the M1XSP supports a total of 192 individual INSTEON or X 10 Lig...

Страница 23: ...H14 H15 H16 ELK Light Device 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 17...

Страница 24: ...s c RS 232 Setup this may show up as HAI SETUP in some older remotes For helpful information about the ViziaRF configuration use the following link to the Leviton web site http www leviton com OA_HTML...

Страница 25: ...be set as Backup B Optional Program a name to describe the location that this telephone number is reporting to C Do not program any numbers into the NUMBER TO DIAL location D Program the reporting for...

Страница 26: ...ignals onto the AC powerline if equipped with a PSC05 PLC interface Please note that M1 rules can only be activated by ON or OFF commands from these devices There is no rule activation support for DIM...

Страница 27: ...the AES Radio to be positioned far from the control 6 Construct a Serial Connection Cable from the M1XSP to the AES Radio Unit using the diagram below This cable requires a DB9F 9 Pin Female connecto...

Страница 28: ...ING ELKRP SOFTWARE MAKE SURE TO SEND ALL OF THIS PROGRAMMING TO THE CONTROL 10 Test Test Test It is very important to test each of the reported events SUPERVISION The M1XSP is enrolled with M1 Control...

Страница 29: ...esignated A and A1 Do the same for the data B White wire At the control splice the A1 and B1 wires to the A and B wires going to the next device Terminate the last wired device and the control JP3 ONL...

Страница 30: ...keys to exit Installer Programming 1234567890123456789012345 1234567890123456789012345 1234567890123456789012345 1234567890123456789012345 1234567890123456789012345 1234567890123456789012345 12345678...

Страница 31: ...M1XSP InstallationManual Page 31 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 32: ...engage a 120 Ohm resistor for terminating the M1 RS 485 Data Bus See M1 Data bus wiring instructions before use JP2 Used to engage a 120 Ohm resistor for terminating the Outbound External RS 485 Data...