ELK-M1XRF319 Installation Manual
Page 9
Wrist Panic Transmitter ‐
Part # RE103
> Notes:
none >
Enroll Process:
Press Main Button
> Options:
Set Opt1 & Opt2 to 0 (no) >
Loop
:
Set as 2
Driveway Motion Detector ‐
Part # RE104
> Notes:
none >
Enroll Process:
Press tamper switch
> Options:
Set Opt1 & Opt2 to 0 (no) >
Loop
:
Set as 2
Pencil Door And Window Transmitter ‐
Part # RE102
> Notes:
none >
Enroll Process:
Insert battery or press tamper switch
> Options:
Set Opt1 & Opt2 to 0 (no)
if using built‐in reed
OR
Set Opt1 & Opt2 to 1 (yes) if an external N/O switch is connected to the screw terminals.
> Loop:
Set as 2 if using built‐in reed
OR
Set as 1
if external N/O switch is connected to the screw terminals.
WE DO NO RECOMMEND USING BOTH REED AND EXT. SWITCH AT SAME TIME.
Four Button Keyfob Transmitter
‐ Part # RE100
> Notes:
none >
Enroll Process:
Press and hold Lock and Unlock Buttons (1&2) together at same time. >
Options:
Setting Opt1 to 1 (yes) will swap the 4 button assignments from 1 thru 4 to 5 thru 8. Opt2 should be left as 0 (no).
>
Loop
: N/A
Additional info:
Combo pressing
the Lock and Unlock buttons at same time will trigger the event assigned to Key 7. Pressing the Light and Asterisk together will trigger the event assigned to Key 8.
Door & Window Transmitter ‐
Part # RE101
> Notes:
none >
Enroll Process:
Insert battery or press tamper switch
> Options:
Set Opt1 to 0 (no) to use internal
reed switch. Set to 1 (yes) to disable internal reed switch and use external screw terminals instead. Set Opt2 to 0 (no) to configure ext. screw terminals for N/O
(open circuit) switch. Set to 1 (yes) to configure screw terminals for N/C (closed circuit) switch.
> Loop:
Set as 2 Add info: TXID ID on transmitter can represent
the internal reed or the external contacts (see Option 1) but not both at the same time. While not recommended, transmitter can be enrolled twice to use both
inputs as 2 different M1 zones. 1st zone will be internal reed – Set Loop as 2. 2
nd
zone will be external contacts – Set Loop as 1. TXID number of the second zone
must be manually edited to make it 1 digit greater. EG: If TXID of 1
st
zone is DL 106AA4, edit TXID of 2
nd
zone so that it is DL 106AA5.
Temperature Limit Detector ‐
Part # RE105
> Notes:
none >
Enroll Process:
Press tamper switch
> Options:
Set Opt1 & Opt2 to 0 (no) >
Loop
:
Set as 2
Tilt Sensor ‐
Part # RE106
> Notes:
none >
Enroll Process:
Press tamper switch
> Options:
Set Opt1 & Opt2 to 0 (no) >
Loop
:
Set as 2
PIR Motion Detector ‐
Part # RE110P
> Notes:
This transmitter does not send restorals. Control automatically assumes restoral ~8 seconds after violation. >
Enroll Process:
Remove back cover to activate tamper switch.
> Options:
Set Opt1 & Opt2 to 0 (no) >
Loop
:
Set as 2
Part Number, Description, Notes, Enroll Process, Options and Loop ID
Image
These transmitters, when used with an Elk M1 Control, can be enrolled from either Keypad Installer Programming (Menu 14. Sub‐Menu 3) via the
“Lrn” method, OR by entering the TXID through Elk’s RP Programming Software. Carefully follow the specific transmitter notes outlined below.
Resolution brand compatible 319.5MHz Transmitters
Smoke Detector ‐
Part # 60‐848‐02‐95, or equivalent
> Notes:
None >
Enroll Process:
For units with tamper supervision activate the tamper,
otherwise press the front Test button which will transmit a violation (alarm) >
Options:
Set Opt1 to 1 (yes) for units with tamper supervision.
Leave Opt2 as 0 (no). >
Loop
:
Set as 2
Single Button Wrist/Pendant Panic ‐
Part # 60‐906‐95, or equivalent
> Notes:
None >
Enroll Process:
Press and hold main button >
Options:
Set Opt1 & Opt2 to 0 (no) >
Loop
:
Set as 2
Single Button Pendant Panic ‐
Part # 60‐578‐10‐95, or equivalent
> Notes:
None >
Enroll Process:
Press and hold main button >
Options:
Set
Opt1 & Opt2 to 0 (no) >
Loop
:
Set as 2
PIR Motion Detector ‐
Part # 60‐880‐95, or equivalent
> Notes:
Transmitter does not send restores. Control automatically assumes restoral 8
seconds after violation >
Enroll Process:
Remove back cover to activate tamper switch >
Options:
Set Opt1 & Opt2 to 0 (no) >
Loop
:
Set as 2
Door & Window Transmitter
‐ Part #'s 60‐362‐10‐319.5, 60‐641‐95, or equiv.
> Notes:
Screw terminals allow external N/O switch to be used in
place of the built‐in reed. >
Enroll Process:
Remove back cover to activate tamper switch >
Options:
Set Opt1 & Opt2 to 0 (no) if using built‐in
reed
OR
Set Opt1 & Opt2 both to 1 (yes) to disable internal reed and use external N/O switch connected to screw terminals
> Loop:
Set as 2 if
using built‐in reed
OR
Set as 1 if external N/O switch is connected to the screw terminals.
DO NOT USE BOTH REED AND EXT. SWITCH AT SAME TIME.
PIR Motion Detector ‐
Part # 60‐703‐95, or equivalent
> Notes:
Transmitter does not send restores. Control automatically assumes restoral 8
seconds after violation >
Enroll Process:
Remove back cover to activate tamper switch >
Options:
Set Opt1 & Opt2 to 0 (no) >
Loop
:
Set as 2
PIR Motion Detector ‐
Part # 60‐511‐01‐95, or equivalent
> Notes:
Transmitter does not send restores. Control automatically assumes restoral 8
seconds after violation >
Enroll Process:
Remove back cover to activate tamper switch >
Options:
Set Opt1 & Opt2 to 0 (no) >
Loop
:
Set as 2
Door & Window Transmitter ‐
Part # 60‐499‐10‐319.5, or equivalent
> Notes:
Screw terminals allow external N/O switch to be used in place of
the built‐in reed. >
Enroll Process:
Press Test button or Tamper Switch >
Options:
Set Opt1 & Opt2 to 0 (no) if using built‐in reed
OR
Set Opt1 &
Opt2 both to 1 (yes) to disable internal reed and use external N/O switch connected to screw terminals
> Loop:
Set as 2 if using built‐in reed
OR
Set as 1 if external N/O switch is connected to the screw terminals.
DO NOT USE BOTH REED AND EXT. SWITCH AT SAME TIME
Door & Window Transmitter ‐
Part # 60‐688‐95, or equivalent
> Notes:
Screw terminals allow external N/O switch to be used in place of the
built‐in reed. >
Enroll Process:
Press Test button or Tamper Switch >
Options:
Set Opt1 & Opt2 to 0 (no) if using built‐in reed
OR
Set Opt1 & Opt2
both to 1 (yes) to disable internal reed and use external N/O switch connected to screw terminals
> Loop:
Set as 2 if using built‐in reed
OR
Set as
1 if external N/O switch is connected to the screw terminals.
DO NOT USE BOTH REED AND EXT. SWITCH AT SAME TIME
Door & Window Transmitter ‐
Part # 60‐741‐95, or equivalent
> Notes:
none >
Enroll Process:
Insert Battery to power up >
Options:
Set Opt1 &
Opt2 to 0 (no)
> Loop:
Set as 2
Heat 'Rate Of Rise' Transmitter ‐
Part # 60‐460‐319.5, or equivalent
> Notes:
none >
Enroll Process:
Press Test Button located on circuit board
inside unit next to battery >
Options:
Set Opt1 & Opt2 to 0 (no)
> Loop:
Set as 2
Glass Break Transmitter ‐
Part # 60‐873‐95, 60‐834‐95, or equivalent
> Notes:
Opt2 must be set to 1 (yes) >
Enroll Process:
Activate tamper
switch >
Options:
Set Opt1 to 0 (no) and Opt2 to 1 (yes)
> Loop:
Set as 2
Shock Sensor ‐
Part # 60‐886‐95, or equivalent
> Notes:
Opt2 must be set to 1 (yes) >
Enroll Process:
Press Test button >
Options:
Set Opt1
to 0 (no) and Opt2 to 1 (yes)
> Loop:
Set as 2
Single Button Panic Transmitter ‐
Part # 60‐458‐10‐319.5, or equivalent
> Notes:
none >
Enroll Process:
Press main button >
Options:
Set
Opt1 to 0 (no) and Opt2 to 1 (yes)
> Loop:
Set as 2
Glass Guard Transmitter ‐
Part # 6046210319.5
> Notes:
none >
Enroll Process:
Press tamper switch >
Options:
Set Opt1 & Opt2 to 0 (no)
> Loop:
Set as 2
Freeze Sensor Transmitter ‐
Part # 60‐504‐10‐95R, or equivalent
> Notes:
none >
Enroll Process:
Press tamper switch >
Options:
Set Opt1 &
Opt2 to 0 (no)
> Loop:
Set as 2
Four Button Keyfob Transmitter ‐
Part # 60‐606‐319.5, or equivalent
> Notes:
none >
Enroll Process:
Press and hold the Lock and Unlock
Buttons (buttons 1 & 2) together at the same time. >
Options:
Setting Opt1 to 1 (yes) will swap the 4 button assignments from 1 thru 4 to 5 thru 8.
Opt2 should be left as 0 (no).
>
Loop
: N/A
Additional info:
Combo pressing the Lock and Unlock buttons at same time will trigger the event
assigned to Key 7. Pressing the Light and Asterisk together will trigger the event assigned to Key 8.
Carbon Monoxide Sensor ‐
Part # 600‐6520‐95
> Notes:
none >
Enroll Process:
TXID ID number printed on sensor label must be entered
manually into the M1 Wireless Zone (Wzone) TXID programming field. This sensor cannot be learned in by the transmission trip or tamper
methods. >
Options:
Set Opt1 & Opt2 to 0 (no)
> Loop:
Set as 0
ElkRP programming of M1
– Set Zone Def as 17 = Carbon Monoxide and set
Zone Type as 0 = EOL/Wireless. In the Wireless Setup set the Enabled box and set Supervision to 3 = Fire Supervision.
Part Number, Description, Notes, Enroll Process, Options and Loop ID
Image
These alternate brand transmitters, when used with an Elk M1 Control, can be enrolled from either Keypad Installer Programming (Menu 14. Sub‐Menu 3) via the
“Lrn” method, OR by entering the TXID through Elk’s RP Programming Software. Carefully follow the specific transmitter notes outlined below.
Elk makes no guarantee of compatibility for any transmitter model not listed. Elk shall not be responsible if a manufacturer changes or discontinues any listed model.