background image

ELK-M1XRF319  Installation Manual 

Page 9

Wrist Panic Transmitter ‐ 

Part # RE103   

> Notes:

 none   > 

Enroll Process:

 Press Main Button    

> Options: 

Set Opt1 & Opt2 to 0 (no)  > 

Loop

:

 

Set as 2

Driveway Motion Detector ‐ 

Part # RE104   

> Notes:

 none   > 

Enroll Process:

 Press tamper switch    

> Options: 

Set Opt1 & Opt2 to 0 (no)  > 

Loop

:

 

Set as 2

Pencil Door And Window Transmitter ‐ 

Part # RE102   

> Notes:

 none   > 

Enroll Process:

 Insert battery or press tamper switch  

> Options:

 Set Opt1 & Opt2 to 0 (no) 

if using built‐in reed  

OR

  Set Opt1 & Opt2 to 1 (yes) if an external N/O switch is connected to the screw terminals.  

> Loop: 

Set as 2 if using built‐in reed 

OR

  Set as 1 

if external N/O switch is connected to the screw terminals.  

WE DO NO RECOMMEND USING BOTH REED AND EXT. SWITCH AT SAME TIME.

Four Button Keyfob Transmitter 

‐ Part # RE100   

> Notes:

 none   > 

Enroll Process:

 Press and hold Lock and Unlock Buttons (1&2) together at same time.  > 

Options: 

Setting Opt1 to 1 (yes) will swap the 4 button assignments from 1 thru 4 to 5 thru 8.   Opt2 should be left as 0 (no).  

Loop

: N/A

   

Additional info: 

Combo pressing 

the Lock and Unlock buttons at same time will trigger the event assigned to Key 7. Pressing the Light and Asterisk together will trigger the event assigned to Key 8.

Door & Window Transmitter ‐

 Part # RE101   

> Notes:

 none   > 

Enroll Process:

 Insert battery or press tamper switch  

> Options:

 Set Opt1 to 0 (no) to use internal 

reed switch.  Set to 1 (yes) to disable internal reed switch and use external screw terminals instead.  Set Opt2 to 0 (no) to configure ext. screw terminals for N/O 

(open circuit) switch.  Set to 1 (yes) to configure screw terminals for N/C (closed circuit) switch.  

> Loop: 

Set as 2   Add info:  TXID ID on transmitter can represent  

the internal reed or the external contacts (see Option 1) but not both at the same time.  While not recommended, transmitter can be enrolled twice to use both 

inputs as 2 different M1 zones.  1st zone will be internal reed – Set Loop as 2.  2

nd

 zone will be external contacts – Set Loop as 1.  TXID number of the second zone 

must be manually edited to make it 1 digit greater.  EG:  If TXID of 1

st

 zone is DL 106AA4,  edit TXID of 2

nd

 zone so that it is DL 106AA5.

Temperature Limit Detector ‐ 

Part # RE105   

> Notes:

 none   > 

Enroll Process:

 Press tamper switch    

> Options: 

Set Opt1 & Opt2 to 0 (no)  > 

Loop

:

 

Set as 2

Tilt Sensor ‐ 

Part # RE106    

> Notes:

 none   > 

Enroll Process:

 Press tamper switch    

> Options: 

Set Opt1 & Opt2 to 0 (no)  > 

Loop

:

 

Set as 2

PIR Motion Detector ‐ 

Part # RE110P   

> Notes:

 This transmitter does not send restorals.  Control automatically assumes restoral ~8 seconds after violation.   > 

Enroll Process:

 Remove back cover to activate tamper switch.  

> Options: 

Set Opt1 & Opt2 to 0 (no)  > 

Loop

:

 

Set as 2

 

     

Part Number, Description, Notes, Enroll Process, Options and Loop ID 

Image

These transmitters, when used with an Elk M1 Control, can be enrolled from either Keypad Installer Programming (Menu 14. Sub‐Menu 3) via the 

“Lrn” method, OR by entering the TXID through Elk’s RP Programming Software.  Carefully follow the specific transmitter notes outlined below.

Resolution brand compatible 319.5MHz Transmitters

Smoke Detector ‐ 

Part #  60‐848‐02‐95, or equivalent   

 > Notes:

 None    > 

Enroll Process:

 For units with tamper supervision activate the tamper, 

otherwise press the front Test button which will transmit a violation (alarm)  > 

Options: 

Set Opt1 to 1 (yes) for units with tamper supervision.  

Leave Opt2 as 0 (no).   > 

Loop

:

 

Set as 2

Single Button Wrist/Pendant Panic ‐ 

Part #  60‐906‐95, or equivalent   

> Notes:

 None    > 

Enroll Process:

 Press and hold main button  > 

Options: 

Set Opt1 & Opt2 to 0 (no)   > 

Loop

:

 

Set as 2

Single Button Pendant Panic ‐ 

Part #  60‐578‐10‐95, or equivalent   

> Notes:

 None    > 

Enroll Process:

 Press and hold main button  > 

Options: 

Set 

Opt1 & Opt2 to 0 (no)   > 

Loop

:

 

Set as 2

PIR Motion Detector ‐ 

Part #  60‐880‐95, or equivalent  

> Notes:

 Transmitter does not send restores.  Control automatically assumes restoral 8 

seconds after violation   > 

Enroll Process:

 Remove back cover to activate tamper switch  > 

Options: 

Set Opt1 & Opt2 to 0 (no)   > 

Loop

:

 

Set as 2

Door & Window Transmitter 

‐ Part #'s 60‐362‐10‐319.5, 60‐641‐95, or equiv.   

> Notes:

  Screw terminals allow external N/O switch to be used in 

place of the built‐in reed.  > 

Enroll Process:

 Remove back cover to activate tamper switch  > 

Options: 

Set Opt1 & Opt2 to 0 (no) if using built‐in 

reed 

OR

 Set Opt1 & Opt2 both to 1 (yes) to disable internal reed and use external N/O switch connected to screw terminals   

> Loop: 

Set as 2 if 

using built‐in reed 

OR

  Set as 1 if external N/O switch is connected to the screw terminals.  

DO NOT USE BOTH REED AND EXT. SWITCH AT SAME TIME.

PIR Motion Detector ‐ 

Part #  60‐703‐95, or equivalent   

> Notes:

 Transmitter does not send restores.  Control automatically assumes restoral 8 

seconds after violation   > 

Enroll Process:

 Remove back cover to activate tamper switch  > 

Options: 

Set Opt1 & Opt2 to 0 (no)   > 

Loop

:

 

Set as 2

PIR Motion Detector ‐ 

Part #  60‐511‐01‐95, or equivalent  

> Notes:

 Transmitter does not send restores.  Control automatically assumes restoral 8 

seconds after violation   > 

Enroll Process:

 Remove back cover to activate tamper switch  > 

Options: 

Set Opt1 & Opt2 to 0 (no)   > 

Loop

:

 

Set as 2

Door & Window Transmitter ‐ 

Part # 60‐499‐10‐319.5, or equivalent    

> Notes:

  Screw terminals allow external N/O switch to be used in place of 

the built‐in reed.  > 

Enroll Process:

 Press Test button or Tamper Switch  > 

Options: 

Set Opt1 & Opt2 to 0 (no) if using built‐in reed 

OR

 Set Opt1 & 

Opt2 both to 1 (yes) to disable internal reed and use external N/O switch connected to screw terminals   

> Loop: 

Set as 2 if using built‐in reed 

OR

  

Set as 1 if external N/O switch is connected to the screw terminals.  

DO NOT USE BOTH REED AND EXT. SWITCH AT SAME TIME

Door & Window Transmitter ‐ 

Part #  60‐688‐95, or equivalent   

> Notes:

  Screw terminals allow external N/O switch to be used in place of the 

built‐in reed.  > 

Enroll Process:

 Press Test button or Tamper Switch  > 

Options: 

Set Opt1 & Opt2 to 0 (no) if using built‐in reed 

OR

 Set Opt1 & Opt2 

both to 1 (yes) to disable internal reed and use external N/O switch connected to screw terminals   

> Loop: 

Set as 2 if using built‐in reed 

OR

  Set as 

1 if external N/O switch is connected to the screw terminals.  

DO NOT USE BOTH REED AND EXT. SWITCH AT SAME TIME

Door & Window Transmitter ‐ 

Part #  60‐741‐95, or equivalent   

> Notes:

  none  > 

Enroll Process:

 Insert Battery to power up  > 

Options: 

Set Opt1 & 

Opt2 to 0 (no)  

> Loop: 

Set as 2 

Heat 'Rate Of Rise' Transmitter ‐ 

Part #  60‐460‐319.5, or equivalent   

> Notes:

  none    > 

Enroll Process:

 Press Test Button located on circuit board 

inside unit next to battery   > 

Options: 

Set Opt1 & Opt2 to 0 (no)  

> Loop: 

Set as 2

Glass Break Transmitter ‐ 

 Part #  60‐873‐95, 60‐834‐95, or equivalent   

> Notes:

  Opt2 must be set to 1 (yes)   > 

Enroll Process:

 Activate tamper 

switch   > 

Options: 

Set Opt1 to 0 (no) and Opt2 to 1 (yes)  

> Loop: 

Set as 2

Shock Sensor ‐ 

Part #  60‐886‐95, or equivalent     

> Notes:

  Opt2 must be set to 1 (yes)    > 

Enroll Process:

 Press Test button   > 

Options: 

Set Opt1 

to 0 (no) and Opt2 to 1 (yes)   

> Loop: 

Set as 2

Single Button Panic Transmitter ‐ 

Part #  60‐458‐10‐319.5, or equivalent   

> Notes:

  none   > 

Enroll Process:

 Press main button   > 

Options: 

Set 

Opt1 to 0 (no) and Opt2 to 1 (yes)  

> Loop: 

Set as 2

Glass Guard Transmitter ‐ 

Part #  6046210319.5     

> Notes:

  none     > 

Enroll Process:

 Press tamper switch     > 

Options: 

Set Opt1 & Opt2 to 0 (no)  

> Loop: 

Set as 2

Freeze Sensor Transmitter ‐ 

Part #  60‐504‐10‐95R, or equivalent    

> Notes:

  none     > 

Enroll Process:

 Press tamper switch     > 

Options: 

Set Opt1 & 

Opt2 to 0 (no)  

> Loop: 

Set as 2

Four Button Keyfob Transmitter ‐ 

Part #  60‐606‐319.5, or equivalent    

> Notes:

  none     > 

Enroll Process:

 Press and hold the Lock and Unlock 

Buttons (buttons 1 & 2) together at the same time.  > 

Options: 

Setting Opt1 to 1 (yes) will swap the 4 button assignments from 1 thru 4 to 5 thru 8.   

Opt2 should be left as 0 (no).  

Loop

: N/A

   

Additional info: 

Combo pressing the Lock and Unlock buttons at same time will trigger the event 

assigned to Key 7. Pressing the Light and Asterisk together will trigger the event assigned to Key 8.

Carbon Monoxide Sensor ‐ 

 Part # 600‐6520‐95    

> Notes:

  none     > 

Enroll Process:

 TXID ID number printed on sensor label must be entered 

manually into the M1 Wireless Zone (Wzone) TXID programming field.  This sensor cannot be learned in by the transmission trip or tamper 

methods.    > 

Options: 

Set Opt1 & Opt2 to 0 (no)  

> Loop: 

Set as 0    

ElkRP programming of M1

 – Set Zone Def as 17 = Carbon Monoxide and set 

Zone Type as 0 = EOL/Wireless.  In the Wireless Setup set the Enabled box and set Supervision to 3 = Fire Supervision.  

Part Number, Description, Notes, Enroll Process, Options and Loop ID 

 

Image

These alternate brand transmitters, when used with an Elk M1 Control, can be enrolled from either Keypad Installer Programming (Menu 14. Sub‐Menu 3) via the 

“Lrn” method, OR by entering the TXID through Elk’s RP Programming Software.  Carefully follow the specific transmitter notes outlined below.

Elk makes no guarantee of compatibility for any transmitter model not listed.  Elk shall not be responsible if a manufacturer changes or discontinues any listed model.

Содержание ELK-M1XRF319

Страница 1: ...found inside INSTALLATION MANUAL L682 Rev B 8 11 20 IMPORTANT NOTE Please consult the Elk M1 Dealer website for downloads of the latest M1 Control firmware and ElkRP Software For compatibility with t...

Страница 2: ...using an indoor antenna have a quality outdoor antenna installed Reorient the receiving antenna until interference is induced or eliminated Move the receiver away from the security control Move the an...

Страница 3: ...is compatible with that same frequency and protocol A mixture of receivers and transmitters on the same installation is possible as long as each transmitter is installed within range of the receiver w...

Страница 4: ...must be set as Address 2 so the first wireless transmitter can be zone 017 This is because M1 only allows wireless zones to reside from Zone 017 to 160 When using ElkRP Programming Software all zones...

Страница 5: ...er Valid Pin 01 Bus Module Enrollment Examples of Data Bus Address Settings Conflicts can exist if a group of hardwired zones are allowed to overlap or intrude where wireless sensors zones exist Wirel...

Страница 6: ...seful to the receiver in providing a relative signal strength as a reference of the acceptable reliability of the sensor and it s mounting orientation and or location When the Receiver hears a wireles...

Страница 7: ...tery is good Following an alarm the zone will remain violated Police Trouble until transmitter sends hourly check in OR until User manually resets zone by pressing and holding the button a second time...

Страница 8: ...not send restores Control automatically assumes restoral 8 seconds after violation Enroll Process Remove back cover to activate tamper switch Options Set Opt1 Opt2 to 0 no Loop Set as 2 PIR Motion De...

Страница 9: ...rminals DO NOT USE BOTH REED AND EXT SWITCH AT SAME TIME PIR Motion Detector Part 60 703 95 or equivalent Notes Transmitter does not send restores Control automatically assumes restoral 8 seconds afte...

Страница 10: ...r selections R02 and R03 for supervision time values Valid values are 0 1 or 3 Factory default setting is 1 Normal Supervision Option for certain types of Transmitters See list of compatible Transmitt...

Страница 11: ...event Key 2 Evt 0000 r name of event Key 3 Evt 0000 r name of event Key 4 Evt 0000 r name of event Key 5 Evt 0000 r name of event Key 6 Evt 0000r name of event Key 7 Evt 0000 r name of event Key 8 Evt...

Страница 12: ...or RRF H or RRF H or RRF Data Bus Addr 2 Zn 17 32 Data Bus Addr 3 Zn 33 48 Starting Zn ID 49 Data Bus Addr 4 Zn 49 64 M1XRF Cells marked indicate a Reserved Address which can only be used for wireless...

Страница 13: ...Addr 11 Zn 161 176 M1XRF Data Bus Addr 2 Zn 17 32 Data Bus Addr 3 Zn 33 48 Data Bus Addr 4 Zn 49 64 Data Bus Addr 5 Zn 65 80 Data Bus Addr 6 Zn 81 96 Data Bus Addr 7 Zn 97 112 Data Bus Addr 8 Zn 113 1...

Страница 14: ...97 112 Zones 113 128 Zones 129 144 Zones 145 160 Zones 161 176 Zones 177 192 Zones 193 208 Bus Addr x Bus Addr 2 Bus Addr 3 Bus Addr 4 Bus Addr 5 Bus Addr 6 Bus Addr 7 Bus Addr 8 Bus Addr 9 Bus Addr 1...

Страница 15: ...in center is assigned as Address 2 The additional Receivers are Addresses 3 and 4 In theory it is possible to install up to 9 total Wireless Receivers on a single M1 Control provided none of those ad...

Страница 16: ...Page 16 ELK M1XRF319 Installation Manual PO Box 100 3266 US Hwy 70 West Hildebran NC 28637 828 397 4200 828 397 4415 Fax http www elkproducts com...

Отзывы: