OVERVIEW

 

The ELK-M1XRF319 Wireless Receiver allows wireless transmitters that operate on the 319.5MHz Frequency and that adhere to 

the Interlogix protocol to work with ELK-M1 Controls.  A list of compatible transmitters brands and models is published on page 7 of 

this manual.  The receiver connects to the M1's RS-485 four (4) wire data bus and integrates much the same as a hardwired zone 

expander.  It can be installed remotely from the control virtually anywhere inside the premises up to the maximum allowed distance 

of the data bus.  One receiver can cover an average size home and up to 144 wireless transmitters.  All transmitter programming 

and enrollment data is stored in the M1 Control and not in the receiver(s).  This means that additional receivers, up to 9 total, may be 

connected for extremely large coverage areas and without needing to relearn transmitters.  

WARNING: Elk offers two other models of Wireless Receivers for the M1 Control.  Each Receiver operates on a different 

frequency.  It is critical that the frequency and protocol of each installed transmitter be matched with a receiver that is 

compatible with that same frequency and protocol.  A mixture of receivers and transmitters on the same installation is 

possible as long as each transmitter is installed within range of the receiver which matches its frequency and protocol.  

Receivers are physically and electronically different and can only receive the transmissions of their matching transmitters. 

Installation and Setup

MOUNT UNIT    *   CONNECT WIRING   *   SET ADDRESS   *   PERFORM BUS ENROLLMENT PROCESS

RS-485 4-WIRE Data Bus Connections

 

     + 12

 

        A     (Data)

 

        B     (Data)

 

     CMN  (- NEG)

Note: The last 2 screws are not used.  Do not 

connect any wires to terminals ZONE or RTN.

Address 

Indicators for Data Bus

IMPORTANT:  If this Receiver is the LAST device on the RS-485 Data Bus then connect a 120 Ohm Resistor (included in hard-

ware bag) across terminals A and B along with the wiring.  The last device on the data bus MUST include this bus termination.

Antenna 2

Antenna 1

Diagnostic 

Indicators (see page 6)

Backward button 

* Used during 

install and setup 

only

Forward button 

* Used during 

install and setup 

only

Enter button 

* Used during 

install and setup 

only

VERY IMPORTANT:

The lower LED labeled "FREQ" must 

be blinking 1 time (once) every three 

(3) seconds at all times.  

One blink indicates the Receiver is 

properly set for 319.5MHz Frequency 

and able to decode Elk319 

Transmitters  

See page 6.

STATUS (Programming) Indicator

Содержание ELK-M1XRF319

Страница 1: ...found inside INSTALLATION MANUAL L682 Rev B 8 11 20 IMPORTANT NOTE Please consult the Elk M1 Dealer website for downloads of the latest M1 Control firmware and ElkRP Software For compatibility with t...

Страница 2: ...using an indoor antenna have a quality outdoor antenna installed Reorient the receiving antenna until interference is induced or eliminated Move the receiver away from the security control Move the an...

Страница 3: ...is compatible with that same frequency and protocol A mixture of receivers and transmitters on the same installation is possible as long as each transmitter is installed within range of the receiver w...

Страница 4: ...must be set as Address 2 so the first wireless transmitter can be zone 017 This is because M1 only allows wireless zones to reside from Zone 017 to 160 When using ElkRP Programming Software all zones...

Страница 5: ...er Valid Pin 01 Bus Module Enrollment Examples of Data Bus Address Settings Conflicts can exist if a group of hardwired zones are allowed to overlap or intrude where wireless sensors zones exist Wirel...

Страница 6: ...seful to the receiver in providing a relative signal strength as a reference of the acceptable reliability of the sensor and it s mounting orientation and or location When the Receiver hears a wireles...

Страница 7: ...tery is good Following an alarm the zone will remain violated Police Trouble until transmitter sends hourly check in OR until User manually resets zone by pressing and holding the button a second time...

Страница 8: ...not send restores Control automatically assumes restoral 8 seconds after violation Enroll Process Remove back cover to activate tamper switch Options Set Opt1 Opt2 to 0 no Loop Set as 2 PIR Motion De...

Страница 9: ...rminals DO NOT USE BOTH REED AND EXT SWITCH AT SAME TIME PIR Motion Detector Part 60 703 95 or equivalent Notes Transmitter does not send restores Control automatically assumes restoral 8 seconds afte...

Страница 10: ...r selections R02 and R03 for supervision time values Valid values are 0 1 or 3 Factory default setting is 1 Normal Supervision Option for certain types of Transmitters See list of compatible Transmitt...

Страница 11: ...event Key 2 Evt 0000 r name of event Key 3 Evt 0000 r name of event Key 4 Evt 0000 r name of event Key 5 Evt 0000 r name of event Key 6 Evt 0000r name of event Key 7 Evt 0000 r name of event Key 8 Evt...

Страница 12: ...or RRF H or RRF H or RRF Data Bus Addr 2 Zn 17 32 Data Bus Addr 3 Zn 33 48 Starting Zn ID 49 Data Bus Addr 4 Zn 49 64 M1XRF Cells marked indicate a Reserved Address which can only be used for wireless...

Страница 13: ...Addr 11 Zn 161 176 M1XRF Data Bus Addr 2 Zn 17 32 Data Bus Addr 3 Zn 33 48 Data Bus Addr 4 Zn 49 64 Data Bus Addr 5 Zn 65 80 Data Bus Addr 6 Zn 81 96 Data Bus Addr 7 Zn 97 112 Data Bus Addr 8 Zn 113 1...

Страница 14: ...97 112 Zones 113 128 Zones 129 144 Zones 145 160 Zones 161 176 Zones 177 192 Zones 193 208 Bus Addr x Bus Addr 2 Bus Addr 3 Bus Addr 4 Bus Addr 5 Bus Addr 6 Bus Addr 7 Bus Addr 8 Bus Addr 9 Bus Addr 1...

Страница 15: ...in center is assigned as Address 2 The additional Receivers are Addresses 3 and 4 In theory it is possible to install up to 9 total Wireless Receivers on a single M1 Control provided none of those ad...

Страница 16: ...Page 16 ELK M1XRF319 Installation Manual PO Box 100 3266 US Hwy 70 West Hildebran NC 28637 828 397 4200 828 397 4415 Fax http www elkproducts com...

Отзывы: