M1 Cross Platform Controllers - User Guide

Page 16

5-KEYPAD TEMPERATURE SENSORS  

Provides the ability to select and

view the temperature sensor inside a M1KP LCD keypad.  Note: M1KP2 LCD
keypads do not have an inside temperature sensor.  If you select a keypad
that happens to be an M1KP2 the display will read “Not Enabled”.  Press the
RIGHT arrow key to select this menu, then press the UP or DOWN arrow keys
to scroll through the list of available keypads.  To jump directly to a particular
keypad enter it’s two digit number. The current temperature at the keypad will
display.  Press the * key to exit.

6-THERMOSTATS  

If HVAC thermostats are connected their current tempera-

ture may be read from this menu.  Press the RIGHT arrow key to select this
menu, then press the UP or DOWN arrow keys to scroll through the list of
available thermostats.  To jump directly to a particular thermostat enter it’s two
digit number. The current temperature is displayed. Press the * key to exit.

NOTE: To reduce scroll time, the keypad only displays the entities:
Tasks, Lights, Outputs, Temperature Sensors, Keypads, and Thermo-
stats which are installed, programmed, and selected to “show” on the
keypad.  This is done by the installer and can be changed as new
equipment is added.   It is also possible to enter a 2 or 3 digit number
and jump to ANY entity, even those NOT selected to “show”.

Menu 2-Reset Smoke Detectors

This is used to reset latched smoke detectors following a Fire alarm trip.
When a Smoke Detector causes an alarm it’s output circuitry will latch ON to
provide a visual identification.  IMPORTANT: It will be necessary to reset the
smoke detector circuitry following an alarm in order for any subsequent Fire
alarms to be detected.

1. Press the ELK key.  Enter a user code if prompted.
2. Use the UP or DOWN arrow keys to find “2-Reset Smoke Detectors”.
3. Press the RIGHT arrow key to select this menu.
4. The keypad will display “5 Seconds Smoke Output Reset”.
5. Two beeps from the keypad indicates that the reset is complete.

The keypad will automatically return to the main display.

Содержание Cross Platform Control ELK-M1KP

Страница 1: ...USER GUIDE Cross Platform Control This Guide covers the operation of the M1 and M1EZ8 Controller models TM L519 Rev G 05 07...

Страница 2: ...FOLLOWING The level of security obtained is directly related to two major factors 1 The quantity quality and placement of sensors attached to this system 2 The knowledge and operating skills that you...

Страница 3: ...he System 11 Alarm Acknowledgments 12 Troubles 12 Chime Mode Turning On and Off 13 Keypad Menus 14 Menu 1 View Control Automation Functions 14 Menu 2 Reset Smoke Detectors 16 Menu 3 Walk Test Area zon...

Страница 4: ...ll be heard when certain zone s are opened If OFF the chime mode is off Bypass Key Will be lighted anytime one or more zones have been excluded or bypassed If OFF no zones are bypassed Key This key se...

Страница 5: ...dible police holdup alarm and notifies a central monitoring center if monitoring has been purchased It is generally programmed as double press or press and hold for 2 seconds Medical If enabled this k...

Страница 6: ...______ Burglary Alarm Audible Cutoff Timer in minutes _______ Fire Alarm Audible Cutoff Timer in minutes _______ User Code Digits 4 digits ____ or 6 digits ____ F1 Key Function _______________________...

Страница 7: ...y name and number If a zone is programmed as bypassable you may bypass it permanently exclude it for the immediate arming cycle by pressing the Bypass key zone number the Bypass key again The display...

Страница 8: ...ming in the Vacation Mode Vacation mode is a second level of Away mode It can be used to activate energy saving automation features when the building will not be occupied for an extended period of tim...

Страница 9: ...tional If this feature was enabled by your installer it will allow arming in either the Away or Stay modes without having to enter your user code For security reasons however a user code is always req...

Страница 10: ...ess the Bypass key again 4 The Bypass light will light up if the bypass is accepted However if the zone is non bypassable an error tone will be heard Quick Bypassing of Violated Zones Optional The Qui...

Страница 11: ...larm 1 Proceed directly to the keypad 2 The display will show the alarm type and first zone that tripped 3 Enter your user code 4 The entry delay tone should stop 5 When the Armed light turns off the...

Страница 12: ...are many different types of trouble conditions that can be annunciated by the system including the following Trouble Conditions AC Power Failure Low Backup Battery Telephone Line Fault Fire Alarm Trou...

Страница 13: ...ime Tone or off When the Chime mode is On the Chime key will be lighted To turn the Chime mode Off 1 Press the Chime key one time If the Chime mode is off the Chime key will be dark not lighted To tur...

Страница 14: ...he first of 6 sub menus 1 TASKS will be displayed Each press of the UP arrow key will scroll through the other sub menus 4 When the desired menu displays press the RIGHT arrow to select 1 TASKS Tasks...

Страница 15: ...control individual outputs An output may be a relay used to signal or switch a device On or Off Outputs are not necessarily a physical form Outputs must first be assigned and programmed by the instal...

Страница 16: ...rature is displayed Press the key to exit NOTE To reduce scroll time the keypad only displays the entities Tasks Lights Outputs Temperature Sensors Keypads and Thermo stats which are installed program...

Страница 17: ...splay 6 Continue walk testing until each zone is tested as indicated by the top left hand number being the same as the number to it s right 7 When finished press the key to exit back to the main displ...

Страница 18: ...to a specific user 5 The keypad will display 001 Sel Chg name of User 6 To change the code press the RIGHT arrow and enter the new code digits Codes are either 4 or 6 digits in length depending on how...

Страница 19: ...enu 8 System Settings Requires a Master Level User Code With the exception of Set Sys Clock this menu is primarily used by a service technician It has 8 sub menus 81 SET SYS CLOCK 24 hr format Enter a...

Страница 20: ...ATION 85 CONNECT RP REMOTE PROGRAM Do Not Use except under guidance of the installation company There are two options Option 1 Pickup on Existing Call The system picks up the phone line and take over...

Страница 21: ...med number of rings the control should answer with four short beeps If an answering machine picks up wait for the message to quit and proceed as follows 2 Press to alert the control The control will a...

Страница 22: ...If the dialer is in use such as during an alarm message report then no dialtone will be heard and the offhook sequence will be ignored The best thing to do at that point is to try again a later when t...

Страница 23: ...instructions on resetting Smoke Detectors Acknowledge Reset an Alarm After a fire alarm is silenced the display will continue to show Fire Alarm until the detectors are reset and the alarm has been ac...

Страница 24: ...ish a meeting place outside where your family is to report Once you have evacuated the house do not return to a burning house 7 Advise the local fire authority that you have installed a fire alarm sys...

Страница 25: ...crew securing the transformer to the wall 2 The keypad will display AC Trouble after a programmed time delay 3 Activate the system using steps 1 to 7 listed above NOTE Plug the AC transformer into the...

Страница 26: ...e no user serviceable components in this product All necessary repairs must be made by the manufacturer Other repair methods may invalidate the FCC registration on this product This equipment cannot b...

Страница 27: ...g Station Location where alarm reports are transmitted Chime An audible alert used to indicate when a zone is violated The alert can be a tone voice or both Zones are selectable Duress Code A special...

Страница 28: ...www elkproducts com Printed in USA...

Отзывы: