1. Introduction: 

• The keypad can control, supervise and monitor up to four Roboguards and 
two Roboguard remote buttons with individual intruder detected, tamper and 
supervision LED’s and optional audible warning sounds from the speaker 
output.  
• The keypad has six highly configurable output switches to connect to other 
devices/systems. 
• The keypad functions off an external 12V power supply and a Roboguard 
receiver.  
• The keypad can also be used to monitor other devices via a 4 zone 
Roboguard Universal Transmitter (electric fence, burglar alarm, conventional 
wired sensor). 

 

2. Installation Procedure                                  

The installation comprises of: mounting, wiring, programming guards and 
remotes, and output switch programming. 
 

Step 1 (Mounting) :

 Mount the keypad close to the alarm panel or next to the 

alarm systems keypad (depending on whether you want control the 
Roboguards via the keypad or through the alarm system), and  the receiver in 
a ”high site” that will maximise the radio coverage for the installation area.  

 
 
 
Step 2 (Wiring):

 Wire the 12V power to the receiver and the keypad and 

check that the devices power up. Then connect the receiver data line to the 
keypad and wire the keypad outputs into the alarm panel zones (the switch 
wiring is dependent upon decisions that are made regarding the operation of 
the keypad, see step 4). Optionally you may choose to wire-in the speaker or 
an external horn. 

 
Step 3 (Programming): 

 Program in the identities of the 

guards/remotes/universal transmitters to the keypad. (See Ch 3). 

 
Step 4 (Switch Programming): 

Program the keypad to operate the output 

switches in the desired manner using the output switch programming mode. 
(See Ch 5). 

 

3. Programming Guards

 

and Remotes 

 

There are three programming modes 

Roboguard,

 

Remote and

 

Output Switch programming 

modes.

 In all programming modes tamper button is 

assigned “Enter” and trouble button is assigned 

“Delete” except when selecting N/C-N/O  

 

3.1 Roboguard Programming 
Step 1:

 To enter Roboguard programming mode: hold down the

 

tamper

 

button until a beep is heard and the red tamper LED is solid (ON) to indicate 
you are now in Roboguard programming mode (let go of the button now).  
Zone LED's which already have Roboguards programmed into them will now 
be solid (ON). 

Step 2:  

Press and release the button for the desired zone to be programmed 

(only the desired zone LED and the tamper LED should be ON). 

Step 3.

  Depress and release the tamper lever on the Roboguard (see diagram 

of parts in the Roboguard manual) to send a tamper signal to the keypad.  (Or 
for a Universal TX the tamper signal from the appropriate zone input) 

Step 4.

  The keypad will extinguish all the LED’s momentarily, and then enter 

the ‘start-up’ routine, i.e. 10 beeps will sound and all the LED’s will flash.  

 
Step 5.  

  Press any zone button to reset, the appropriate zone light should be 

on and can now be tested by triggering the Roboguard. 
 
To 

erase

 a Roboguard follow step 1, 2 and 4 but for step 3: press and release 

trouble.  

 

3.2 Remote TX Programming 
Step 1

 : To enter hold down the tamper and trouble button together until a 

beep is heard , both the red tamper and trouble LED 's should be solid(ON) to 
indicate you have entered Remote programming mode (let go of both buttons 
now).  

Step 2

 : Select either zone one (to learn an Arm/Disarm remote button) or 

zone two (to learn a panic button) ; now transmit using the Remote TX button 
of your choice corresponding to the function you wish to assign to that button, 
or Universal TX input channel of choice, and follow steps 3 and 4 as in 3.1 to 
complete.  

 

To 

erase

 a remote TX, enter Roboguard remote programming mode as above, 

select the function (zone 1 = Arm/Disarm, zone 2 = panic) you wish to erase 
then press and release the trouble button. 
 

NOTE: These programming modes are separate and you cannot program 
a remote control as a guard or visa versa. 
 

4. Keypad output switch programming

  

 

 

 

 

 

 

 

4.1 Output switch operation chart 

Numbers in table above indicate the output switch no. (In the columns under the four 
zones) that will pulse on the event (listed on the left). Multiple switches are triggered for 
redundancy in the zone 1 option. The installer should program the switch operation of the 
keypad depending on the available zones on the alarm panel and the functionality 
required. 
 

4.2 Programming Sequence 

To enter keypad output switch programming mode, disconnect the power of 
the keypad.  Hold down the tamper and trouble buttons and simultaneously re-
power the keypad.  The red tamper and trouble LED's will now both be 
flashing, you are now in keypad output switch programming mode.  Select 
your desired output switch configuration from the output switch operation 
chart (following) by pressing the desired zone (green light on).  Press 

Tamper Button

 once to register an 

N/O

 selection and 

Trouble

 to register 

an 

N/C

 selection. All LED’s will flash and the unit will beep 10 times. 

 

4.3 Output Switch Wiring: 

The keypad output switches use open collector low-side transistor drivers 
rated at a maximum of 500mA which is sufficient to switch a relay, timer 
board or alarm panel. The output voltage is normally held at 0V and will 
switch open circuit or to an externally connected voltage for 1 second when 
triggered. In some literature this is referred to as “normally closed”.  To 
trigger alarm panels you should connect an external 1k ohm (typically) 
resistor from the port output to the required voltage. Ensure that the 0V 
connections are common between the alarm panel and the keypad. 

 

NOTE: DO NOT WIRE ANY POWER ONTO THE  

OUTPUT SWITCH PINS. 

There are four different options that the keypad can 

be programmed to switch other devices. These 

options map an event to the output switches 

triggered and are described in the table below. 

 

ZONE LED.1 

ZONE 
LED.2 

ZONE LED.3 

ZONE 
LED.4 

 

 

 

 

 

Intruder 1 

1,5,6 

Intruder 2 

1,5,6 

Intruder 3 

1,5,6 

Intruder 4 

1,5,6 

Tamper 

1,5,6 

 

Trouble 

 

Remote Panic 

 

Arm/Disarm 

 