5. General Operation
The keypad is used to supervise and control Roboguards and to report activity
audibly, visually and electronically. The keypad monitors and supervises up to
four Roboguards. If an intruder is detected the speaker will beep the number
of the zone i.e. zone one, one beep, zone three, three beeps etc; the
corresponding LED will flash and the selected output switch will activate.
The keypad will respond to the remotes in all modes of operation.
5.1 GREEN Zone LED
(zone control and intruder detection)
Each of the keypad zones can be individually switched on or off. Switching
the zone off does NOT disable the supervision or the tamper monitoring. If the
green led for the zone is OFF then the zone is disabled. If it is ON then the
zone is ON and not triggered. If it is FLASHING then the zone is ON and has
been triggered. Pushing the zone button will change the state of the led from
OFF to ON and back again or from FLASHING to OFF to ON. NOTE: Zones
which do not have Roboguards programmed in will not function.
5.2 RED Tamper LED FLASHING
(Tamper Detection Triggered)
If a Roboguard is tampered with, a tamper detected signal will automatically
be sent to the keypad, it will sound the speaker 10 times, permanently flash
the red tamper LED and activate one of the output switches. To establish
which Roboguard was tampered with and to reset the tamper detect LED you
must do the following:
1.
Press and release the tamper button (tamper LED on, keypad is now in
tamper detected display mode)
2.
The zone LED for the Roboguard that has been tampered with will be solid
(on).
3.
Press and release all solid (on) LED's so only the red tamper LED is left
on.
4.
Press and release the tamper button (LED off) or do nothing as the keypad
will time out and exit automatically.
5.
You are back in the main display page.
NOTE : The Tamper indication will only be sent once per zone unless the
tamper indication is reset.
5.3 RED Trouble LED FLASHING
(Automatic battery and radio strength test)
The trouble (auto-test) routine is very important. The Roboguard sends an
‘auto-test’ radio signal to the keypad every 20 minutes. Should a guard fail to
report in, the keypad will indicate this by flashing the red ‘trouble’ LED and
activate an output switch. To establish which Roboguard is reporting the
trouble condition and to reset the trouble detect LED you must do the
following.
NOTE: This alarm is indicative of potential communication problems
which may be due to bad radio reception or battery problems.
1.
Press and release the trouble button (trouble LED on, keypad is now in
trouble condition display mode)
2.
The zone LED for the Roboguard that is “in trouble” will be solid (on).
3.
Press and release all solid (on) LED's so only the red trouble LED is on.
4.
Press and release the trouble button (LED off) or do nothing as the keypad
will time out and exit automatically.
5.
You are back in the main display page.
Technical Details
Dimensions:
104 X 64 X 27
Weight:
100 g
Current Consumption:
+_ 25 mA
Required receiver
UHF 433.92 MHz
Required Power Supply
12V DC
Colour:
White
Packing Contents
keypad allen key
keypad manual
Trap International CC
PO BOX 38113
Point, 4069
Durban
South Africa
www.roboguard.co.za
Roboguard keypad is a wired/fixed 4 + 2 zone decoder
panel specifically designed to interface Roboguards and
remotes to other systems or function as a complete
system on its own.
Revision 1.1