The Quick Reference Card provides a quick overview of your spa’s  

main functions and the operations accessible with your digital control pad.

Key 1 

Press 

Key 1

 key to turn Pump 1 on at low speed. Press a 

second time to turn pump to high speed (with a dual-speed 

pump). A third time turns pump off.
A built-in timer automatically turns pump off after 20 minu-

tes, unless pump has been manually deactivated first.
 

The “Pump 1” indicator lights up when Pump 1 is on.  

 

With dual-speed pump, indicator will flash when  

 

Pump 1 is on at low speed.

Spa functions

k-19-in

series of k-19 keypads for in.xe spa systems

Key 2 

      (2 Pump System)

Press 

Key 2

 key to turn Pump 2 on at low speed. Press

a second time to turn pump to high speed. A third time

turns pump off. A built-in timer automatically turns pump 

off after a prede-termined period of time, unless it has been 

manually deactivated first.
 

The “Pump 2” indicator lights up when Pump 2 is on.  

 

The indicator will flash when Pump 2 is on at low speed.

Troubleshooting

Hr

An internal hardware error has been detected in in.xe. 

Contact dealer or service supplier.

HL 

The system has shut the heater down because the temperature at the 

heater has reached 119°F (48°C). Do not enter the water! Remove the spa 

cover and allow the water to cool down, then shut power off and power 

your spa up again to reset the system.

Prr

A problem is detected with the temperature probe.  

Call your dealer or service supplier.

AOH

Temperature inside the spa skirt is too high, causing the internal 

temperature in the in.xe to increase above normal limits. 

Open skirt and wait until error clears.

OH

The water temperature in the spa has reached 108°F (42°C).  

Do not enter the water! Remove the spa cover and allow the water to 

cool down to a lower temperature. Call your dealer or service supplier if 

problem persists.

FLO

The system does not detect any water flow while the primary pump is 

running. Check and open water valves. Check for water level.  

Clean filter. If the problem persists, call your dealer or service supplier.

rLy 

The system has detected a stuck relay error in in.xe.  

Call your dealer or service supplier.

UPL 

No low level configuration software has been installed into the system.

Call your dealer or service supplier.

K

ey 2 

         (2-Pump/Blower System)

Press 

Key 2

 to turn Pump 2 on at high speed. Pressing a sec- 

ond time turns blower on. A third press turns Pump 2 off but  

leaves blower on. A final press turns blower off. A built-in 

timer automatically turns Pump 2/blower off after 20 minutes, 

unless Pump 2/blower has been manually deactivated first.

 

The “Pump 2” indicator 

 

lights up when Pump 2 is on.

The “Blower” indicator 

lights up when blower is on.