* When switched on, the device performs a Lamp Test; the display and LEDs will flash for several
seconds to check that they all function correctly.
*
To activate the LOC function: -
enter the “Basic Commands” menu by pressing the key
set
.
-
press keys
and
within 2 seconds
.
If the LOC function is
Active
and you try to enter the “Programming” menu, the text LOC
appears. If this happens, the parameters are still displayed but cannot be edited.
To disable the keypad lock, repeat the aforementioned procedure.
Reduced SET / Economy LED
Flashing:
economy Setpoint active
Quick flashing: access to level2 parameters
Off:
otherwise
Compressor LED
Permanently on: compressor active
Flashing:
a delay, a protection or a
locked start-up
Off:
otherwise
Defrost LED
Permanently on: defrost active
Flashing:
manual or D.I. activation
Off:
otherwise
Alarm LED
Permanently on: alarm active
Flashing:
alarm acknowledged
Off:
otherwise
HEAT status LED
Permanently on: compressor in HEAT
Off:
otherwise
NOT USED
°C LED
Permanently on: °C setting (dro = 0)
Off:
otherwise
°F LED
Permanently on: °F setting (dro = 1)
Off:
otherwise
LEDs