GelPads 

 

Always store the GelPads in the provided resealable pouch to prevent drying out.  

 

Store GelPads in a cool, dry place until next use.  

 

The GelPads are for single person use only. 

 

When the GelPad loses adhesiveness, dries out, or becomes less effective replace it with a new GelPad. 

 

Do not fold GelPad. 

Reordering and Replacing Parts 

You will likely need more GelPads over time.  Only use ELITONE GelPads with the device. To order 
replacement GelPads visit 

www.elitone.com

 or call 

1‐978‐435‐4324

.  If you lose or damage one of the other 

parts or accessories contact customer service to obtain a replacement. 

Description of Symbols 

 

Caution!  Consult User Manual 

 

Storage Temperature Limits 

Содержание CAD-1114

Страница 1: ...Regain Control Regain Confidence User Manual Visit elitone com start for additional information and videos about getting started with ELITONE...

Страница 2: ...nce during treatment Treatment Light Solid Orange No Light Blinking Orange Contract Relax Paused Intensity Lights Tap to Decrease Intensity GelPad Cable Port Battery Light Constant Green Blinking Gree...

Страница 3: ...les Electrical muscle stimulation is a therapy that delivers a small electric current to the pelvic floor muscles Electrical muscle stimulation has been used for more than forty years however it is tr...

Страница 4: ...should be spaced throughout the week and the intensity should be at the highest level that is comfortably tolerable In time as you become familiar with the treatment you should strive to increase the...

Страница 5: ...y retention extra urethral incontinence or overflow incontinence Conductive intra uterine devices IUD Coil or metal implants in the abdominal or pelvic area including the hip and lumbar spine Warnings...

Страница 6: ...he device should not be used while driving operating machinery or any other activity in which involuntary muscle contraction may put the user at risk Use only with ELITONE GelPads Use only with ELITON...

Страница 7: ...fingers while the Controller is on Do not use more than once per day or at an intensity that exceeds your comfort level Treatment should not cause undue discomfort or muscle fatigue Turn the Controll...

Страница 8: ...Information section of this User Manual for additional information Consult your healthcare provider before using the device if o You have any serious illness or injury not mentioned in this guide o Yo...

Страница 9: ...uttons a user display a rechargeable battery and connection points for the GelPad Cable and Charging Cable 2 GelPad EE 1002 Packaged Separately The patented GelPad lightly adheres to the skin and allo...

Страница 10: ...into a standard 5 volt USB jack 5 Storage Case EA 1004 Accessory The collapsible case provides an elegant and convenient way to store the Controller Belt Clip cables and tear off Quick Reference Guide...

Страница 11: ...eatment Treatment Light Solid Orange No Light Blinking Orange Contract Relax Paused Intensity Lights Tap to Decrease Intensity Patient Cable Port Battery Light Constant Green Blinking Green Blinking R...

Страница 12: ...The device cannot be used when the battery is low or while charging Remove the USB Charging Cable prior to use The fully charged device can deliver at least two treatment sessions depending on the se...

Страница 13: ...n the figures The top portion should be low on the pubic bone area Firmly press and ensure that all four sticky regions are adhered to the skin Note initially you may need to readjust to understand th...

Страница 14: ...ons to adjust the intensity level until you feel strong tolerable muscle contractions There are 35 intensity levels The blue light changes with every 5 intensity levels The first light corresponds to...

Страница 15: ...e treatment and or adjust intensity For comfort the treatment automatically resumes at a lower intensity The device will turn off after 30 seconds in pause mode if no additional buttons are pressed 7...

Страница 16: ...skin Internally you will feel tightening and possibly a raising of the pelvic floor muscles You control the intensity with the Controller so set it to a tolerable level The treatment should never be...

Страница 17: ...es can I reuse the GelPad and how will I know when to replace it A If stored in the sealable pouch the GelPad should last 3 treatments Replace the GelPad if you notice a reduction in adhesiveness or t...

Страница 18: ...TONE we recommend starting use at a relatively low level of muscle contraction Then as you become familiar with the treatment increase the treatment intensity We also recommend spacing apart your trea...

Страница 19: ...respond to the treatment and therefore how long you should continue depends on factors including your symptom severity the treatment intensity higher is better your compliance with the recommended 4...

Страница 20: ...he end of each 6 seconds of stimulation A That part of the stimulation is intended to relax the bladder and may treat urge incontinence symptoms Q How is this different from a general use TENS or elec...

Страница 21: ...g when I increase the intensity GelPad dried out or damaged Replace GelPad GelPad not positioned properly Turn off the device shift the GelPad forward or backward one inch and check intensity Poor con...

Страница 22: ...Customer Service if the problem persists Caring for the Product Controller Cables and Belt Clip Do not allow the Controller or cables to get wet or be left in excessive sunlight Wipe with slightly dam...

Страница 23: ...less effective replace it with a new GelPad Do not fold GelPad Reordering and Replacing Parts You will likely need more GelPads over time Only use ELITONE GelPads with the device To order replacement...

Страница 24: ...ent according to IEC 60601 1 Manufacturer Recycle the device according to local regulation IP22 Ingress Protection Rating Protected against access to hazardous parts with a finger and against vertical...

Страница 25: ...out the specified limits of temperature being exceeded This product is not suitable for use in an oxygen rich environment This product is not suitable for sterilization Protected against ingress as pe...

Страница 26: ...orage and Transportation Temperature 5 to 27 C 41 to 80 F 5 to 27 C 41 to 80 F Humidity 15 95 RH non condensing 10 95 RH non condensing Atmospheric Pressure 50 106 kPa 50 106 kPa Battery Charging and...

Страница 27: ...to a power supply with the following outputs Output Voltage 5V DC nominal Output Current 0 5A 500 mA Output Connector Micro B USB Connector Expected Service Life Controller and Cables 3 years GelPads...

Страница 28: ...elow for compliance details Warning Use of this device near other equipment should be avoided because it could result in improper operation If such use is necessary this device and the other equipment...

Страница 29: ...s B ELITONE is suitable for use in all establishments including domestic and those directly connected to the public supply network that supplies buildings used for domestic purposes Table 2 Guidance a...

Страница 30: ...Environment Guidance Radiated RF IEC 61000 4 3 10 V m 80 MHz to 2 7 GHz 10 V m 80 MHz to 2 7 GHz Portable and mobile RF communications equipment should be used no closer to any part of ELITONE includi...

Страница 31: ...nd people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot...

Страница 32: ...24 Made in the USA Manufactured and Distributed by Elidah Inc 810 Main St Monroe CT USA Copyright 2020 Elidah Inc All rights reserved ELITONE is a trademark of Elidah Inc US Pats 9 623 231 10 035 016...

Отзывы: