MASTER AND SLAVE / NO TIMER

MASTER

1. Connect pin #2 of J2 Master to pin #2 of J2 Slave.
2. Connect pin #1 of J2 Master to pin #1 of J2 Slave.
3. Place both timer switches on “OFF” positions.

IN ORDER FOR THE FOLLOWING OPERATION TO OCCUR, FOLLOW THE INSTRUCTIONS.

EXAMPLE:

There is a double gate, the entry gate is to be opened with a radio transmitter and

the exit gate with a free exit loop. Only one safety loop system is to open both gates, and a
fire department switch should open both gates at the same time.
1. Connect the radio receiver to entry gate only.
2. Connect the exit loop to exit gate only.
3. Connect the safety loop to entry and exit gates.
4. Connect the fire department switch to entry and exit gates.

ON

OFF

TIMER

60       0

SLAVE

ON

OFF

TIMER

60       0

10    8     6     4     2

9     7     5     3     1

10    8     6     4     2

9     7     5     3     1

MASTER J2

SLAVE J2

PLACE 2 LOW VOLTAGE WIRES

BETWEEN OPERATORS

PARTIAL MASTER & INDIVIDUAL CONTROL

11

115 Volt

115 Volt

 

Содержание Sl-3000 series

Страница 1: ...OPYRIGHT 1988 BY ELITE ACCESS SYSTEMS INC www eliteaccess com HIGH TRAFFIC COMMERCIAL SLIDE GATE OPERATORS INSTALLATION INSTRUCTIONS MANUAL BOOK FOR ARCHITECTS GENERAL CONTRACTORS DEALERS SL 3000 SERI...

Страница 2: ...F INSTALLATIONS 4 HOW TO CONNECT THE CHAIN FOR DIFFERENT TYPES OF INSTALLATIONS 5 CEMENT WORK 6 DISTANCE BETWEEN THE OPERATOR AND GATE 7 CHOOSING MOVEMENT DIRECTION 7 HOW TO CONNECT POWER 120V 8 ADJUS...

Страница 3: ...d the installation of a stop or catch post in front of the gate s path as shown in Fig A To do so will cause the gate to hit the post in certain instances Elite only recommends installation of catch r...

Страница 4: ...talled Each sign is made with fastening holes in each corner and should be permanently secured in a suitable manner Also the warning sticker should be placed on the operator so it is clearly visible M...

Страница 5: ...TYPES OF INSTALLATIONS FRONT INSTALLATIONS 4 REAR INSTALLATIONS CEILING MOUNT UNDERGROUND PARKING Reason Space efficient chain is not visible Reason Chain is not visible Reason Cost efficient...

Страница 6: ...ns shown in picture B at the right Weld front bracket with gate in open position Weld rear bracket with gate in closed position Cut the cover by 171 2 Make sure the sprocket box is sealed 5 HOW TO CON...

Страница 7: ...D AND GATE 6 1 2 x 31 2 RED HEAD BOLT CONCRETE BED BELL BOX 3 4 PVC 24 22 20 12 12 8 10 24 24 6 24 Suggested installation for dirt ground The measurements depend on the type of ground ie asphalt cemen...

Страница 8: ...MOVEMENT DIRECTION MIN OF 4 SPACE BETWEEN GATE SPROCKET 7 INCORRECT INSTALLATION CORRECT INSTALLATION INCORRECT INSTALLATION CORRECT INSTALLATION OPEN THE ELECTRIC BOX Plug the motor wires to left op...

Страница 9: ...ndicates an estimated 1 of gate traveling distance BLACK 115VAC WHITE NEUTRAL GREEN GROUND SUGGESTION Once you are through wiring hook ups you may want to seal all open holes with silicon or another s...

Страница 10: ...on Too sensitive if the gate stops or reverses by itself Not sensitive enough if the gate hits an object and does not stop or reverse CAUTION If the power supply to the gate operator is less than 99 v...

Страница 11: ...e 2 Turn the timer pod in the slave gate operator all the way counter clockwise 3 For time range automatic close adjustment use Master timer only 4 Caution Do not shut off any of the two timers Place...

Страница 12: ...gate with a free exit loop Only one safety loop system is to open both gates and a fire department switch should open both gates at the same time 1 Connect the radio receiver to entry gate only 2 Conn...

Страница 13: ...sure each push button is dry contact and there are no jumper wires between them 10 8 6 4 2 9 7 5 3 1 1 2 Master Slave Opening orders See Master Slave section 3 4 Output for Disconnecting Switch If thi...

Страница 14: ...er 1 2 3 4 5 6 7 8 9 10 SAFETY LOOP DIGITAL LOCK EXIT LOOP PHOTO CELL RADIO RECEIVER FIRE DEPT 1 2 STRIKE OPEN 3 4 SAFETY LOOP 5 6 EXIT LOOP 7 8 RADIO REC 8 9 10 POWER ON OPEN RELAY RESET MOTOR GATE L...

Страница 15: ...g Suggested Safety Loop Installation WIRE SPECIFICATIONS Follow the manufacturer s instructions Wire has to be wrapped inside the groove three times Once you have completed the process fill up the gro...

Страница 16: ...l 6 sec POWER BACK UP OPTION A In case of power failure the gate opens automatically one time and stays open when power is restored the operator returns to normal condition OPTION B In case of power f...

Страница 17: ...rocks dirt etc 1 The gate is too heavy 3 The gate is hitting a wall or any other object 4 The gate has one or more broken wheels 5 A car has hit the gate and the gate is off of its track Pull out 2 pl...

Страница 18: ...4 SAFETY LOOP 5 6 EXIT LOOP 7 8 RADIO REC 8 9 10 POWER ON OPEN RELAY RESET MOTOR GATE LOCKED ELEC BRAKE OPEN RELAY RESET MOTOR If the gate is not moving in any direction and the reset motor light is o...

Страница 19: ...SL 3000 PARTS 18 A H 110 Q003 Q004 Q005 Q006 Q008 Q009 Q010 Q013 Q014 Q015 Q016 Q017 Q018 Q020 Q021 Q022 Q023 Q025 Q026 Q027 Q028 Q029 Q030 Q031 Q032 Q033 Q114 Q101...

Страница 20: ...BOX Q025 MOTOR PULLEY Q026 CRANK INPUT Q027 MOTOR CAPACITOR Q028 CRANK Q029 LIMIT SWITCH Q030 LIMIT SWITCH CHAIN Q031 LIMIT SWITCH SHAFT Q032 LIMIT SWITCH NUTS Q033 LIMIT SWITCH SPROCKET Q101 LIMIT S...

Страница 21: ...BLE PRODUCTS KEY SWITCH OUTDOOR DIGITAL LOCK SAFETY LOOP KEY STATION CARD READER REMOTE CONTROL SYSTEM INDOOR INTERCOM SPEAKER OUTDOOR INTERCOM SPEAKER OUTDOOR DIGITAL LOCK WITH INTERCOM THREE PUSH BU...

Страница 22: ...r installed in such a way which to prevent small children or any other persons from being able to stand hang or climb on the electric gate Picture A Warning Sign 4 6 Power Wheels A SR1 Rubber Bumper 5...

Отзывы: