MASTER AND SLAVE WITH TIMER
10
MASTER
115 Volt
115 Volt
1. Connect pin #1 of J2 Master to pin #1 of J2 Slave.
Connect pin #2 of J2 Master to pin #2 of J2 Slave.
Connect pin #6 of J2 Master to pin #8 of J2 Slave.
Connect pin #5 of J2 Master to pin #7 of J2 Slave.
2. Turn the timer pod, in the slave gate operator, all the way counter clockwise.
3. For time range automatic close adjustment, use Master timer only.
4. Caution! Do not shut off any of the two timers. Place the timer switch on “ON” position only.
ON
OFF
TIMER
60 0
SLAVE
ON
OFF
TIMER
60 0
10 8 6 4 2
9 7 5 3 1
10 8 6 4 2
9 7 5 3 1
MASTER J2
SLAVE J2
PLACE 4 LOW VOLTAGE WIRES
BETWEEN OPERATORS
For time range automatic close adjustment, use Master timer only.