Symptom

Possible cause

Action

Fluctuating 

water 

temperature

(continued)

Hot water 

temperature too high

Ensure hot water supply temperature is below 

65ºC (minimum 55ºC for stored water and 

50ºC for combination boilers).

Communications 

issue

Check data cable connections and that there 

is no visible damage.

Combination boiler 

unable to meet 

demand

Check if another outlet in the property is 

being used at the same time. 
Check that the hot water temperature is stable 

at another high flowing outlet (e.g. bath hot 

tap - run at maximum flow rate), additionally 

run a cold outlet at 1/3 of a maximum flow 

rate. If the same issue is evident on these 

outlets, contact your boiler manufacturer.

Temperature 

too low

Low hot water 

temperature

Check that domestic hot water temperature 

is a minimum of 55ºC for stored water and 

50ºC for combination boilers.

Logic Module 

temperature setting 

too low

Maximum temperature is set to a factory 

default of 45ºC. To adjust refer to the important 

information section (Safety Information) and 

Controller Commissioning Instructions in the 

Smart Shower Installation Guide. 

Temperature 

too low - 

Controller 

temperature 

ready display 

does not 

stabilise

Hot water supply 

issue

Check another hot water outlet to ensure that 

hot water is available.

Mixed water supplies

Water supplies MUST be from the same source: 

MUST NOT be gravity hot and mains cold.

Unbalanced water 

supplies

For mains fed systems the cold and hot feeds 

should be as evenly balanced as possible - 

especially for HP unvented systems.

Combination boiler 

unable to meet 

demand

See same cause in 'Fluctuating Water 

Temperature' symptom.

Temperature 

too hot

Seasonal conditions

In the warmer months, the mains water 

temperature can rise to ambient level. The 

SmartValve always blends a mix of both 

hot and cold supplies therefore the output 

temperature at fully cold (controller setting) 

will always be higher than the incoming cold 

water supply.

Temperature 

too hot

Seasonal conditions 

(gravity fed systems 

only)

For installations which utilise a cold water 

storage supply (gravity fed system), the 

ambient temperature in the loft can rise to 

above 40ºC. In turn, this warms the stored 

water. Check by running a cold tap that is 

supplied from the water storage. N.B. Kitchen 

taps are normally fed from the mains water 

system.  

Symptom

Possible cause

Action

Maximum 

temperature 

setting is not to 

your preference

Settings need 

adjusting

Refer to section 'Temperature too low', possible 

cause 'Logic module setting too low'.

Controller 

remains 

illuminated after 

switching shower 

off

Poor cable 

connection

Check data cable connections are making 

good contact, are fully inserted and that there 

is no visible damage.

Object within range 

of proximity sensor 

and activating Auto 

Wake-up

Refer to Settings section for guidance on 

disabling this function.

Water flows from 

incorrect outlet 

(divert models 

only)

Outlets not 

configured

Refer to User Guide: Settings Section - 

Configuring your Outlets on page 14.

Unable to 

configure 

outlets in 

Settings menu 

Communications 

issue

Check that 2m patch lead is connected 

between SmartValve and diverter.  Refer to 

Wiring Diagram Section in the Smart Shower 

Installation Guide.

Outlets not 

configured 

Turn off the power supply to the SmartValve, 

leave isolated for at least 2 minutes. Reinstate 

power supply and then following instructions 

in the Settings Menu complete a Factory Reset, 

then proceed to Configure Outlets.

Water dripping 

from outlets 

after use

Water retention in 

shower heads

Refer to pages 10 and 11.
Descale shower heads to clear spray jets. 

High pressure (unvented) 

water system requires 

servicing

Check the user guide for the hot water system 

to verify symptoms and where required arrange 

for servicing. 

Flow shuts 

off by itself

Maximum run time 

exceeded or end of 

duration reached in app 

timer setting

Refer to pages 6 and 20.

For further information and advice refer to Smart Shower Installation Guide 
or contact the Customer Helpline.

Language 

incorrect on

controller display

Controller  

incorrectly 

commissioned 

Refer to separately supplied literature 

or visit elisabathrooms.com

24

25

Содержание intuition

Страница 1: ...User Guide intuition...

Страница 2: ...hildren shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision For further information regarding the installation of your product refer to th...

Страница 3: ...st with ease while showering The controller has a proximity sensor so as you approach or move your hand towards the controller the display wakes up and is ready to go You can disable this feature in t...

Страница 4: ...u or Settings screens you can easily return to the home screen by turning the temperature bezel 42 35 43 Warming Cooling 34 TEMPERATURE FEEDBACK DISPLAY Adjusting the Temperature From the Home screen...

Страница 5: ...hen desired outlet icon appears Selecting your Outlet Divert models only From the Home screen you can alternate between outlets by pushing and holding the lever for over 3 seconds and releasing when t...

Страница 6: ...t the head back to allow residual water to drain out The above recommendation applies to both adjustable and fixed shower heads Rotate the spray plate lever clockwise or anticlockwise to select the de...

Страница 7: ...choose the icons that represent your outlets and change the primary outlet See page 14 for details Pair a remote PAIR A REMOTE If you have purchased a remote control please refer to the separate inst...

Страница 8: ...ould be kept clear of debris to ensure the plug maintains a watertight seal The plug can be unscrewed and removed to check and clean the mechanism Cleaning the shower head To reduce the need for chemi...

Страница 9: ...he shower tab will navigate you to a menu where you will find the Handy Hints section The ShowerMe app utilises the Instabug platform this tool can be used to Report an issue suggest an improvement or...

Страница 10: ...8 9 10 6 7 4 5 Connecting to the App THE STEP BY STEP INSTRUCTION ON CONNECTING THE SHOWER Connecting to the App THE STEP BY STEP INSTRUCTION ON CONNECTING THE SHOWER 11 18 19...

Страница 11: ...off the mobile data connection in the phone s settings Select Keep WiFi Connection with No Internet where and when prompted Ensure that your phone smart device is connected to the home Wifi network tr...

Страница 12: ...normal or ECO gravity setting Seasonal conditions During the cooler months the mains water temperature drops and this will reduce the performance of combination boilers Check with your boiler manufac...

Страница 13: ...l conditions gravity fed systems only For installations which utilise a cold water storage supply gravity fed system the ambient temperature in the loft can rise to above 40 C In turn this warms the s...

Страница 14: ...antee Please see our website for full terms and conditions Subject to terms and conditions Need Help You can find Frequently Asked Questions at elisabathrooms com Speak to our Customer Service team on...

Страница 15: ...ange or modify the product specifications without prior warning Registered Trademark Aqualisa Products Limited Q5594 Part No 705735 Issue 01 Nov 21 The Flyers Way Westerham Kent TN16 1DE Customer Serv...

Отзывы: