Elimko
E-PR-200
KY-PR200-0420-0
PAGE
53/56
Figure 9.1 Computer Connection
Figure 9.2 Crossover Cable Connection
Appendix 2: Equation Creation Using Math Editor
Equation for Math Analog and Math Digital can be easily created using Math Editor. User can apply arithmetic
operators (+,-,*,/), comparison operators (>,<,>=,<=,==), constants, channel process values and miscellaneous
functions into equations. Parenthesis can be added to equations for grouping the operations, if necessary. The
most left operator in the same parenthesis has the highest precedence. Operator precedence can be changed
using parenthesis.
Home
key sets the cursor to the left most position,
End
key sets the cursor to the right most
position, key shifts the cursor one character left and key shifts the cursor one character right.
Delete
and
Back
Space
keys delete one character towards to the left or right respectively.
Clear
key clears the existing equation.
Channel process values can be included in to the equations by pressing
SOURCE
key.
RUN
key runs the equation
for testing. Pressing
OK
key saves the equation,
CANCEL
key cancels all operations.
Script
is defined in the key device used for the incorporation of equality of a team ready to function. When
pressed
Script
out the following options.
$(second):
Count of seconds indicates that the system time.
$(minute):
The system indicates that the clock match minute.
$(hour):
It displays the system time.
$(year):
Which it indicates that year on the system.
$(month):
Indicates that the system on which month.
$(day):
Indicates that the day on which the System.
$(coretemp):
The device shows the core temperature of the processor.
$(moduletemp):
The device displays the temperature of the processor module.
cj():
CJ (SlotNo, ChannelNo) is used with parameters. The channel parameters gives the cold spot temperature of
the specified slot. Slot and Channel Number should be a zero index (cj (0,0) 1.Slot channel 1 's cold spot
temperature data.).
microvolt():
Microvolts (Slotno, ChannelNo) is used with parameters. Parameters of the analog input channels of
the slot referred to as raw data the value of reading microvolts. Slot and Channel Number should be a zero index
(microvolts (0.0) 1.Slot 's channel 1' s value in microvolts is reading.).