background image

 

 E-PR-200 

PAPERLESS RECORDER 
USER MANUAL 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

RELIABLE NAME IN AUTOMATIC CONTROL 

SYSTEM AND TURN-KEY CONTRACTS 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Manufacturer / Technical Support 

Elimko Electronic Production and Control Co. Ltd. 
8. Avenue 21. Street No:16   06510 Emek- Ankara / TURKEY 
Phone: + 90 312 212 64 50 Fax: + 90 312 212 41 43 
www.elimko.com.tr e-mail:[email protected]

Содержание E-PR-200 Series

Страница 1: ...ATIC CONTROL SYSTEM AND TURN KEY CONTRACTS Manufacturer Technical Support Elimko Electronic Production and Control Co Ltd 8 Avenue 21 Street No 16 06510 Emek Ankara TURKEY Phone 90 312 212 64 50 Fax 9...

Страница 2: ...6 CHANNELS PAGE 24 6 6 1 RELAY OUTPUT CARD ADJUSTMENTS 24 6 6 2 DIGITAL OUTPUT CARD ADJUSTMENTS 25 6 6 3 ANALOG INPUT CARD ADJUSTMENTS 25 6 6 4 ANALOG OUTPUT CARD ADJUSTMENTS 27 6 6 5 ALARM ADJUSTMENT...

Страница 3: ...utput Card Calibration Page 22 Figure 6 11 Hardware Ethernet Page Obtain an IP address via DHCP 22 Figure 6 12 Hardware Ethernet Page Manual Set 22 Figure 6 13 Hardware Serial Port screen 23 Figure 6...

Страница 4: ...6 64 Analog Input page table selection 40 Figure 6 65 Archive Synchronization Page 41 Figure 6 66 Archive Backup Page 41 Figure 6 67 E MAIL Server Page 41 Figure 6 68 E MAIL Recipients Page 42 Figure...

Страница 5: ...dor from which you purchased the product Before installing and operating the controller please read the user manual thoroughly The installation and configuration of the recorder must only be performed...

Страница 6: ...annels Up to 32 Digital Output Channels Up to 18 Analog Output Channels Standard RS 485 communication port 10 100 Mbit Ethernet Port Wi Fi Optional USB Host Port 4 1 TYPE CODING E PR 200 S1 S2 S3 S4 S...

Страница 7: ...uts Max 54 Analog Inputs 16 bit isolation of channels 1000 V AC See Section 7 CONNECTION DIAGRAMS Analog Outputs 0 20 mA 0 10 V can be configured Number of analog outputs is limited to 18 Digital Inpu...

Страница 8: ...a suitable grounded metal enclosure panel This must prevent the live parts being accessible to human hands and metal tools See Section 7 CONNECTION DIAGRAMS E PR 200 does not include a power switch Th...

Страница 9: ...ea appears in blue see Figure 5 1 Figure 5 1 Trend View During normal operation the operation buttons are hidden to increase the display area Hidden operation buttons can be made visible by touching t...

Страница 10: ...etailed explanations of the menus are given in the related description of the views This button is active only in the trend view Used to increase or decrease the width of the screen This button allows...

Страница 11: ...ed in Operator Menu While in history mode process values date and time seen on the screen are the values at the time of cursor location By touching the screen the location of the cursor can be changed...

Страница 12: ...can be chosen with this parameter Desired traces can be opened or closed in Traces Menu Axis The axis of the channel to be seen on the trend can be chosen with this parameter Add Operator Message Add...

Страница 13: ...rm states of 12 channels in selected group are viewed Channel Name Process Value Alarm 1 Alarm 2 If the alarms are defined H or L is written according to alarm types Active alarms are shown with red c...

Страница 14: ...Digital View Page Operator Menu for Digital View Page is opened by pressing button To reset the totalizer of an individual source select the corresponing source name in sub menus of Reset Totalizer m...

Страница 15: ...upy two rows and due to overall row limitation some of the process groups appears intermittently 5 6 Alarm Log Figure 5 11 Alarm Log screen The last occurred and released 10000 alarms with date and de...

Страница 16: ...lizer is displayed at the top of the list Totalizer values can be scrolled by and buttons The time intervals of totalizers are defined with the Logging Source parameter of related Totalizer 5 8 Instru...

Страница 17: ...r Log Page and keys scrolls the page up and down direction see 5 2 TREND PAGE ve 5 4 DIGITAL VIEW PAGE 5 10 Digital Log Figure 5 15 Digital Log screen Source Name record date and definition of the las...

Страница 18: ...reached by either pressing MENU or LOGIN button LOGIN access does not require authentication on subsequent entries until LOGOUT is pressed from Main Menu Depending on previously defined authorization...

Страница 19: ...nication Addresses see Appendix 3 Figure 6 2 Main Menu 6 3 Device Page Figure 6 3 Device Page In Device Page Device Type and Version are shown Date and Time adjustments and factory settings reset are...

Страница 20: ...ware Page The hardware adjustments are made in this page HARDWARE Page consists of 4 tabs as Slot Ethernet Serial Port and Screen 6 5 1 Slot Adjustments ATTENTION The calibration parameter adjutment r...

Страница 21: ...ation Figure 6 9 Analog Input Card Calibration Page 50 mV Set the calibrator as a millivolt source and adjust the calibrator output 50 000 mV Apply the calibrator output to the millivolt input of the...

Страница 22: ...value of the calibration is set using the up and down keys For ease of calibration up and down keys are given as two pieces of 100 levels and 10 levels 100 steps for coarse changes 10 steps are used...

Страница 23: ...of the screen Brightness can be adjusted between 20 and 100 Screen Saver ON or OFF selectable Screen Saver Time Determines the time period after that the device starts screeen saver if no operation ta...

Страница 24: ...d Relay Output can be written by this parameter maximum length of 12 characters Description Maximum 50 characters long description Off Message Maximum 100 characters long alarm off message On Message...

Страница 25: ...to linearize the Linear Inputs while the process value is calculated Decimal Point Determines the position of decimal point The parameter can be adjusted as 0 0 0 0 00 or 0 000 Zero Span Determines p...

Страница 26: ...Thermocouple Figure 6 23 Linearization Select Input Type Resistance Thermometer Figure 6 24 Linearization Select Input Type Ohm Milivolt Miliamper or Volt ATTENTION CJ Type CJ Source and CJ temperatur...

Страница 27: ...med with using maximum 12 character Description Maximum 50 characters long description Source Determines the analog source by which the analog output is controlled Type Output type mA or Volt can be s...

Страница 28: ...IGH alarm types deviation for SLOW RATE and FAST RATE types Hysteresis Defines alarm hysteresis for LOW and HIGH alarms Latch Enable Enabling latch causes alarm on state to persist until being acknowl...

Страница 29: ...is defined for each slot analog input math analog and Modbus analog channels Name Totalizer of related channel can be named with using 12 characters Enable Determines if totalizer is active or not Per...

Страница 30: ...ach recording period option certain number of sampled values are collected depending on selected recording period Total Number Of Samples Recording Period ms 100 Filter parameter determines the way ho...

Страница 31: ...d recording settings 6 6 9 Modbus Channels Page Up to 16 MODBUS RTU channels can be configured by this page Firstly channel number is clicked from the left of the screen before starting the configurat...

Страница 32: ...Decimal Point Determines the position of decimal point The parameter can be set as 0 0 0 0 00 or 0 000 Fault Value Determines the value of the channel in fault status Unit Determines the unit Figure...

Страница 33: ...e related real time source will be active as shown below For example if Period Start and End are adjusted as Every Minute 0 5 respectively the related channel will be active in first 5 seconds of ever...

Страница 34: ...on direction can be changed by selecting Horizontal Vertical and Circular Batch Start Input The desired group is selected from 12 groups Batch Start Input of the selected group can be defined Sources...

Страница 35: ...nu Graphic Type Horizontal Vertical or Circular can be selected from the Groups menu see Figure 6 50 Figure 6 51 Figure 6 52 and Figure 6 53 show the graphical representation of the Graphic Type selec...

Страница 36: ...w process This process continues as long as the digital input is active and the process is stopped by recording the interruption of the digital input When entered into the GROUPS menu the Batch Start...

Страница 37: ...s activated Figure 6 57 shows the passivation status of the digital input and Figure 6 58 shows the case where the process number is incremented and the new process is started when the digital input i...

Страница 38: ...by pressing the button see Figure 6 59 Figure 6 60 Figure 6 61 and Figure 6 62 Trend can be watched by selecting a previously completed process and pressing Open The Stop key Stops the selected operat...

Страница 39: ...420 0 PAGE 39 56 The data stored in the device can be downloaded to the computer via USB or ETHERNET connection with the E PR 200 DATA EXPLORER program and the printer output can be retrieved A sample...

Страница 40: ...to delete all stored data archives Resetting archive causes all records to be lost irreversibly Sync Direction Sync Direction determines synchronization direction DEVICE TO DISC option transfers the...

Страница 41: ...by multiple configurable triggers such as sources and general events 6 11 1 Server Adjustments Server SMTP incoming mail server Port SMTP port number SSL Disable or Enable SSL User User Account Name P...

Страница 42: ...ed to any of the sources Figure 6 69 E MAIL Sources Page 6 11 4 Events On New Alarm ON or OFF selectable If ON is selected a new e mail is sent when an alarm occurs On New Instrument Log ON or OFF sel...

Страница 43: ...ce name Description Maximum 50 characters can be entered Additional explanation can be entered Input Source Determines PID control loop input variable the process variable to be controlled The input s...

Страница 44: ...ll affect the process variable should be in mind For instance cooling outputs causes a reverse reaction of temperature output Proportional Band Proportional band of PID loop in engineering unit Integr...

Страница 45: ...Value on TREND view screen and click PID Source on the BAR or DIGITAL view screen to open the PID CHECK window By using the set value arrows from the opened window you can change it by entering set v...

Страница 46: ...ice and used for different purposes Profile sources can be assigned as external set source for PID channels in the device Profile sources can be transmitted to other systems as reference sources using...

Страница 47: ...Elimko E PR 200 KY PR200 0420 0 PAGE 47 56...

Страница 48: ...Elimko E PR 200 KY PR200 0420 0 PAGE 48 56 ekil 6 78 6 13 1 Curves Explanations about the parameters are given below The screenshot is as given in Figure 6 79 ekil 6 79...

Страница 49: ...the desired card fix the screws again During changing or adding card device should be powered off After each new card configuration it must be registered by scanning new configuration Please see Secti...

Страница 50: ...Card Connection Diagrams 6 Channels RT ohm For TC input E CJ NTC 01 terminals supplied with the device seperately should be used Up Down 1 Channel 2 Channel 3 Channel Up Down For TC input E CJ NTC 01...

Страница 51: ...short circuited with a suitable cable Snubber consist of serially connected a capacitor 10nF 630 V and a resistance 100 1 4 W and can be used to suppress the contact noise While the contact is used fo...

Страница 52: ...All registers given in Appendix 3 can be read or write depending on access rights 5 Barcode Scanner Connection Please check Appendix 4 for detailed explanation 6 Wi Fi Indicates that the Wi Fi connec...

Страница 53: ...sing OK key saves the equation CANCEL key cancels all operations Script is defined in the key device used for the incorporation of equality of a team ready to function When pressed Script out the foll...

Страница 54: ...Addresses Modbu RTU Register addresses can be reached from MODBUS TABLE window by presing the MODBUS TABLE button in the Main Menu Digital channel grouped by slots are respresented with a single addre...

Страница 55: ...Elimko E PR 200 KY PR200 0420 0 PAGE 55 56...

Страница 56: ...e operations are Start Batch Stop Batch and Batch Name Input Barcode scanner should be configured as an USB keyboard emulator and barcode termination character should be set to horizontal tab ASCII 9...

Отзывы: