9
8.
Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL
JUNCTION BOX WITH 3 WIRES, ONE OF WHICH
(GREEN/YELLOW) SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST
ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE
MUST BE CONNECTED TO THE GROUNDING WIRE
IN YOUR HOME ELECTRICAL SYSTEM, AND IT
MUST UNDER NO CIRCUMSTANCES BE CUT OR
REMOVED.
Failure to do so can result in death or electrical
shock.
Facing the front of the range hood, remove the left
knockout and the Junction box cover and install the
conduit connector (cULus listed) in junction box.
Run 3 wires; black, white and green ,according to the
National Electrical Code and local codes and
ordinances, in 1/2" conduit from service panel to
junction box.
Connect black wire from service panel to black or red in
junction box, white to white and green to green-yellow.
Close and secure junction box cover.
9. Note:
disregard this step if the hood has been fitted with
an integralventilator.
Purchase and install a Remote ventilator (see paragraph
„Before installing the hood - Parts not supplied“ for
model reference).
10.
For non-vented (recirculating) installations ONLY:
Install one charcoal filter.
11.
Assemble the canopy with the integral ventilator housing
(chimney structure):
a.
Remove the grease filter (see also Care & Use
section - Charcoal filter).
b.
Thread completely the lower part of the hood onto
the integral ventilator housing rails.
Note: control panel on canopy and electronic box
on chimney structure should be on the same side.
c.
Make alla cable connections: