Replacing Components
- 80 -
RED/LIMAX44 RED connector has to be disconnected from the Safe Box. The Safe Box is dismounted from the
fixture and then the replacement device is fixed to the same fixture.
WARNING!
Take care the rated speed of the replacement device fits the rated
speed of the lift!
Now the connector of LIMAX33 RED/LIMAX44 RED is reconnected to the Safe Box. Then the connector of the
replacement device is connected to its counterpart on the customer’s side (resp. all electrical connections are
connected in case of open wire ends on customer’s side).
These installations are usually carried out on the cabin roof. Then the technician leaves the cabin roof in order
to switch the lift system back on.
The appropriate safety measures must be followed during installation (reduced shaft head / shaft pit).
The further procedures correspond to the learn trip described in chapter 9.3 and 10.4.2.
15.3.2
Dismantling an intact Safe Box
If an intact Safe Box is dismounted, it is not allowed to use the device in another lift. The reason is that at com-
missioning of a Safe Box in a lift where this specific device was not installed before it has to be ensured that the
Safe Box is in pre commissioned mode and that the temporary reference position are erased.
At the moment, the latter can be ensured only at ELGO Batscale AG.
The dismounted Box has to be sent back to ELGO Batscale AG. There it will be reset and it will be checked if all
safety relevant values (shaft image and temporary reference positions) are really erased.
16
Cleaning
WARNING!
The device can only be cleaned with a damp cloth, do not use aggres-
sive cleanser!