ATTENTION!
THIS OPERATION MUST BE CARRIED OUT ONLY BY QUALIFIED
PERSONNEL, AUTHORIZED TO PERFORM GAS ADJUSTMENT WORKS.
9.1.
In order to correctly regulate the minimum flow of gas, it is necessary to:
-
burn the burner;
-
turn the crane to the minimum position;
-
remove the knob and adjust the burner on a small stable flame with the help of adjusting screw, located on the side of
the crane rod;
Adjusting screw
-
check whether the burner does not fade when the crane is rotated from its maximum position to the minimum.
-
When using liquefied petroleum gas, the adjusting screw must be twisted to the stop.
-
The main air burner does not need to be regulated.
10.1.
Near each control knobs the position of corresponding gas burner is indicated, as well as the symbols of minimum
and maximum flame.
maximum flame
minimum flame notification of burner position
10.2.
The flame of burner is regulated by the control knob, corresponding to it.
10.3
All cooking surfaces are equipped with system of electric ignition. To activate the selected burner, you need to press
the control knob, and turn it counterclockwise to the maximum flame position and hold for a few seconds.
10.4
To turn off the burner, turn the knob clockwise until it stops.
10.5
If the burner flames fade, turn the knob to the “Off” position and repeat the operation not earlier than 1 minute
10.6
To ensure optimal operation of the hob, you need:
-
to use cookware according to the size of burners pursuant to the table
Type of burner
Diameter of cookware, mm
Speed action
220-260
Half-speed action
180-220
Auxiliary
120-180
9
.
REGULATION OF MINIMUM GAS CONSUMPTION.
10.
INSTRUCTIONS FOR USE AND CARE OF THE
HOB
.