7. CONNECTION TO THE POWER NETWORK.
ATTENTION!
THE HOB MUST NECESSARILY BE GROUNDED.
7.1.
The connection of appliance to the power supply must be carried out by a qualified specialist, subject to the rules and
regulations in force.
7.2.
The hob has I class of electrical safety, and is designed for connecting to 220-240 V power supply, 50 Hz.
7.3.
Before connecting, it is necessary to check the conformity of electrical parameters of the hob (required data is indicated
on the factory nameplate placed below the appliance) to the electric network.
7.4.
The hob is equipped with network cable with plug. The socket must match the size of plug and have ground contacts.
7.5.
The socket must be in an easily accessible place for quick access to the plug.
7.6.
If the appliance is not used for a long time, remove the plug from the socket.
ATTENTION!
THIS OPERATION MUST BE CARRIED OUT ONLY BY QUALIFIED
PERSONNEL WHO HAVE PERMISSION TO PERFORM WORKS ON THE
ADJUSTMENT OF GAS EQUIPMENT
8.1
. To adjust the hob to the type of gas other than the prescribed one (and indicated below the hob), you need to change
the burner nozzles, for this:
-
remove the grate;
-
remove the cutting deck and the cutter of flame;
-
unscrew nozzles, using the appropriate end-piece tubular key and replace them with appropriate nozzles for a new type
of gas (included).
Nozzle
-
place all parts in place by performing the abovementioned steps in reverse order;
8.2.
Upon completion of reconfiguration operations, it is necessary to change the type of gas on the label on the
bottom of appliance to the appropriate one.
8.3.
If the pressure of used gas differs (or varies) from the one indicated on the nameplate, a suitable pressure
regulator must be installed in accordance with local gas network standards.
8
.
RECONFIGURATION TO ANOTHER TYPE OF GAS.