USER MANUAL RPS/M - 62000582 Rel.2.0
–
12/10/2018
3.3.3.
Limitation Setting
Both peak and average limitation can be set via serial command. Limits must be included in the
range [500,4095]. Values less than 500 are considered 500 by default (minimum value).
The factory values for both limitations are 4095. For further information please read the
programming manual.
3.4.
OUTPUT SWITCH
It’s possible to open or close the output
switch both by serial command and digital input. Before
opening the switch, the output voltage is switched to zero to safeguard the switch. Similarly, the
closing is done with zero voltage. Afterwards, the output will reach the set value through a voltage
ramp (set via serial commands).
The turn off of the output switch does not allow operations on the EUT connections.