21
USER MANUAL RPS/M - 62000582 Rel.2.0
–
12/10/2018
6.
TECHNICAL SPECIFICATIONS
6.1.
DATA SHEET
MODEL
1K
2K5
5K
10K
Power supply
1PH 230Vac ±10%
1PH 230Vac ±10%
1PH 230Vac ±10%
3PH+N 400Vac ±10%
Power
1000VA
2500VA
5000VA
10000VA
International
Protection
IP20
IP20
IP20
IP20
Pollution degree
3
3
3
3
Overvoltage
category
Category II
Category II
Category II
Category II
Maximum input
current
7,5 Arms
18 Arms
35 Arms
24 Arms / 41 Arms
on neutral
Input frequency
50Hz
–
60Hz
50Hz
–
60Hz
50Hz
–
60Hz
50Hz
–
60Hz
Output type
Single phase
Single phase
Single phase
Single phase
Output isolation
Not isolated
Not isolated
Not isolated
Not isolated
Maximum output
voltage
300 V
300 V
300 V
300 V
Maximum output
current (RMS)
3,3 A
8,3 A
16,7 A
30,1 A
Maximum output
inrush current (3 sec)
6,9 A
16,7 A
33,4 A
64,3 A
Output frequency
range
DC, 10Hz
–
80Hz
(1)
DC, 10Hz
–
80Hz
(1)
DC, 10Hz
–
80Hz
(1)
DC, 10Hz
–
80Hz
(1)
Dimensions
2U: 450:440
(2)
4U: 450:540
(2)
4U: 450:540
(2)
6U: 450:540
(2)
Weight
12 kg
25 kg
25 kg
48 kg
Protections
OVP,UVP,OTP,OCP
OVP,UVP,OTP,OCP
OVP,UVP,OTP,OCP
OVP,UVP,OTP,OCP
Operating
temperature
0 / +35 °C
0 / +35 °C
0 / +35 °C
0 / +35 °C
Storage temperature
-20 / +70 °C
-20 / +70 °C
-20 / +70 °C
-20 / +70 °C
RS232
Yes
Yes
Yes
Yes
RS485
Option
Option
Option
Option
LAN
Option
Option
Option
Option
Output DC
Yes
Yes
Yes
Yes
Digital IO
Yes
(3)
Yes
(3)
Yes
(3)
Yes
(3)
Safety certification
EN 61010-1
EN 61010-1
EN 61010-1
EN 61010-1
EMC certification
EN 61000-6-2
(4)
EN 61000-6-4
(5)
EN 61000-6-2
(4)
EN 61000-6-4
(5)
EN 61000-6-2
(4)
EN 61000-6-4
(5)
EN 61000-6-2
(4)
EN 61000-6-4
(5)
(1)
Frequency can be set up to 320Hz in derating power mode.
(2)
Dimension with connectors.
(3)
See section 4.2.
(4)
Immunity: industrial environment.
(5)
Emission: industrial environment.
Содержание RPS/M/10K
Страница 23: ...22 USER MANUAL RPS M 62000582 Rel 2 0 12 10 2018 6 2 MECHANICAL DRAWINGS 6 2 1 RPS M 1K without connector ...
Страница 24: ...23 USER MANUAL RPS M 62000582 Rel 2 0 12 10 2018 6 2 2 RPS M 2K5 AND RPS M 5K with connector ...
Страница 47: ...22 USER MANUAL RPS M 62000582 Rel 2 0 12 10 2018 6 2 DISEGNI MECCANICI 6 2 1 RPS M 1K senza connettori ...
Страница 48: ...23 USER MANUAL RPS M 62000582 Rel 2 0 12 10 2018 6 2 2 RPS M 2K5 e RPS M 5K con connettori ...