AMS90/1
APPLICATION MANUAL
15P0056B1
13/17
... cont.
TERMINAL BOARD DESCRIPTION
TERMINAL BOARD DESCRIPTION
POWER TERMINAL BOARD
POWER TERMINAL BOARD
21
22
D.C. supply output for armature winding.
Positive polarity on term. 22
.
23
24
Single-phase supply (STANDARD 400V
AC
) for AC/DC conversion bridge.
If required, 415/440V
AC
supply voltages are available.
SUPPLY TERMINAL BOARD
SUPPLY TERMINAL BOARD
25
26
Single-phase supply (STANDARD 230/400V
AC
– 50Hz with voltage change jumper).
Supply frequency 60Hz with presetting by closing the two contacts of dip-switch SW1.
Note: If required, 415/440V
AC
supply voltages are available.
10VA
27
28
Single-phase supply (STANDARD 400V
AC
max) for inner rectifier for field winding.
400V
AC
max
2A max
29
30
D.C. supply output for field winding.
Positive polarity on term. 29
.
360V
DC
max
2A max
TECHNICAL DATA TABLE
TECHNICAL DATA TABLE
AMS90/1 size
Rated
current
(A)
Max. armature
voltage
(V)
Output electric
power
(kW)
Motor power
(
η
=0.8)
(HP)
AMS90/1.10
supp. 230V
AC
10
170
1.7
1.8
AMS90/1.10
supp. 400V
AC
10
280
2.8
3
AMS90/1.20
supp. 230V
AC
20
170
3.4
3.7
AMS90/1.20
supp. 400V
AC
20
280
5.6
6
AMS90/1.30
supp. 230V
AC
30
170
5.1
5.5
AMS90/1.30
supp. 400V
AC
30
280
8.4
9.1